English
Related papers

Related papers: Optically pumped vector magnetometer using a stron…

200 papers

We have designed and tested an atomic vectorial magnetometer based on the analysis of the coherent oscillatory transients in the transmission of resonant laser light through a Rb vapor cell. We show that the oscillation amplitudes at the…

Atomic Physics · Physics 2015-06-18 L. Lenci , A. Auyuanet , S. Barreiro , P. Valente , A. Lezama , H. Failache

We report what we believe is the first experimental limit placed on plant biomagnetism. Measurements with a sensitive atomic magnetometer were performed on the Titan arum (Amorphophallus titanum) inflorescence, known for its fast…

Measuring the field of visible light with high spatial resolution has been challenging, as many established methods only detect a focus-averaged signal. Here, we introduce a near-field method for optical field sampling that overcomes that…

The nitrogen-vacancy (NV) color center in diamond is an atom-like system in the solid-state which specific spin properties can be efficiently used as a sensitive magnetic sensor. An external magnetic field induces Zeeman shifts of the NV…

Mesoscale and Nanoscale Physics · Physics 2015-07-17 M. Chipaux , A. Tallaire , J. Achard , S. Pezzagna , J. Meijer , V. Jacques , J. -F. Roch , T. Debuisschert

We study the effect of optical polarization squeezing on the performance of a sensitive, quantum-noise-limited optically pumped magnetometer. We use Bell-Bloom (BB) optical pumping to excite a $^{87}$Rb vapor containing $8.2 \cdot 10^{12}…

Quantum Physics · Physics 2021-11-05 C. Troullinou , R. Jiménez-Martínez , J. Kong , V. G. Lucivero , M. W. Mitchell

We present an all-optical method to measure and compensate for residual magnetic fields present in a cloud of ultracold atoms trapped in an optical dipole trap. Our approach leverages the increased loss from the trapped atomic sample…

Atomic Physics · Physics 2024-04-18 Suthep Pomjaksilp , Sven Schmidt , Aaron Thielmann , Thomas Niederprüm , Herwig Ott

Atomic magnetometers based on Zeeman shift measurement have the potential for high sensitivity and long-term stability. Like other atomic sensors including atomic clocks and atom interferometers, the atomic magnetometer could in principle…

Quantum Physics · Physics 2025-02-17 Jinyang Li , Gour Pati , Renu Tripathi , Selim M Shahriar

We investigate the ground-state Hanle effect in alkali-metal vapor irradiating by a resonant elliptically polarized light wave. The magneto-optical resonances are observed as a change in the ellipticity parameter of the light wave…

Atomic Physics · Physics 2025-11-25 D. V. Brazhnikov , A. O. Makarov , K. S. Kozlova , A. N. Goncharov

Precision sensing, and in particular high precision magnetometry, is a central goal of research into quantum technologies. For magnetometers, often trade-offs exist between sensitivity, spatial resolution, and frequency range. The…

Quantum Physics · Physics 2016-06-22 I. Baumgart , J. -M. Cai , A. Retzker , M. B. Plenio , Ch. Wunderlich

A sensitive vector magnetometry with high spatial resolution is important for various practical applications, such as magnetocardiography, magnetoencephalography, explosive materials detection and many others. We propose a magnetometer…

Applied Physics · Physics 2021-07-07 D. O. Ignatyeva , G. A. Knyazev , A. N. Kalish , A. I. Chernov , V. I. Belotelov

We develop a weak measurement scheme for measuring orbital angular momentum (OAM) of light based on the global topology in wave function. We introduce the spin-orbit coupling to transform the measurement of OAM to the pre- and postselected…

Optics · Physics 2024-10-02 Junfan Zhu , An Wang , Yurong Liu , Fuhua Gao , Zhiyou Zhang

Atom interferometers deployed in space are excellent tools for high precision measurements, navigation, or Earth observation. In particular, differential interferometric setups feature common-mode noise suppression and enable reliable…

We use a magnetometer probe based on the Zeeman shift of the rubidium resonant optical transition to explore the atomic magnetic response for a wide range of field values. We record optical spectra for fields from few tesla up to 60 tesla,…

Atomic Physics · Physics 2017-11-22 D. Ciampini , R. Battesti , C. Rizzo , E. Arimondo

The problem of detection of magnetic fields using NV centers, that is, to check whether a weak magnetic field is present or not, can be tackled using quantum state discrimination theory. In this regard, we find the POVMs that maximize the…

Quantum Physics · Physics 2021-12-10 Ghazi Khan , Adam Zaman Chaudhry

Optical pumping of barium monofluoride (BaF) within a cryogenic neon matrix is demonstrated. Interestingly, with an applied magnetic field of 2~G, optical pumping is found to be considerably more efficient for a laser beam with…

In this article, operation of optical magnetometers detecting static (DC) and oscillating (AC) magnetic fields is studied and comparison of the devices is performed. To facilitate the comparison, the analysis is carried out in the same…

Atomic Physics · Physics 2019-04-02 Piotr Put , Kacper Popiołek , Szymon Pustelny

In a magnetic field detection system,to achieve high-sensitivity magnetic field measurement, it is necessary to use uniform magnetic field coils to provide a stable working environment, so the measurement of the magnetic field coilsconstant…

Atomic Physics · Physics 2024-02-08 Ni Zhao , Lulu Zhang , Yongbiao Yang , Junye Zhao , Jun He , Junmin Wang

Oblique plane microscopy (OPM) enables high speed, volumetric fluorescence imaging through a single-objective geometry. While these advantages have positioned OPM as a valuable tool to probe biological questions in animal models, its…

The performance of laser-based active sensing has been severely limited by two types of noise: electrical noise, stemming from elements; optical noise, laser jamming from an eavesdropper and background from environment. Conventional methods…

Magnetic fields play an important role in the evolution of molecular clouds and star formation. Using the Velocity Gradient Technique (VGT) model, we measured the magnetic field in Orion A using the 12CO, 13CO, and C18O (1-0) emission lines…

‹ Prev 1 8 9 10 Next ›