Photosensitive gaseous detectors with a simple photoelectron multiplication mechanism of resistive plate chambers (RPCs) are expected to have both a large photocoverage and an excellent time resolution and to be low-cost. To demonstrate the…

Instrumentation and Detectors · Physics 2023-05-24 K. Matsuoka , R. Okubo , Y. Adachi

A new particle detector with sub-nanosecond time resolution capable of working in high-rate environment (rate capability of the order of $MHz/ cm^2$) is under developmnet. Semiconductive electrodes with resistivity $\rho$ up to $10^8…

Instrumentation and Detectors · Physics 2020-01-29 A. Rocchi , R. Cardarelli , G. Aielli , E. Alunno Camelia , S. Bruno , A. Caltabiano , P. Camarri , A. Di Ciaccio , B. Liberti , L. Massa , L. Pizzimento

The Multigap Resistive Plate Chambers (MRPCs) are gas ionization detectors with multiple gas sub-gaps made of resistive electrodes. The high voltage (HV) is applied on the outer surfaces of outermost resistive plates only, while the…

Instrumentation and Detectors · Physics 2016-12-16 Moon Moon Devi , Naba K. Mondal , B. Satyanarayana , R. R. Shinde

The Multigap Resistive Plate Chamber (MRPC) is a gaseous detector; the performance depends very much on the gas mixture as well as the design. MRPCs are used as a timing device in several collider experiments and cosmic ray experiments…

Instrumentation and Detectors · Physics 2019-03-27 Yongwook Baek , Dowon Kim , M. C. S. Williams

The low cost and high resolution gas-based Multi-gap Resistive Plate Chamber (MRPC) opens a new possibility to find an efficient alternative detector for Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the…

Instrumentation and Detectors · Physics 2011-06-30 A. Banerjee , S. Chattopadhyay

The Multi-gap Resistive Plate Chamber (MRPC) is an advanced form of Resistive Plate Chamber (RPC) detector where the gas gap is divided into sub-gaps. MRPCs are known for their good time resolution and detection efficiency for charged…

Instrumentation and Detectors · Physics 2018-08-15 Rajesh Ganai , Mitali Mondal , Shaifali Mehta , Zubayer Ahammed , Subhasis Chattopadhyay

The low cost and high resolution Multi-gap Resistive Plate Chamber (MRPC) opens up a new possibility to find an efficient alternative detector for the Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the…

Instrumentation and Detectors · Physics 2015-06-22 A. Banerjee , A. Roy , S. Biswas , S. Chattopadhyay , G. Das , S. Pal

Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the…

Instrumentation and Detectors · Physics 2022-10-26 Jaydeep Datta , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar

There are several applications which require high position resolution UV imaging. For these applications we have developed and successfully tested a new version of a 2D UV single photon imaging detector based on a microgap RPC. The main…

Instrumentation and Detectors · Physics 2009-11-11 P. Fonte , T. Francke , N. Pavlopoulos , V. Peskov , I. Rodionov

Photosensitive gaseous detectors with a simple photoelectron multiplication mechanism as resistive plate chambers are expected to offer both large photo coverage and excellent time resolution while keeping costs low. We have developed a…

Instrumentation and Detectors · Physics 2025-02-25 R. Okubo , K. Matsuoka , T. Iijima , K. Inami , Y. Horii , K. Suzuki , K. Sumi , T. Ichikawa , K. Ueda , S. Koji , A. Kondo , K. Chiba

Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a…

The Multigap Resistive Plate Chambers (MRPCs) provide excellent timing as well as position resolutions at relatively low cost. Therefore, they can be used in medical imaging applications such as PET where precise timing is a crucial…

Instrumentation and Detectors · Physics 2019-07-23 M. Nizam , B. Satyanarayana , R. R. Shinde , G. Majumder

The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its…

The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of…

Instrumentation and Detectors · Physics 2016-09-21 F. Lagarde , M. Gouzevitch , I. Laktineh , V. Buridon , X. Chen , C. Combaret , A. Eynard , L. Germani , G. Grenier , H. Mathez , L. Mirabito , A. Petrukhin , A. Steen , W. Tromeuraa , Y. Wang , A. Gongab , N. Moreau , C. de la Taille , F. Dulucqac , A. Cimmino , S. Crucy , A. Fagot , M. Gul , A. A. O. Rios , M. Tytgat , N. Zaganidisb , S. Aly , Y. Assran , A. Radi , A. Sayedc , G. Singhd , M. Abbrescia , G. Iaselli , M. Maggi , G. Pugliese , P. Verwilligene , W. Van Doninck , S. Colafranceschi , A. Sharmag , L. Benussi , S. Bianco , D. Piccolo , F. Primaverah , V. Bhatnagar , R. Kumari , A. Mehta , J. Singhi , A. Ahmad , W. Ahmed , H. M. I. Asghar , I. M. Awan , R. Hoorani , S. Muhammad , H. Shahzad , M. A. Shah , S. W. Cho , S. Y. Choi , B. Hong , M. H. Kang , K. S. Lee , J. H. Lim , S. K. Parkk , M. S. Kiml , S. Carpinteyro Bernardino , I. Pedraza , C. Uribe Estradam , S. Carrillo Moreno , F. Vazquez Valencian , L. M. Panto , S. Buontempo , N. Cavallo , M. Esposito , F. Fabozzi , G. Lanza , I. Orso , L. Lista , S. Meola , M. Merola , P. Paolucci , F. Thyssen , A. Braghieri , A. Magnani , P. Montagna , C. Riccardi , P. Salvini , I. Vai , P. Vituloq , Y. Ban , S. J. Qianr , M. Choi , Y. Choi , J. Goh , D. Kimt , A. Aleksandrov , R. Hadjiiska , P. Iaydjiev , M. Rodozov , S. Stoykova , G. Sultanov , M. Vutovau , A. Dimitrov , L. Litov , B. Pavlov , P. Petkovv , I. Bagaturia , D. Lomidzew , C. Avila , A. Cabrera , J. C. Sanabria , I. Crottyy , J. Vaitkusz

We performed a new series of systematic studies of gain and rate characteristics of several micropattern gaseous detectors. Extending earlier studies, these measurements were done at various pressures, gas mixtures, at a wide range of…

Instrumentation and Detectors · Physics 2007-05-23 V. Peskov , P. Fonte , M. Danielsson , C. Iacobaeus , J. Ostling , M. Wallmark

The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of…

Multi-gap RPC prototypes with readout on a multi-strip electrode were developed for the small polar angle region of the CBM-TOF subdetector, the most demanding zone in terms of granularity and counting rate. The prototypes are based on low…

Dedicated detector simulations are very important for the success of high energy physics experiments. They not only bring benefits to the optimization of the detectors, but can also improve the precision of the physics results. To design a…

Instrumentation and Detectors · Physics 2018-09-26 Fuyue Wang , Dong Han , Yi Wang , Yancheng Yu , Qiunan Zhang , Baohong Guo , Yuanjing Li

The Multigap Resistive Plate Chambers (MRPC) are used as a timing detector in several particle physics and cosmic ray experiments. The gas mixture of MRPC at current experiments is a mixture containing $\rm C_2F_4H_2$ and in some cases $\rm…

Instrumentation and Detectors · Physics 2020-01-29 Baek Yongwook , Kim Do-won , Park Woosung , Williams Crispin , Zuyeuski Roman