Related papers: Optimizing Neon-based Gas Mixtures for Two-stage A…
The present work involves the comparison of various bulk Micromegas detectors having different design parameters. Six detectors with amplification gaps of $64,~128,~192,~220 ~\mu\mathrm{m}$ and mesh hole pitch of $63,~78 ~\mu\mathrm{m}$…
Micro-pattern gas detectors (MPGDs) are widely utilized in physics experiments owing to their excellent spatial resolution and high-rate capabilities. Within the PandaX-III experiment, which aims to investigate neutrinoless double beta…
We measured the properties of a novel combination of two Gas Electron Multipliers with a Micromegas for use as amplification devices in high-rate gaseous time projection chambers. The goal of this design is to minimize the buildup of space…
The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four representative pads. We demonstrate that…
The PICOSEC Micromegas detector is a Micro-Pattern Gaseous Detector concept developed to achieve tens of picosecond timing resolution for charged particle detection by combining a Cherenkov radiator with a two-stage Micromegas amplification…
The bulk Micromegas detector is considered to be a promising candidate for building TPCs for several future experiments including the projected linear collider. The standard bulk with a spacing of 128 micron has already established itself…
We present a comprehensive characterization of resistive PICOSEC Micromegas detector prototypes, tested under identical conditions, constant drift gap, field configurations, and photocathode at the CERN SPS H4 beam line. This work provides…
The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov…
The experimental requirements in near future accelerators (e.g. High Luminosity-LHC) has stimulated intense interest in development of detectors with high precision timing capabilities. With this as a goal, a new detection concept called…
Timing information in current and future accelerator facilities is important for resolving objects (particle tracks, showers, etc.) in extreme large particles multiplicities on the detection systems. The PICOSEC Micromegas detector has…
A recent Micromegas manufacturing technique, so called Microbulk, has been developed, improving the uniformity and stability of this kind of detectors. Excellent energy resolutions have been obtained, reaching values as low as 11% FWHM at…
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel non-resistive PICOSEC MM prototype with 10x10 cm^2 active…
The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof of concept single-channel small area prototype was able to…
Large area Gas Electron Multiplier (GEM) detectors have been the preferred choice for tracking devices in major nuclear and particle physics experiments. Uniformity over surface of the detector in terms of gain, energy resolution and…
Micromegas detector is considered to be a promising candidate for a large variety of high-rate experiments. Micromegas of various geometries have already been established as appropriate for these experiments for their performances in terms…
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and…
We report on a systematic characterization of microbulk Micromegas readouts in high-pressure Ar+1%iC4H10 and Ne+2%iC4H10 mixtures. Experimental data on gain, electron transmission and energy resolution are presented for a wide range of…
To meet the need for a high counting rate and high time resolution in future high-energy physics experiments, a prototype of a gas photodetector with an RPC structure was developed. Garfield++ simulated the detector's performance, and the…
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector conceprt was successfully demonstrated through a…
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| \eta |<2.4$ endcap region. With a sufficiently fine…