English
Related papers

Related papers: Performance Calculation of Pulse Shape Discriminat…

200 papers

Discrimination of the detection of fast neutrons and gamma rays in a liquid scintillator detector has been investigated using digital pulse-processing techniques. An experimental setup with a 252Cf source, a BC-501 liquid scintillator…

Nuclear Experiment · Physics 2008-12-08 P. -A. Söderström , J. Nyberg , R. Wolters

Traditionally, neutron-$\gamma$ discrimination in organic scintillators relies on techniques such as time-of-flight (ToF) selection and pulse-shape discrimination (PSD). However, particle identification through graphical cuts remains…

We report on the characterization of two inverted coaxial Ge detectors in the context of being employed in future $^{76}$Ge neutrinoless double beta ($0\nu\beta\beta$) decay experiments. It is an advantage that such detectors can be…

Instrumentation and Detectors · Physics 2018-04-04 A. Domula , M. Hult , Y. Kermaidic , G. Marissens , B. Schwingenheuer , T. Wester , K. Zuber

We have measured the time dependence of scintillation light from electronic and nuclear recoils in liquid neon, finding a slow time constant of 15.4+-0.2 us. Pulse shape discrimination is investigated as a means of identifying event type in…

Astrophysics · Physics 2008-11-26 J. A. Nikkel , R. Hasty , W. H. Lippincott , D. N. McKinsey

Using a single-phase liquid argon detector with a signal yield of 4.85 photoelectrons per keV of electronic-equivalent recoil energy (keVee), we measure the scintillation time dependence of both electronic and nuclear recoils in liquid…

Nuclear Experiment · Physics 2014-11-18 W. H. Lippincott , K. J. Coakley , D. Gastler , A. Hime , E. Kearns , D. N. McKinsey , J. A. Nikkel , L. C. Stonehill

The method of pulse-shape analysis (PSA) for particle identification (PID) was applied to a double-sided silicon strip detector (DSSD) with a strip pitch of 300 \{mu}m. We present the results of test measurements with particles from the…

Nuclear Experiment · Physics 2011-02-02 M. von Schmid , P. Egelhof , V. Eremin , R. Gernhäuser , T. Kröll , M. Mutterer , N. Pietralla , B. Streicher , M. Weber

We present a characterization of a small (9-liter) and mobile 0.1% 6Li-doped pulse-shape-sensitive plastic scintillator antineutrino detector called SANDD (Segmented AntiNeutrino Directional Detector), constructed for the purpose of…

Instrumentation and Detectors · Physics 2021-06-02 F. Sutanto , T. M. Classen , S. A. Dazeley , M. J. Duvall , I. Jovanovic , V. A. Li , A. N. Mabe , E. T. E. Reedy , T. Wu

We report on the response of a high light-output NaI(Tl) crystal to nuclear recoils induced by neutrons from an Am-Be source and compare the results with the response to electron recoils produced by Compton scattered 662 keV $\gamma$-rays…

The publicly accessible dataset includes neutron and gamma-ray pulse signals for conducting pulse shape discrimination experiments. Several traditional and recently proposed pulse shape discrimination algorithms are utilized to evaluate the…

Signal Processing · Electrical Eng. & Systems 2024-04-09 Kaimin Wang , Haoran Liu , Peng Li , Mingzhe Liu , Zhuo Zuo

Organic scintillators using a solid polyurethane (PU) matrix have been introduced to combine the robustness of a construction material with scintillating properties that allow gamma rays and fast neutrons to be detected efficiently and at…

Instrumentation and Detectors · Physics 2026-01-27 Olga Maiatska , Torsten Dünnebacke , Martin Kreuels , Guntram Pausch , Falko Scherwinski , Jürgen R. Stein

In recent years, particle discrimination methods based on digital waveform analysis techniques for neutron-transmutation-doped silicon (nTD-Si) detectors have become widely used for the identification of low-energy charged particles.…

Superheated drop detector (SDD) consisting of drops of superheated liquid of halocarbon is irradiated to neutrons and gamma-rays from 252Cf fission neutron source and 137Cs gamma source separately. The analysis of pulse height of the…

Instrumentation and Detectors · Physics 2014-11-21 Mala Das , S Seth , S Saha , S Bhattacharya , P Bhattacharjee

We demonstrate that fitted values of stellar radius obtained by fitting theoretical light curves to observations of millisecond period X-ray pulsars can significantly depend on the method used to calculate the light curves. The worst-case…

Astrophysics · Physics 2014-10-13 Coire Cadeau , Denis A. Leahy , Sharon M. Morsink

Pulse shape discrimination with pure CsI scintillators is investigated as a method for separating energy deposits by energetic neutrons and photons at particle physics experiments. Using neutron data collected near the European XFEL XS1…

Instrumentation and Detectors · Physics 2022-07-11 S. Longo , M. Khan , S. Dharani , B. von Krosigk , T. Ferber

A successfull application of Geiger-mode multipixel avalanche diodes (GMAPDs) for pulse-shape discrimination in alpha-beta spectrometry using organic liquid scintillator is described in this paper. Efficient discrimination of alpha and beta…

Instrumentation and Detectors · Physics 2015-05-28 I. Kreslo , I. Badhrees , S. Delaquis , A. Ereditato , S. Janos , M. Messina , U. Moser , B. Rossi , M. Zeller

In this paper we report results from a neutron irradiation campaign of Ultra-Fast Silicon Detectors (UFSD) with fluences of 1e14, 3e14, 6e14, 1e15, 3e15, 6e15 n/cm2. The UFSD used in this study are circular 50 micro-meter thick Low-Gain…

We report on the results of the positional-dependent pulse shape discrimination (PSD) parameter observed within a monolithic CLLB scintillation crystal. CLLB, a relatively novel inorganic scintillation crystal, is capable of PSD between…

Instrumentation and Detectors · Physics 2020-12-16 Richard S. Woolf , Bernard F. Phlips , Anthony L. Hutcheson , Andrew D. Maris , Eric A. Wulf

We constructed a neutron calibration facility based on a 300-mCi Am-Be source in conjunction with a search for weakly interacting massive particle candidates for dark matter. The facility is used to study the response of CsI(Tl) crystals to…

Liquid-argon scintillation detectors are used in fundamental physics experiments and are being considered for security applications. Previous studies have suggested that the addition of small amounts of xenon dopant improves performance in…

Instrumentation and Detectors · Physics 2014-06-23 Christopher G. Wahl , Ethan P. Bernard , W. Hugh Lippincott , James A. Nikkel , Yunchang Shin , Daniel N. McKinsey

The use of Time-over-Threshold (TOT) for the discrimination between fast neutrons and gamma-rays is advantageous when large number of detection channels are required due to the simplicity of its implementation. However, the results obtained…

Instrumentation and Detectors · Physics 2022-06-01 A. Roy , D. Vartsky , I. Mor , E. O. Cohen , Y. Yehuda-Zada , A. Beck , L. Arazi