Related papers: CBCT scatter correction with dual-layer flat-panel…
Objective: To propose a CBCT dose optimization method using readily available measurement equipment in radiation oncology departments. Approach: A 0.6cc air kerma (Kair) calibrated Farmer chamber measured Kair at isocenter for five default…
In radiation therapy (RT), the reliance on pre-treatment computed tomography (CT) images encounter challenges due to anatomical changes, necessitating adaptive planning. Daily cone-beam CT (CBCT) imaging, pivotal for therapy adjustment,…
We discuss a new solution of the Kompaneets-equation for physical situations in which low frequency photons, forming relatively narrow spectral details, are Compton scattered in an isotropic, infinite medium with an intense ambient…
Deep learning-based reconstruction of positron emission tomography(PET) data has gained increasing attention in recent years. While these methods achieve fast reconstruction,concerns remain regarding quantitative accuracy and the presence…
Scattering imaging is often hindered by extremely low signal-to-noise ratios (SNRs) due to the prevalence of scattering noise. Light field imaging has been shown to be effective in suppressing noise and collect more ballistic photons as…
The scattering of light observed through the turbid underwater channel is often regarded as the leading challenge when designing underwater electro-optical imaging systems. There have been many approaches to address the effects of…
Non-invasive detection of objects embedded inside an optically scattering medium is essential for numerous applications in engineering and sciences. However, in most applications light at visible or near-infrared wavebands is scattered by…
Doing quantitative computed tomography (CT) using Bremsstrahlung sources requires an estimate of the spectrum emitted by the X-ray source. One method of beam hardening correction (BHC), as described by Lifton[1], first uses transmission…
Neutron spectrum and scattered neutrons caused distortions are major problems in fast neutron radiography and should be considered for improving the image quality. This paper puts emphasis on the removal of these image distortions and…
Spectral Domain Optical Coherence Tomography (SD-OCT) is a well-known imaging modality which allows for \textit{in-vivo} visualization of the morphology of different biological tissues at cellular level resolutions. The overall SD-OCT…
In materials science and particularly electron microscopy, Electron Back-scatter Diffraction (EBSD) is a common and powerful mapping technique for collecting local crystallographic data at the sub-micron scale. The quality of the…
Dual-energy CT (DECT) has been widely investigated to generate more informative and more accurate images in the past decades. For example, Dual-Energy Alternating Minimization (DEAM) algorithm achieves sub-percentage uncertainty in…
A bowtie is a filter used to shape an x-ray beam and equalize its flux reaching different detector channels. For development of spectral CT with energy-discriminative photon-counting (EDPC) detectors, here we propose and evaluate a dynamic…
Computed Tomography (CT) imaging is one of the most influential diagnostic methods. In clinical reconstruction, an effective energy is used instead of total X-ray spectrum. This approximation causes an accuracy decline. To increase the…
Scattering of light in complex media scrambles optical wavefronts and breaks the principles of conventional imaging methods. For decades, researchers have endeavored to conquer the problem by inventing approaches such as adaptive optics,…
In a preceding paper we introduced a formalism to study the scattering of low intensity fields from a system of multi-level emitters embedded in a $3$D dielectric medium. Here we show how this photon-scattering relation can be used to…
Background: Cone-beam computed tomography (CBCT) plays a crucial role in image-guided radiotherapy, but artifacts and noise make them unsuitable for accurate dose calculation. Artificial intelligence methods have shown promise in enhancing…
We developed a 2-mm-thick CdTe double-sided strip detector (CdTe-DSD) with a 250 um strip pitch, which has high spatial resolution with a uniform large imaging area of 10 cm$^2$ and high energy resolution with high detection efficiency in…
Contrast resolution beyond the limits of conventional cone-beam CT (CBCT) systems is essential to high-quality imaging of the brain. We present a deep learning reconstruction method (dubbed DL-Recon) that integrates physically principled…
Attenuation compensation (AC) is a pre-requisite for reliable quantification and beneficial for visual interpretation tasks in single-photon emission computed tomography (SPECT). Typical AC methods require the availability of an attenuation…