English
Related papers

Related papers: Development of a high-rate capable DLC-RPC based o…

200 papers

Understanding the noise characteristics of high quantum efficiency silicon-based ultraviolet detectors, developed by the Microdevices Lab at the Jet Propulsion Laboratory, is critical for current and proposed UV missions using these…

The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of…

A large volume Time Projection Chamber (TPC) is being considered for the central charged particle tracker for the detector for the proposed International Linear Collider (ILC). To meet the ILC-TPC spatial resolution challenge of ~100…

Instrumentation and Detectors · Physics 2008-11-26 K. Boudjemline , M. S. Dixit , J. -P. Martin , K. Sachs

A new design of highly granular hadronic calorimeter using Glass Resistive Plate Chambers (GRPCs) with embedded electronics has been proposed for the future International Linear Collider (ILC) experiments. It features a 2-bit threshold…

Neutrinos, elusive and abundant, interact weakly with matter, making detection challenging. This thesis explores neutrino physics, focusing on mass hierarchy and oscillations, with emphasis on India's upcoming INO facility. The Iron…

Instrumentation and Detectors · Physics 2025-07-31 Tanay Dey

In experiments searching for rare signals, background events from the detector itself are some of the major factors limiting search sensitivity.Screening for ultra-low radioactive detector materials is becoming ever more essential. We…

Instrumentation and Detectors · Physics 2021-12-24 Haiyan Du , Chengbo Du , Karl Giboni , Ke Han , Shengming He , Liqiang Liu , Yue Meng , Shaobo Wang , Tao Zhang , Li Zhao , Jifang Zhou

Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas…

The requirement of high rate capability for operation at LHC, led 20 years ago to the achievement of Resistive Plate Chambers operated in avalanche mode, thanks to the introduction of new gas mixtures and to the development of the Front-End…

Instrumentation and Detectors · Physics 2017-06-28 A. Paoloni , A. Mengucci , M. Spinetti , M. Ventura , L. Votano

A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an…

Instrumentation and Detectors · Physics 2018-07-16 M. M. Aggarwal , Z. Ahammed , S. Aiola , J. Alme , T. Alt , W. Amend , A. Andronic , V. Anguelov , H. Appelshäuser , M. Arslandok , R. Averbeck , M. Ball , G. G. Barnaföldi , E. Bartsch , R. Bellwied , G. Bencedi , M. Berger , N. Bialas , P. Bialas , L. Bianchi , S. Biswas , L. Boldizsár , L. Bratrud , P. Braun-Munzinger , M. Bregant , C. L. Britton , E. J. Brucken , H. Caines , A. J. Castro , S. Chattopadhyay , P. Christiansen , L. G. Clonts , T. M. Cormier , S. Das , S. Dash , A. Deisting , S. Dittrich , A. K. Dubey , R. Ehlers , M. Engel , F. Erhardt , N. B. Ezell , L. Fabbietti , U. Frankenfeld , J. J. Gaardhøje , C. Garabatos , P. Gasik , Á. Gera , P. Ghosh , S. K. Ghosh , P. Glässel , O. Grachov , A. Grein , T. Gunji , H. Hamagaki , G. Hamar , J. W. Harris , P. Hauer , J. Hehner , E. Hellbär , H. Helstrup , T. E. Hilden , B. Hohlweger , M. Ivanov , M. Jung , D. Just , E. Kangasaho , R. Keidel , B. Ketzer , S. A. Khan , S. Kirsch , T. Klemenz , S. Klewin , A. G. Knospe , M. Kowalski , L. Kumar , R. Lang , R. Langoy , L. Lautner , F. Liebske , J. Lien , C. Lippmann , H. M. Ljunggren , W. J. Llope , S. Mahmood , T. Mahmoud , R. Majka , P. Malzacher , A. Marín , C. Markert , S. Masciocchi , A. Mathis , A. Matyja , M. Meres , D. L. Mihaylov , D. Miskowiec , J. Mitra , T. Mittelstaedt , T. Morhardt , J. Mulligan , R. H. Munzer , K. Münning , M. G. Munhoz , S. Muhuri , H. Murakami , B. K. Nandi , H. Natal da Luz , C. Nattrass , T. K. Nayak , R. A. Negrao De Oliveira , M. Nicassio , B. S. Nielsen , L. Oláh , A. Oskarsson , J. Otwinowski , K. Oyama , G. Paić , R. N. Patra , V. Peskov , M. Pikna , L. Pinsky , M. Planinic , M. G. Poghosyan , N. Poljak , F. Pompei , S. K. Prasad , C. A. Pruneau , J. Putschke , S. Raha , J. Rak , J. Rasson , V. Ratza , K. F. Read , A. Rehman , R. Renfordt , T. Richert , K. Røed , D. Röhrich , T. Rudzki , R. Sahoo , S. Sahoo , P. K. Sahu , J. Saini , B. Schaefer , J. Schambach , S. Scheid , C. Schmidt , H. R. Schmidt , N. V Schmidt , H. Schulte , K. Schweda , I. Selyuzhenkov , N. Sharma , D. Silvermyr , R. N. Singaraju , B. Sitar , N. Smirnov , S. P. Sorensen , F. Sozzi , J. Stachel , E. Stenlund , P. Strmen , I. Szarka , G. Tambave , K. Terasaki , A. Timmins , K. Ullaland , A. Utrobicic , D. Varga , R. Varma , A. Velure , V. Vislavicius , S. Voloshin , B. Voss , D. Vranic , J. Wiechula , S. Winkler , J. Wikne , B. Windelband , C. Zhao

