English
Related papers

Related papers: Low Energy Backgrounds and Excess Noise in a Two-C…

200 papers

Solid state phonon detectors used in the search for dark matter and coherent neutrino nucleus interactions (CE$\nu$NS) require excellent energy resolution (eV-scale or below) and low backgrounds. An unknown source of phonon bursts, the low…

Experimental searches for axions or dark photons that couple to the standard model photon require photosensors with low noise, broadband sensitivity, and near zero backgrounds. Here, we introduce an experimental architecture, in which a…

Instrumentation and Detectors · Physics 2025-05-30 Roger K. Romani , Yen-Yung Chang , Rupak Mahapatra , Mark Platt , Maggie Reed , Ivar Rydstrom , Bernard Sadoulet , Bruno Serfass , Matt Pyle

Solid-state phonon and charge detectors probe the scattering of weakly interacting particles, such as dark matter and neutrinos, through their low recoil thresholds. Recent advancements have pushed sensitivity to eV-scale energy…

Transition edge sensors (TESs) are superconducting energy-resolving microcalorimeters that have demonstrated low background rates as well as quantum efficiencies close to unity for photons at optical and near-infrared wavelengths. This…

Low threshold cryogenic calorimeters are a key technology for the advancement of rare-event searches. However, since a few years their sensitivity reach is challenged by the presence of a rising spectrum at low energies named low-energy…

Instrumentation and Detectors · Physics 2026-05-29 Vanessa Zema , Pasquale Pavone

A previously unexplained background called the Low Energy Excess (LEE) has negatively impacted the reach of a variety of low threshold calorimeters including light dark matter direct detection and coherent elastic neutrino-nucleus…

Instrumentation and Detectors · Physics 2024-09-27 Roger K. Romani

In recent years, theoretical and experimental interest in dark matter (DM) candidates have shifted focus from primarily Weakly-Interacting Massive Particles (WIMPs) to an entire suite of candidates with masses from the zeV-scale to the…

High Energy Physics - Experiment · Physics 2023-01-23 Samuel L. Watkins

We have combined two low-threshold detector technologies to develop a large-mass, low-threshold detector system that simultaneously measures the athermal phonons in a sapphire detector while an adjacent silicon high-voltage detector detects…

Instrumentation and Detectors · Physics 2023-06-14 M. Chaudhuri , G. Agnolet , V. Iyer , V. K. S. Kashyap , M. Lee , R. Mahapatra , S. Maludze , N. Mirabolfathi , B. Mohanty , M. Platt , A. Upadhyay , S. Sahoo , S. Verma

Superconducting transition-edge sensors (TESs) are a type of quantum sensor known for its high single-photon detection efficiency and low background. This makes them ideal for particle physics experiments searching for rare events. In this…

The next generation of ultra-low-noise cryogenic detectors for space science applications require continued exploration of materials characteristics at low temperatures. The low noise and good energy sensitivity of current Transition Edge…

Mesoscale and Nanoscale Physics · Physics 2011-02-01 D. J. Goldie , D. M. Glowacka , K. Rostem† , S. Withington

The phonon-mediated hybrid detector is made out of a monolithic silicon crystal characterized by two interconnected regions linked through a narrow neck. Operating solely on phonon signal measurements, the hybrid design facilitates the…

Transition-edge sensors (TES) are photon-number resolving calorimetric spectrometers with near unit efficiency. Their recovery time, which is on the order of microseconds, limits the number resolving ability and timing accuracy in high…

Instrumentation and Detectors · Physics 2018-12-21 Jianwei Lee , Lijiong Shen , Alessandro Cerè , Thomas Gerrits , Adriana E. Lita , Sae Woo Nam , Christian Kurtsiefer

We have fabricated Transition Edge Sensors (TESs) whose thermal characteristics are completely characterised by few-mode ballistic phonon exchange with the heat bath. These TESs have extremely small amorphous SiNx support legs: 0.2 um…

Mesoscale and Nanoscale Physics · Physics 2015-06-18 Djelal Osman , Stafford Withington , David J Goldie , Dorota M Glowacka

Recent results from the SENSEI experiment show that a cut on event clustering can reduce low-energy excesses in their eV-sensitive calorimeter. This hints at the role of surrounding uninstrumented surfaces in producing backgrounds. Charged…

Instrumentation and Methods for Astrophysics · Physics 2020-10-22 Alan E. Robinson

Transition-Edge Sensors (TESs) are two-dimensional superconducting films used to detect energy or power. TESs are voltage biased in the resistive transition where the film resistance is both finite and a strong function of temperature.…

We describe the construction and operation of a two-channel noise detection system for measuring power and cross spectral densities of current fluctuations near 2 MHz in electronic devices at low temperatures. The system employs cryogenic…

Mesoscale and Nanoscale Physics · Physics 2009-11-11 L. DiCarlo , Y. Zhang , D. T. McClure , C. M. Marcus , L. N. Pfeiffer , K. W. West
‹ Prev 1 2 3 10 Next ›