Related papers: Demonstrating sub-electron noise performance in Si…
We compare charge transitions on a deterministic single P donor in silicon using radio frequency reflectometry measurements with a tunnel coupled reservoir and DC charge sensing using a capacitively coupled single electron transistor (SET).…
The \emph{MIDNA} application specific integrated circuit (ASIC) is a skipper-CCD readout chip fabricated in a 65 nm LP-CMOS process that is capable of working at cryogenic temperatures. The chip integrates four front-end channels that…
The operation of solid-state qubits often relies on single-shot readout using a nanoelectronic charge sensor, and the detection of events in a noisy sensor signal is crucial for high fidelity readout of such qubits. The most common…
In order to achieve the challenging requirements on the CLIC vertex detector, a range of technology options have been considered in recent years. One prominent idea is the use of active sensors implemented in a commercial high-voltage CMOS…
Since the discovery of electrons, an accurate detection of electrical charges has been the dream of scientific community. Due to some remarkable advantages, micro/nano-electromechanical systems (M/NEMS) based resonators have been used to…
Telegraph noise, which originates from the switching of charge between meta-stable trapping sites, becomes increasingly important as device sizes approach the nano-scale. For charge-based quantum computing, this noise may lead to…
This paper presents a millimeter-scale CMOS 64$\times$64 single charged particle radiation detector system for external beam cancer radiotherapy. A 1$\times$1 $\mu m^2$ diode measures energy deposition by a single charged particle in the…
For the upgrade of the inner tracker of the BESIII spectrometer, planned for 2018, a lightweight tracker based on an innovative Cylindrical Gas Electron Multiplier (CGEM) detector is now under development. The analogue readout of the CGEM…
PARISROC is a complete read out chip, in AMS SiGe 0.35 micron technology [1], for photomultipliers array. It allows triggerless acquisition for next generation neutrino experiments and it belongs to an R&D program funded by the French…
We report on low-temperature noise measurements of a single electron transistor (SET) immersed in superfluid $^4$He. The device acts as a charge sensitive electrometer able to detect the fluctuations of charged defects in close proximity to…
A monolithic silicon pixel detector prototype has been produced in the SiGe BiCMOS SG13G2 130 nm node technology by IHP. The ASIC contains a matrix of hexagonal pixels with pitch of approximately 100 $\mu$m. Three analog pixels were…
This paper presents a first study of the performance of a novel 2D position-sensitive microstrip detector, where the resistive charge division method was implemented by replacing the metallic electrodes with resistive electrodes made of…
We present a compact on-chip resonator enhanced silicon-MSM photodetector in $850$ $nm$ wavelength band for communication and lab-on-chip bio-sensing applications. We report the highest responsivity of 0.81 A/W for a 5 $\mu m$ long device.…
We demonstrate first experimental investigation on the performance of a single-node reservoir computer based on a silicon microring resonator (MRR) operating on the digit recognition task. The input layer of the reservoir is composed of a…
We present the development of a single-photon detector and the connected read-out electronics. This `hybrid' detector is based on a vacuum tube, transmission photocathode, microchannel plate and a pixelated CMOS read-out anode encapsulating…
A CMOS pixel sensor, named Supix-1, is developed for a pixelated silicon tracker for the Circular Electron-Positron Collider (CEPC) project. The sensor, consisted of nine sectors varying in pixel sizes, diode sizes and geometries, is…
Single-photon detectors based on the superconducting transition-edge sensor are used in a number of visible to near-infrared applications, particularly for photon-number-resolving measurements in quantum information science. To be practical…
We report on the realization of a high sensitivity RF noise measurement scheme to study small current fluctuations of mesoscopic systems at milliKelvin temperatures. The setup relies on the combination of an interferometric ampli- fication…
We present a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This type of charge-coupled device (CCD) sensor features multiple in-line amplifiers…
We report on the assessment of the imaging performance of CITIUS -- a high-speed X-ray detector developed for the large-scale synchrotron radiation facility SPring-8-II -- for heavy charged particles and neutrons. To characterize the…