The single-scatter approximation is fundamental in many tomographic imaging problems including x-ray scatter imaging and optical scatter imaging for certain media. In all cases, noisy measurements are affected by both local scatter events…
Due to the energy-dependent nature of the attenuation coefficient and the polychromaticity of the X-ray source, beam hardening effect occurs when X-ray photons penetrate through an object, causing a nonlinear projection data. When a linear…
Spontaneous photon scattering by an atomic qubit is a notable example of environment-induced error and is a fundamental limit to the fidelity of quantum operations. In the scattering process the qubit loses its distinctive and coherent…
In this study, we developed a new proton detector system called CATCH, which was designed for a scattering experiment involving a $\Sigma$ hyperon and a proton (J-PARC E40). CATCH is a cylindrical detector system covering an inner target…
Accurate attenuation and scatter corrections are crucial in positron emission tomography (PET) imaging for accurate visual interpretation and quantitative analysis. Traditional methods relying on computed tomography (CT) or magnetic…
The presence of a scattering medium in the imaging path between an object and an observer is known to severely limit the visual acuity of the imaging system. We present an approach to circumvent the deleterious effects of scattering, by…
Attenuation and scatter correction (AC) is crucial for quantitative Positron Emission Tomography (PET) imaging. Recently, direct application of AC in the image domain using deep learning approaches has been proposed for the hybrid PET/MR…
Electron Multiplying CCDs (EMCCDs) are used much less often than they might be because of the challenges they offer camera designers more comfortable with the design of slow-scan detector systems. However they offer an entirely new range of…
The new generation of multi-PetaWatt laser facilities will allow tests of Strong Field QED, as well as provide an opportunity for novel photon and lepton sources. The first experiments are planned to study the (nearly) head-on scattering of…
Computer-Assisted Interventions enable clinicians to perform precise, minimally invasive procedures, often relying on advanced imaging methods. Cone-beam computed tomography (CBCT) can be used to facilitate computer-assisted interventions,…
Light scattering in disordered media has been studied extensively due to its prevalence in natural and artificial systems [1]. In the field of photonics most of the research has focused on understanding and mitigating the effects of…
Modeling of the collimator-detector response (CDR) in SPECT reconstruction enables improved resolution and accuracy, and is thus important for quantitative imaging applications such as dosimetry. The implementation of CDR modeling, however,…
In dental cone-beam computed tomography (CBCT), compact and cost-effective system designs often use small detectors, resulting in a truncated field of view (FOV) that does not fully encompass the patient's head. In iterative reconstruction…
We present MInDI-3D (Medical Inversion by Direct Iteration in 3D), the first 3D conditional diffusion-based model for real-world sparse-view Cone Beam Computed Tomography (CBCT) artefact removal, aiming to reduce imaging radiation exposure.…
This paper presents an investigation of organic LED extraction efficiency enhancement using a low refractive index scattering layer. A scattering model is developed based on rigorous electromagnetic modelling techniques. The model accounts…
Four-dimensional Cone Beam Computed Tomography (4D-CBCT) has been developed to provide respiratory phase resolved volumetric imaging in image guided radiation therapy (IGRT). Inadequate number of projections in each phase bin results in low…
Common methods to achieve photon number resolution rely on fast on-off single-photon detectors in conjunction with temporal or spatial mode multiplexing. Yet, these methods suffer from an inherent trade-off between the efficiency of photon…
A Compton camera is the most promising approach for gamma-ray detection in the energy region from several hundred keV to MeV, especially for application in high energy astrophysics. In order to obtain good angular resolution, semiconductor…
Improving the image contrast of objects immersed in weakly scattering media can be achieved using various strategies. One common approach is to reject events associated with scattered photons in favor of the detection of ballistic photons.…
Photon-counting computed tomography has demonstrated significant advancements in recent years; however, micro photon-counting CT (Micro-PCCT) systems are still limited by pixel-wise detector response nonuniformity, which degrades…