Ultra-high dose rate electron sources require dose rate independent dosimeters and a calibrated dose control system for accurate delivery. In this study, we developed a single-pulse dose monitoring and a real-time dose-based control system…
The Centers for Medicare & Medicaid Services (CMS) has introduced CMS1074v2, a quality measure for computed tomography (CT) that assesses radiation dose and image quality across 18 CT exam categories. This measure mandates the calculation…
Intensity-modulated proton therapy (IMPT) employs proton radiation rather than conventional X-rays to treat cancerous tumors. This approach offers significant advantages by minimizing the radiation exposure of surrounding healthy tissue,…
The LaBr3:Ce scintillator has been widely studied for nuclear spectroscopy because of its optimal energy resolution (<3%@ 662 keV) and time resolution (~300 ps). Despite these promising properties, the intrinsic radiation background of…
The abundance and fractionation of the stable strontium (Sr) isotope system are being increasingly utilized to move forward our understanding in geological and cosmological processes. Two analytical techniques are commonly used to measure…
Silicon carbide (SiC) planar PiN diodes from two different manufacturers were irradiated with 252.7 MeV protons from a medical synchrotron. Over the course of two 8h irradiation shifts, the samples were exposed to increasing fluences…
Exact calculations of the radiative corrections to the single spin asymmetry in the exclusive pion electroproduction below $\Delta(1232)$ resonance are performed by employing the EXCLURAD code. The analysis of the dependence of the obtained…
The aim of this study was to optimize the design of a monolithic LGSO scintillation crystal and micro parallel-hole collimator for the development of a small-animal single photon emission computed tomography (SPECT) system with compact…
For dose calculations in ion beam therapy, it is vital to accurately determine the relative stopping power (RSP) distribution within the treated volume. Currently, RSP values are extrapolated from Hounsfield units (HU), measured with x-ray…
The dual-radiator RICH (dRICH) detector of the ePIC experiment will employ over 300000 SiPM pixels as photosensors, organized into more than 1000 Photon Detection Units. Each PDU is a compact module, approximately 5x5x12 cm^3 in size,…
The properties of large volume cylindrical 3.5 x 8 inches (89 mm x 203 mm) LaBr3:Ce scintillation detectors coupled to the Hamamatsu R10233-100SEL photo-multiplier tube were investigated. These crystals are among the largest ones ever…
When solving partial differential equations on scattered nodes using the Radial Basis Function-generated Finite Difference (RBF-FD) method, one of the parameters that must be chosen is the stencil size. Focusing on Polyharmonic Spline RBFs…
X-ray diffraction (XRD) peak broadening analysis remains a cornerstone for quantifying crystallite size and lattice microstrain in materials. Among various approaches, the Size Strain Plot (SSP) method is widely employed for its conceptual…
Phosphorescent metal complexes have been under intense investigations as emissive dopants for energy efficient organic light emitting diodes (OLEDs). Among them, cyclometalated Pt(II) complexes are widespread triplet emitters with…
A new high-granular compact time-of-flight neutron detector for the identification and energy measurement of neutrons produced in nucleus-nucleus interactions at the BM@N experiment, Dubna, Russia, at energies up to 4 AGeV is under…
In this study, we present a complex investigation for miniaturizing of perovskite photodiodes (PPDs) in various geometries with use of ultraviolet laser scribing (UV-LS). Employing a 355 nm (3.5 eV) pulsed laser at 30 kHz, we successfully…
Despite major advances in oncology, many chemotherapeutic agents still cause severe side effects that reduce quality of life, motivating new approaches for early detection and targeted elimination of cancer cells. Luminescent transition…
Purpose: Prior AI-based dose prediction studies in photon and proton therapy often neglect underlying physics, limiting their generalizability to handle outlier clinical cases, especially for pencil beam scanning proton therapy (PBSPT). Our…
Small-pitch 3D silicon pixel detectors have been investigated as radiation-hard candidates for the innermost layers of the HL-LHC pixel detector upgrades. Prototype 3D sensors with pixel sizes of 50$\times$50 and 25$\times$100 $\mu$m$^{2}$…
A barrel-shaped plastic scintillation counter with Multi-Pixel Photon Counter (MPPC) readout has been developed and operated in the first WASA-FRS experimental campaign at GSI. The detector was used to measure charged particles emitted from…