Related papers: Development of a high-rate capable DLC-RPC based o…
A new type of resistive plate chamber (RPC) is under development using thin-film resistive electrodes based on diamond-like carbon (DLC). Planned to be put on the path of high-intensity low-momentum muon beam of the MEG II experiment, this…
A new type of resistive plate chamber with thin-film electrodes based on diamond-like carbon is under development for background identification in the MEG II experiment. Installed in a low-momentum and high-intensity muon beam, the detector…
A novel Resistive Plate Chamber (RPC) was designed with Diamond-Like Carbon (DLC) electrodes and performance studies were carried out for 384$\,\mathrm{\mu m}$ gap configuration with a $2\,\mathrm{cm}\times2\,\mathrm{cm}$ prototype. The use…
A novel type of resistive plate chamber, based on diamond-like carbon (DLC) electrodes is under development for background identification in the MEG II experiment. The DLC-RPC is required to have a radiation hardness to mass irradiation…
We developed a novel design of a Micro Pixel Chamber ($\mu$-PIC) with resistive electrodes for a charged-particle-tracking detector in high-rate applications. Diamond-Like Carbon (DLC) thin film is used for the cathodes. The resistivity can…
Principles of operation, construction and first test results of a Dielectric Resistive Plate Chamber (DRPC) are described. The detector has shown stability of operation in the avalanche mode of gas amplfication within a wide range of…
To achieve high-resolution muography of compact targets in scenarios with complex logistical constraints, we are developing a portable muon detector system utilizing glass Resistive Plate Chambers (RPCs). Although RPCs are well understood…
The Multi-gap Resistive Plate Chamber (MRPC) is an advanced form of Resistive Plate Chamber (RPC) detector where the gas gap is divided into sub-gaps. MRPCs are known for their good time resolution and detection efficiency for charged…
The first Resistive Plate Chambers detectors were developed for cosmic ray experiments, where low rate capability, good time resolution and low cost per unit of area were needed. These same features, except for the low rate capability, were…
Single gap (gas gap 2 mm) bakelite Resistive Plate Chamber (RPC) modules of various sizes from 10 cm \times 10 cm to 1 m \times 1 m have been fabricated, characterized and optimized for efficiency and time resolution. Thin layers of…
Resistive Plate Chamber (RPC) is one of the most commonly used detectors in high energy physics experiments for triggering and tracking because of its good efficiency ($\textgreater$~90\%) and time resolution ($\sim$~1-2~ns). Generally,…
Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a…
The limitation of the detection rate of standard bakelite resistive plate chambers (RPC) used as muon detectors in the LHC experiments has prevented the use of such detectors in the high rate regions in both CMS and ATLAS detectors. One…
Large Resistive Plate Chamber systems have their roots in High Energy Physics experiments at the European Organization for Nuclear Research: ATLAS, CMS and ALICE, where hundreds of square meters of both trigger and timing RPCs have been…
Resistive Plate Chambers (RPCs) are essential active media of large-scale experiments as part of the muon systems and (semi-)digital hadron calorimeters. Among the several outstanding issues associated with the RPCs, the loss of efficiency…
Resistive Plate Chamber (RPC) is a well-known gaseous detector in the field of High Energy Physics (HEP) experiments for its good tracking capability, high efficiency, good time resolution, and low cost of fabrication. The main issue in RPC…
The Resistive Plate Chamber (RPC) is widely used in experiments of high energy physics as trigger detector as its good time resolution and high efficiency. In the traditional layout of RPC, the graphite layers are indispensable parts. The…
The Multigap Resistive Plate Chambers (MRPCs) are gas ionization detectors with multiple gas sub-gaps made of resistive electrodes. The high voltage (HV) is applied on the outer surfaces of outermost resistive plates only, while the…
We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with…
We report on the behaviour of Resistive Plate Chambers (RPC) developed for muon detection in ultra-high energy cosmic ray (UHECR) experiments. The RPCs were developed for the MARTA project and were tested on field conditions. These RPCs…