Related papers: Proton discrimination in CLYC for fast neutron spe…
In beam test experiments have been carried out for particle identification using digital pulse shape analysis in a 500~$\mu$m thick Neutron Transmutation Doped (nTD) silicon detector with an indigenously developed FPGA based 12 bit…
In this contribution we report on further investigations of the recently-evaluated Constant-Fraction Time-over-Threshold (CF-ToT) method for neutron/gamma-ray pulse shape discrimination (PSD). The superiority of the CF-ToT PSD method over…
Chromatic calorimetry (CCAL) analyses particle detection by utilizing scintillators with distinct emission wavelengths to measure the longitudinal energy deposition of particle showers in high-energy physics, improving particle…
Digital pulse shape discrimination has become readily available to distinguish nuclear recoil and electronic recoil events in scintillation detectors. We evaluate digital implementations of pulse shape discrimination algorithms discussed in…
We report on the development of a fast neutron detector using a liquid scintillator doped with enriched Li-6. The lithium was introduced in the form of an aqueous LiCl micro-emulsion with a di-isopropylnaphthalene-based liquid scintillator.…
Pressurized Helium-4 (PHe) based fast neutron scintillation detector offers an useful alternative to organic liquid-based scintillator due to its relatively low response to the $\gamma$-rays compared to the latter type of scintillator. In…
The Compact Linear Collider (CLIC) is a mature option for a future electron-positron collider operating at centre-of-mass energies of up to 3 TeV. CLIC will be built and operated in a staged approach with three centre-of-mass energies…
Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…
We report on the response of a high light-output NaI(Tl) crystal to nuclear recoils induced by neutrons from an Am-Be source and compare the results with the response to electron recoils produced by Compton scattered 662 keV $\gamma$-rays…
CLLBC(Ce) and TLYC(Ce) are novel scintillation materials capable of measuring mixed gamma ray and neutron radiation fields that have gained significant interest in the areas of space and nuclear safety/security science. To date Geant4, the…
The Compact Linear Collider (CLIC) is a proposed future high-luminosity linear electron-positron collider operating at three energy stages, with nominal centre-of-mass energies: 380 GeV, 1.5 TeV, and 3 TeV. Its aim is to explore the energy…
Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified…
A large area (0.5~m $\times$ 0.5~m) thermal neutron detector was developed based on 0.32~mm-thick $^{6}$LiF:ZnS(Ag) scintillator sheets. The detector was constructed for measurements of seasonal variations in low intensity thermal neutron…
Two detection systems based on optical readout were developed: a. Integrative optical detector A 2nd generation of Time-Resolved Integrative Optical Neutron (TRION) detector was developed. It is based on an integrative optical technique,…
There are recent interests with CsI(Tl) scintillating crystals for Dark Matter experiments. The scattering signatures by neutrons on a CsI(Tl) detector were studied using a neutron beam generated by a 13 MV Tandem accelerator. The energy…
A meter-long, 23-liter EJ-309 liquid scintillator detector has been constructed to study the light collection and pulse-shape discrimination performance of elongated scintillator cells for the PROSPECT reactor antineutrino experiment. The…
The publicly accessible dataset includes neutron and gamma-ray pulse signals for conducting pulse shape discrimination experiments. Several traditional and recently proposed pulse shape discrimination algorithms are utilized to evaluate the…
The ALICE experiment features multiple particle identification systems. The measurement of the identified charged hadron $p_{t}$ spectra in proton-proton collisions at $\sqrt{s}=900$ GeV will be discussed. In the central rapidity region…
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e$^+$e$^-$-collider under development by the CLIC accelerator collaboration, hosted by CERN. The CLIC accelerator has been optimised for three energy stages at…
This letter explains a new, highly sensitive method for the detection of neutrons, which uses the T$_{1/2}=845$ ns delay in the decay of $^{128}$I at the 137.8 keV energy level, resulting from the capture of thermal neutrons by iodine…