Related papers: Performance Calculation of Pulse Shape Discriminat…
A monitoring system for fast neutrons is planned in the COSINE experiment, a dark matter experiment with NaI crystals. We pursued several R&D approaches for a neutron detector using a liquid scintillator (LS). A pulse shape discrimination…
The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is…
High-purity germanium detectors are widely used in rare-event searches due to their excellent energy resolution and extremely high intrinsic (radio)purity. In experiments searching for neutrinoless double beta decay in $^{76}$Ge such as…
The continued advancements of Silicon Photomultipliers (SiPMs) have made them viable photosensors for low recoil energy Pulse Shape Discrimination (PSD) between fast neutron and gamma interactions when coupled to an appropriate…
A series of test experiments on three different Si-based neutron detectors, namely a 1-d 128 channel, 0.5 mm space resolution Si microstrip sensor coupled to natural Gd converter, a medium size ? 1 cm2 PIN diode coupled to nGd2O3 or…
This work describes a class of liquid scintillators that contain mostly water (>50 wt. % of the entire composition) and can discriminate between interactions induced by neutrons and gamma rays. By balancing the interface interactions…
We present a detailed characterization of the thermal neutron sensitive transparent glass scintillator SG101, benchmarked against the conventional LiF ZnS(Ag)based scintillator EJ426. The detection efficiency, energy resolution, and pulse…
The energy and electric field dependence of pulse shape discrimination in liquid xenon have been measured in a 10 gm two-phase xenon time projection chamber. We have demonstrated the use of the pulse shape and charge-to-light ratio…
(Gd,La)$_2$Si$_2$O$_7$:Ce (La-GPS:Ce) is a new scintillator material with high light output, high energy resolution, and fast decay time. Moreover, the scintillator has a good light output even at high temperature (up to 150$^\circ$C) and…
The LaBr3:Ce scintillator has been widely studied for nuclear spectroscopy because of its optimal energy resolution (<3%@ 662 keV) and time resolution (~300 ps). Despite these promising properties, the intrinsic radiation background of…
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination…
In order to suppress the background in rare event detection experiments such as 0{\nu}\b{eta}\b{eta}, this paper developed a set of single/multi-site event pulse shape discrimination methods suitable for strip multi-electrode high-purity…
In this study, we evaluate and compare the pulse shape discrimination (PSD) performance of multipixel photon counters (MPPCs, also known as silicon photomultiphers - SiPMs) with that of a typical photomultiplier tube (PMT) when testing…
Detailed characterization of the newly available plastic scintillator (EJ-299-33A) having the pulse shape discrimination (PSD) property has been carried out in case of a large-sized detector (5 in.$\times$5 in.). The pulse height response…
A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with EJ-301 liquid scintillation detector. The module was operated by means of running programs developed in LabVIEW with the…
With the development of high-speed readout electronics, the digital pulse shape discrimination (PSD) methods have attracted the attention of more researchers, especially in the field of high energy physics and neutron detection. How to…
A brief outline of Dark Matter detection experiments using liquid argon technology is presented. The Pulse Shape background discrimination method (PSD) is described and the example of its use in 2.3 l R&D detector is given. Methods of…
In this contribution we report on further investigations of the recently-evaluated Constant-Fraction Time-over-Threshold (CF-ToT) method for neutron/gamma-ray pulse shape discrimination (PSD). The superiority of the CF-ToT PSD method over…
The GERDA experiment searches for the neutrinoless double beta decay of Ge-76 using high-purity germanium detectors enriched in Ge-76. The analysis of the signal time structure provides a powerful tool to identify neutrinoless double beta…
In beam test experiments have been carried out for particle identification using digital pulse shape analysis in a 500~$\mu$m thick Neutron Transmutation Doped (nTD) silicon detector with an indigenously developed FPGA based 12 bit…