Related papers: First experimental test of a coded-mask gamma came…
Imaging of nuclear gamma-ray lines in the 1-10 MeV range is far from being established in both medical and physical applications. In proton therapy, 4.4 MeV gamma rays are emitted from the excited nucleus of either 12^C^* or 11^B^* and are…
Purpose: To demonstrate a proton imaging system based on well-established fast scintillator technology to achieve high performance with low cost and complexity, with the potential of a straightforward translation into clinical use. Methods:…
We are currently conceiving, through (MC) simulation, a multi-channel gamma detector array (TIARA for Time-of-flight Imaging ARrAy) for the online monitoring of protontherapy treatments. By measuring the Time-Of-Flight (TOF) between a beam…
Particle therapy is an established method to treat deep-seated tumours using accelerator-produced ion beams. For treatment planning, the precise knowledge of the relative stopping power (RSP) within the patient is vital. Conversion errors…
Proton therapy is nowadays becoming a wide spread clinical practice in cancer therapy and sophisticated treatment planning systems are routinely used to exploit at best the ballistic properties of charged particles. The information on the…
Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stopping power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stopping power in tissue…
The accuracy of hadrontherapy treatment is currently limited by ion-range uncertainties. In order to fully exploit the potential of this technique, we propose the development of a novel system for online control of particle therapy, based…
Prompt Gamma Timing (PGT) is a promising technique for in vivo range verification in particle therapy, exploiting the time-of-flight between primary particles and prompt gamma rays emitted by nuclear interactions. PGT distribution is highly…
Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become…
Physical and biological range uncertainties limit the clinical potential of Proton Beam Therapy (PBT). In this proceedings, we report on two research projects, which we are conducting in parallel and which both tackle the problem of range…
The advanced imaging and delivery techniques in proton therapy allow conformal high-dose irradiation of the target volume with high accuracy using pencil beam scanning or beam shaping apertures. These irradiation methods increasingly…
Objective: To develop and validate an independent Monet Carlo dose calculation engine to support for software verification of treatment planning systems and quality assurance workflow. Method: GATE Monte Carlo toolkit was employed to…
In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the…
In this work, we report on the advantageous aspects of the i-TED Compton imager for proton-range monitoring, based on the results of the first Monte Carlo study of its applicability to this field. i-TED is an array of Compton cameras, that…
Radiotherapy is one of the main methods in the successful treatment of cancer. The tumor is irradiated with photons or charged particles (e.g. protons), and in the case of massive charged particles, the treatment results in less unnecessary…
In this work, we proposed virtual imaging simulators as an alternative approach to experimental validation of beam range uncertainty in complex patient geometry using a computational model of a human head and a photon-counting CT scanner.…
We are exploring low-dose proton radiography and computed tomography (pCT) as techniques to improve the accuracy of proton treatment planning and to provide artifact-free images for verification and adaptive therapy at the time of…
Proton Computed Tomography (CT) is a prototype imaging modality for the reconstruction of the Relative Stopping Power of a patient, for more accurate calculations of the dose distributions in proton therapy dose planning. The measurements…
Proton Computed Tomography (pCT) provides a promising solution to enhance the accuracy of Relative Stopping Power (RSP) required for proton therapy planning. This research introduces a novel high-granularity pCT architecture that…
Uncertainties in the proton range in tissue during proton therapy limit the precision in treatment delivery. These uncertainties result in expanded treatment margins, thereby increasing radiation dose to healthy tissue. Real-time range…