Related papers: A procedure to characterize the performance of Ene…
AXEL is a high pressure xenon gas TPC detector being developed for neutrinoless double-beta decay search. We use the proportional scintillation mode with a new electroluminescence light detection system to achieve high energy resolution in…
The GALAXIES beamline at the SOLEIL synchrotron is dedicated to inelastic x-ray scattering (IXS) and photoelectron spectroscopy (HAXPES) in the 2.3-12 keV hard x-ray range. These two techniques offer powerful, complementary methods of…
Fine structure analysis of core electron excitation spectra is a cornerstone characterization technique across the physical sciences. Spectra are most commonly measured with synchrotron radiation and X-ray spot sizes on the {\mu}m to mm…
The European X-ray Free Electron Laser (EuXFEL) is a research facility providing spatially coherent X-ray flashes in the energy range from 0.25keV to 25keV of unprecedented brilliance and with unique time structure: X-ray pulses with a 4.5…
The development prospects have been considered of a scintillator-photodiode type detector with improved energy resolution attaining several per cent ($R=1-2%$). The main contributions to the scintielectron detector energy resolution have…
AXEL is a high-pressure xenon gas time projection chamber for neutrinoless double-beta decay (0n2b) search. The AXEL has a unique readout system called ELCC which has a cellular structure and photosensors to detect electroluminescence light…
The energy resolution of the EXO-200 detector is limited by electronics noise in the measurement of the scintillation response. Here we present a new technique to extract optimal scintillation energy measurements for signals split across…
The ANATOMIX beamline at Synchrotron SOLEIL, operational since 2018, is dedicated to hard X-ray full-field tomography techniques. Operating in a range of photon energies from approximately 5 to 50 keV, it offers both parallel-beam…
In recent years, deep learning systems have shown a concerning trend toward increased complexity and higher energy consumption. As researchers in this domain and organizers of one of the Detection and Classification of Acoustic Scenes and…
The hyperspectral X-ray imaging has been long sought in various fields from material analysis to medical diagnosis. Here we propose a new semiconductor detector structure to realize energy-resolved imaging at potentially low cost. The…
Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted…
We report on the production of an array of active edge silicon sensors as a prototype of a large array. Four Medipix3RX.1 chips were bump bonded to four single chip sized Advacam active edge n-on-n sensors. These detectors were then mounted…
A photon-counting silicon strip detector with two energy thresholds was investigated for spectral X-ray imaging in a mammography system. Preliminary studies already indicate clinical benefit of the detector, and the purpose of the present…
Synchrotron radiation facilities provide highly polarized X-ray beams across a wide energy range. However, the exact type and degree of polarization varies according to the beamline and experimental setup. To accurately determine the angle…
Future strategic X-ray satellite telescopes, such as the probe-class Advanced X-ray Imaging Satellite (AXIS), will require excellent soft energy response in their imaging detectors to enable maximum discovery potential. In order to…
This paper presents performance measurements of a new readout electronics system based on silicon photomultipliers for the PHENIX electromagnetic calorimeter. Installation of the lead-scintillator Shashlik style calorimeter into the…
We report a systematic determination of the responses of PandaX-II, a dual phase xenon time projection chamber detector, to low energy recoils. The electron recoil (ER) and nuclear recoil (NR) responses are calibrated, respectively, with…
The measurement of shifts in the energy of X-ray emission lines is important for understanding the electronic structure and physical properties of materials. In this study, we demonstrate a method using a synchrotron source to introduce…
The development prospects of a scintillator-photodiode type detector with an improved energy resolution attaining few per cent, R from 1 to 2%, are considered. The main resolution components have been analyzed theoretically, their…
A triple-GEM detector with two-dimensional readout is developed. The detector provides high position resolution for powder diffraction experiments at synchrotron radiation. Spatial resolution of the detector is measured in the lab using a…