Objective: The aim of this study is to validate the effectiveness of an energy-modulated scatter correction method in suppressing scatter in photon-counting detector (PCD)-based cone beam CT (CBCT) imaging. Approach: The scatter correction…

Medical Physics · Physics 2024-12-18 Xin Zhang , Ting Su , Jiongtao Zhu , Hairong Zheng , Dong Liang , Yongshuai Ge

Background: Dual-energy (DE) imaging techniques in cone-beam computed tomography (CBCT) have potential clinical applications, including material quantification and improved tissue visualization. However, the performance of DE CBCT is…

Medical Physics · Physics 2023-06-26 Cem Altunbas

Purpose: Fast kV-switching (FKS) and dual-layer flat-panel detector (DL-FPD) technologies have been actively studied as promising dual-energy solutions for FPD-based cone-beam computed tomography (CBCT). However, CBCT spectral imaging is…

Medical Physics · Physics 2024-01-03 Hao Zhou , Li Zhang , Zhilei Wang , Hewei Gao

Objective: This study aims at investigating a novel super resolution CBCT imaging technique with the dual-layer flat panel detector (DL-FPD). Approach: In DL-FPD based CBCT imaging, the low-energy and high-energy projections acquired from…

Medical Physics · Physics 2023-06-29 Jiongtao Zhu , Ting Su , Xin Zhang , Han Cui , Yuhang Tan , Hairong Zheng , Dong Liang , Jinchuan Guo , Yongshuai Ge

Conventional cone-beam CT (CBCT) can be easily compromised by scatter and beam hardening artifacts, and the entanglement of scatter and spectral effects introduces additional complexity. In this work, we present the first attempt to develop…

Medical Physics · Physics 2025-01-07 Yifan Deng , Hao Zhou , Zhilei Wang , Adam S. Wang , Hewei Gao

Cone-beam CT (CBCT) is installed in the treatment room to facilitate online clinical applications, including image guidance in radiation and surgery. Half-fan and short-can are the commonly used modes in clinical applications to expand the…

Medical Physics · Physics 2022-05-24 Junbo Peng

As photon counting detectors are being explored for medical and industrial imaging applications, there is a critical need to understand spectral characteristics of scattered x-ray photons. Scattered radiation is detrimental to x-ray imaging…

Medical Physics · Physics 2022-12-14 Cale E. Lewis , Mini Das

Purpose: Scatter artifacts drastically degrade the image quality of cone-beam computed tomography (CBCT) scans. Although deep learning-based methods show promise in estimating scatter from CBCT measurements, their deployment in mobile CBCT…

Signal Processing · Electrical Eng. & Systems 2025-09-12 Harshit Agrawal , Ari Hietanen , Simo Särkkä

Poor tissue visualization and quantitative accuracy in CBCT is a major barrier in expanding the role of CBCT imaging from target localization to quantitative treatment monitoring and plan adaptations in radiation therapy sessions. To…

Medical Physics · Physics 2023-08-21 Farhang Bayat , Dan Ruan , Moyed Miften , Cem Altunbas

Cone-beam CT (CBCT) employs a flat-panel detector to achieve three-dimensional imaging with high spatial resolution. However, CBCT is susceptible to scatter during data acquisition, which introduces CT value bias and reduced tissue contrast…

Computer Vision and Pattern Recognition · Computer Science 2025-10-29 Xu Jiang , Huiying Pan , Ligen Shi , Jianing Sun , Wenfeng Xu , Xing Zhao

Scatter due to interaction of photons with the imaged object is a fundamental problem in X-ray Computed Tomography (CT). It manifests as various artifacts in the reconstruction, making its abatement or correction critical for image quality.…

Medical Physics · Physics 2024-01-30 Berk Iskender , Yoram Bresler

For medical cone-beam computed tomography (CBCT) imaging, the native receptor array of the flat-panel detector (FPD) is usually binned into a reduced matrix size. By doing so, the signal readout speed can be increased by over 4-9 times at…

Medical Physics · Physics 2022-10-18 Ting Su , Jiongtao Zhu , Xin Zhang , Dong Zeng , Yuhang Tan , Han Cui , Hairong Zheng , Jianhua Ma , Dong Liang , Yongshuai Ge

Recently, spectral CT has been drawing a lot of attention in a variety of clinical applications primarily due to its capability of providing quantitative information about material properties. The quantitative integrity of the reconstructed…

Medical Physics · Physics 2018-01-12 Shiyu Xu , Peter Prinsen , Jens Wiegert , Ravindra Manjeshwar

This paper provides a fast and patient-specific scatter artifact correction method for cone-beam computed tomography (CBCT) used in image-guided interventional procedures. Due to increased irradiated volume of interest in CBCT imaging,…

Medical Physics · Physics 2015-01-20 Wei Zhao , Stephen Brunner , Kai Niu , Sebastian Schafer , Kevin Royalty , Guang-Hong Chen

The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain…

Medical Physics · Physics 2016-04-27 Wei Zhao , Don Vernekohl , Jun Zhu , Luyao Wang , Lei Xing

Background: Dual-energy imaging on cone-beam CT (CBCT) scanners has great potential in different clinical applications, including image-guided surgery and adaptive proton therapy. However, the clinical practice of dual-energy CBCT (DE-CBCT)…

We propose a new modeling approach for scatter estimation and descattering in polyenergetic X-ray computed tomography (CT) based on fitting models to local neighborhoods of a training set. X-ray CT is widely used in medical and industrial…

Image and Video Processing · Electrical Eng. & Systems 2021-09-30 Michael T. McCann , Marc L. Klasky , Jennifer L. Schei , Saiprasad Ravishankar

Cone-beam computed tomography (CBCT) has been widely used in medical imaging and industrial nondestructive testing, but the presence of scattered radiation will cause significant reduction of image quality. In this article, a robust scatter…

Medical Physics · Physics 2016-08-03 Kuidong Huang , Zhe Xu , Dinghua Zhang , Hua Zhang , Wenlong Shi

X-ray energy spectrum plays an essential role in computed tomography (CT) imaging and related tasks. Due to the high photon flux of clinical CT scanners, most of spectrum estimation methods are indirect and usually suffered from various…

Medical Physics · Physics 2017-06-14 Wei Zhao , Lei Xing , Qiude Zhang , Qingguo Xie , Tianye Niu

Due to its wide field of view, cone-beam computed tomography (CBCT) is plagued by large amounts of scatter, where attenuated photons hit the detector, and corrupt the linear models used for reconstruction. Given that one can generate a good…

Medical Physics · Physics 2017-07-06 Jonathan Mason , Alessandro Perelli , William Nailon , Mike Davies