With the development of the circular collider, it is necessary to make accurate physics experimental measurements of particle properties at higher luminosity $Z$ pole. Micro-pattern gaseous detectors (MPGDs), which contain Gaseous Electron…

Instrumentation and Detectors · Physics 2021-09-22 Zhiyang Yuan , Huirong Qi , Yue Chang , Ye Wu , Hongyu Zhang , Jian Zhang , Yuanbo Chen , Yiming Cai , Yulan Li , Zhi Deng , Hui Gong

Performances of several single gap (gas gap 2 mm) prototype Resistive Plate Chambers (RPC) made of high resistive ({\rho} \sim 1010 - 1012 {\Omega} cm) bakelite, commercially available in India have been studied in recent times. To make the…

Instrumentation and Detectors · Physics 2015-06-05 S. Biswas , Purba Bhattacharya , S. Bhattacharya , S. Bose , S. Chattopadhyay , N. Majumdar , S. Mukhopadhyay , S. Saha , Y. P. Viyogi

The Time Projection Chamber is the main tracking and particle identification detector of the ALICE experiment. The high luminosities delivered by the CERN LHC in Run 2 (2015-2018) posed new challenges in terms of detector performance and…

Instrumentation and Detectors · Physics 2019-09-10 Ernst Hellbär

Resistive electrodes are used in gaseous detectors to quench electrical discharges. This helps to protect delicate electrodes and readout electronics and to improve the stability of the detector operation. An RPWELL is a THGEM-based WELL…

Instrumentation and Detectors · Physics 2024-06-14 Abhik Jash , Luca Moleri , Andrea Tesi , Shikma Bressler

Radial time projection chambers (TPC), already employed in the search for rare phenomena such as light Dark Matter candidate, could provide a new detection approach for the search of neutrinoless double beta decay ($\beta\beta0\nu$). The…

Pressurized drift-tube chambers are efficient detectors for high-precision tracking over large areas. The Monitored Drift-Tube (MDT) chambers of the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) reach a spatial…

Instrumentation and Detectors · Physics 2016-10-04 B. Bittner , J. Dubbert , S. Horvat , O. Kortner , H. Kroha , F. Legger , R. Richter , S. Adomeit , O. Biebel , A. Engl , R. Hertenberger , F. Rauscher , A. Zibell

This paper studies the performance of RPCs working with a new family of environment-friendly operating gases, mainly based on Carbon Dioxide and Hydro-Fluoro-Olefins. The tests are carried out on a 2 mm gap RPC and concern the measurement…

Instrumentation and Detectors · Physics 2022-05-18 G. Proto , B. Liberti , R. Santonico , G. Aielli , P. Camarri , R. Cardarelli , A. Di Ciaccio , L. Di Stante , A. Paoloni , E. Pastori , L. Pizzimento , A. Rocchi

A large number of high-energy and heavy-ion experiments successfully used Time Projection Chamber (TPC) as central tracker and particle identification detector. However, the performance requirements on TPC for new high-rate particle…

Instrumentation and Detectors · Physics 2013-02-14 M. Poli Lener , M. Bazzi , G. Corradi , C. Curceanu , A. D'Uffizi , C. Paglia , A. Romero Vidal , E. Sbardella , A. Scordo , D. Tagnani , J. Zmeskal

Results obtained by the RPC ECOgas@GIF++ Collaboration, using Resistive Plate Chambers operated with new, eco-friendly gas mixtures, based on Tetrafluoropropene and carbon dioxide, are shown and discussed in this paper. Tests aimed to…

We propose a large-area, cost-effective Muon Telescope Detector (MTD) for the Solenoidal Tracker at RHIC (STAR) at mid-rapidity and for the next generation of detectors at a possible electron-ion collider. We utilize Multi-gap Resistive…