Related papers: Compact beam position monitor using a segmented to…
A compact beam-profile monitor was constructed using a linear contact image sensor attached to a plastic scintillator and tested using a 230 MeV proton beam. The results indicate that the beam distribution can be obtained in real-time, and…
The nano-meter beam size in future linear colliders requires very high resolution beam position monitor since higher resolution allows more accurate position measurement in the interaction point. We developed and tested a low-Q C-band beam…
A high-accuracy calibration of inductive coil sensors based on Printed Circuit Board (PCB), commonly used in rotating coil field measurements of particle accelerator magnets, is presented. The amplitude and phase of signals with and without…
Beam position monitors (BPMs) are indispensable components of modern particle accelerators, providing real-time diagnostics to ensure precise beam control, stability, and quality. As accelerators such as the International Linear Collider…
We present the design of a Faraday cup-like charged particle detector in a four quadrant configuration aimed at facilitating the alignment of low-intensity beams of exotic particles. The device is capable of assessing the current on the…
A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current…
A system for bunch-by-bunch detection of transverse proton and antiproton coherent oscillations in the Fermilab Tevatron collider is described. It is based on the signal from a single beam-position monitor located in a region of the ring…
Detection of moving charge in free space is presented in the framework of single electron CMOS devices. It opens the perspective for construction of new type detectors for beam diagnostic in accelerators or for the detection of solar wind.…
Various beam-based methods are widely used for machine study and accurate tuning. Beam closed orbit (CO) responses are routinely used worldwide for magnetic elements alignment and lattice correction. The paper presents the beam-based field…
Atomic spin sensors offer precision measurements using compact, microfabricated packages, placing them in a competitive position for both market and research applications. Performance of these sensors such as dynamic range may be enhanced…
We propose a new scintillator-based tracker concept based on a monolithic plastic scintillator plate with embedded scatterers and wavelength-shifting fiber readout. The embedded scatterers localize scintillation light so that channels…
A prototype particle tracking telescope has been constructed using Timepix and Medipix ASIC hybrid pixel assemblies as the six sensing planes. Each telescope plane consisted of one 1.4 cm2 assembly, providing a 256x256 array of 55 micron…
A beam profile monitor utilizing visible synchrotron radiation (SR) from a bending magnet has been designed and installed in Cornell Electron-Positron Storage Ring (CESR). The monitor employs a double-slit interferometer to measure both the…
A simple, analytically correct algorithm is developed for calculating pencil beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The…
The efficiency of beam injection in circular accelerators can be impacted by unknown aperture limitations in the vacuum chamber. These limitations can be detected by introducing localized distortions to the closed orbit of the circulating…
A cylindrical GEM tracker is under construction in order to replace and improve the inner tracking system of the BESIII experiment. Tests with planar chamber prototypes were carried out on the H4 beam line of SPS (CERN) with muons of 150…
The precision of compact inertial sensing schemes using trapped- and guided-atom interferometers has been limited by uncontrolled phase errors caused by trapping potentials and interactions. Here, we propose an acoustic interferometer that…
A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E$\times$B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in…
A beam-energy-spread monitor is under development in order to control and stabilize the energy spread of high-current single-bunch electron beams for producing a sufficient number of positrons. The author has proposed a new monitor using…
In a new toroidal laboratory plasma device including a poloidal magnetic field created by an internal circular conductor, the confinement efficiency of the magnetized plasma and the turbulence level are studied in different situations. The…