English
Related papers

Related papers: A high rate and high timing photoelectric detector…

200 papers

A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6 to 2.5 volt amplitude,…

Resistive plate chambers (RPC) lined with $^{10}B_{4}$C neutron converters is a promising cost effective technology for position-sensitive thermal neutron detection capable to outperform $^{3}$He-based detectors in terms of spatial…

Instrumentation and Detectors · Physics 2020-08-26 L. M. S. Margato , A. Morozov , A. Blanco , P. Fonte , L. Lopes , K. Zeitelhack , R. Hall-Wilton , C. Höglund , L. Robinson , S. Schmidt , P. Svensson

The Micro-Pattern Gaseous Detectors offer excellent spatial and temporal resolution in harsh radiation environments of high-luminosity colliders. In this work, an attempt has been made to establish an algorithm for estimating the time…

Instrumentation and Detectors · Physics 2016-05-11 Purba Bhattacharya , Nayana Majumdar , Supratik Mukhopadhyay , Sudeb Bhattacharya

A four-gap glass RPC with 0.3mm gap size was tested with hadron beam as a time-of-flight detector having a time resolution of ~ 100ps. A thickness of the detector together with front-end electronics is ~ 12mm. Results on time resolution…

High Energy Physics - Experiment · Physics 2007-05-23 V. Ammosov , V. Gapienko , A. Semak , V. Senko , Yu. Sviridov , V. Zaets , E. Usenko

The multi-pixel photon counter (MPPC) is a newly developed photodetector with an excellent photon counting capability. It also has many attractive features such as small size, high gain, low operation voltage and power consumption, and…

A challenging goal of 20 ps for the total time resolution of the Multi-gap Resistive Plate Chambers (MRPCs) system has been recently addressed by high energy physics experiments. In order to meet this requirement, one should have a deeper…

Instrumentation and Detectors · Physics 2019-10-15 Fuyue Wang , Dong Han , Yi Wang , Pengfei Lyu , Yuanjing Li

To achieve high-resolution muography of compact targets in scenarios with complex logistical constraints, we are developing a portable muon detector system utilizing glass Resistive Plate Chambers (RPCs). Although RPCs are well understood…

This communication describes test beam results, focusing on detection efficiency and timing precision, of common float glass timing Resistive Plate Chambers (tRPCs) exposed to a $2.7$~GeV proton beam and operated at above ambient…

Instrumentation and Detectors · Physics 2022-11-23 A. Blanco , P. Fonte , L. Lopes , J. Saraiva

A hybrid readout Time Projection Chamber (TPC) has a simultaneous optical- and charge readout. The optical readout provides 2D images of particle tracks in the active volume, whilst the charge readout provides additional information on the…

Instrumentation and Detectors · Physics 2022-12-21 Alexander Deisting

This experimental particle-physics thesis reports the latest developments on the GasPM, a novel gaseous photodetector aimed at suppressing beam-induced backgrounds in the electromagnetic calorimeter for a potential upgrade of the Belle~II…

Instrumentation and Detectors · Physics 2026-05-20 Simone Garnero

Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in…

Instrumentation and Detectors · Physics 2015-09-08 M. Affatigato , U. Akgun , B. Bilki , F. Corriveau , B. Freund , N. Johnson , C. Neubueser , Y. Onel , J. Repond , L. Xia

The PICOSEC detection concept consists in a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. A proof of concept has already been tested: a single-photoelectron response of 76 ps has been…

The detailed simulation of the Multi-gap Resistive Plate Chambers (MRPCs) provides the performance characteristics of MRPCs with different numbers of gas gaps and gap thicknesses. This helps in optimizing the structure of MRPCs under…

Instrumentation and Detectors · Physics 2024-12-31 J. Liu , Z. Chen , Y. Wang , B. Guo , D. Han , Y. Li

Recent advances in photon detectors have resulted in high-density imaging arrays that offer many performance and cost advantages. In particular, the excellent transit time spread of certain devices show promise to provide tangible benefits…

Instrumentation and Detectors · Physics 2009-04-17 Gary S. Varner , Larry L. Ruckman

The Resistive Plate Chambers (RPC) are low-cost charged-particle detectors with good timing resolution and potentially good spatial resolution. Using RPC as gamma detector provides an opportunity for application in positron emission…

Instrumentation and Detectors · Physics 2014-02-20 Zhou Weizheng , Shao Ming , Li Cheng , Chen Hongfang , Sun Yongjie , Chen Tianxiang

The current state of the art in fast timing resolution for existing experiments is of the order of 100 ps on the time of arrival of both charged particles and electromagnetic showers. Current R&D on charged particle timing is approaching…

We are developing a new photon detector with micro pattern gaseous detectors. A semitransparent CsI photocathode is combined with 10cm$\times$10cm GEM/$\mu$PIC for the first prototype which is aimed for the large liquid Xe detectors. Using…

Astrophysics · Physics 2013-03-20 H. Sekiya

Here we report on a particular type of RPC that presents up to 99% efficiency for minimum ionizing particles and a very sharp time resolution, below 50 ps sigma in the most optimized conditions. Our 9 cm2 cells, made with glass and metal…

Instrumentation and Detectors · Physics 2009-10-31 P. Fonte , R. Ferreira Marques , J. Pinhao , N. Carolino , A. Policarpo

Single gap (gas gap 2 mm) bakelite Resistive Plate Chamber (RPC) modules of various sizes from 10 cm \times 10 cm to 1 m \times 1 m have been fabricated, characterized and optimized for efficiency and time resolution. Thin layers of…

Instrumentation and Detectors · Physics 2015-06-05 K. K. Meghna , A. Banerjee , S. Biswas , S. Bhattacharya , S. Bose , S. Chattopadhyay , G. Das , C. Marick , S. Saha , Y. P. Viyogi