English
Related papers

Related papers: Collimator-less SPECT System Design for Dynamic Wh…

200 papers

X-ray and gamma-ray polarimetry is a promising tool to study the geometry and the magnetic configuration of various celestial objects, such as binary black holes or gamma-ray bursts (GRBs). However, statistically significant polarizations…

X-ray energy spectrum plays an essential role in computed tomography (CT) imaging and related tasks. Due to the high photon flux of clinical CT scanners, most of spectrum estimation methods are indirect and usually suffered from various…

Medical Physics · Physics 2017-06-14 Wei Zhao , Lei Xing , Qiude Zhang , Qingguo Xie , Tianye Niu

Single-Photon Emission Computed Tomography (SPECT) is widely applied for the diagnosis of ischemic heart diseases. Low-dose (LD) SPECT aims to minimize radiation exposure but leads to increased image noise. Limited-angle (LA) SPECT enables…

Computer Vision and Pattern Recognition · Computer Science 2023-05-18 Xiongchao Chen , Bo Zhou , Huidong Xie , Xueqi Guo , Qiong Liu , Albert J. Sinusas , Chi Liu

PET is a functional imaging technique based on detection of annihilation photons following beta decay producing positrons. In this paper, we present the concept of a new PET system for preclinical applications consisting of a ring of twelve…

Instrumentation and Detectors · Physics 2015-03-19 A. Miceli , P. Amaudruz , F. Benard , D. A. Bryman , L. Kurchaninov , J. P. Martin , A. Muennich , F. Retiere , T. J. Ruth , V. Sossi , A. J. Stoessl

We present the first INTEGRAL observations of the type 1.5 Seyfert galaxy NGC 4151. Combining several INTEGRAL observations performed during 2003, totaling about 400 ks of exposure time, allows us to study the spectrum in the 2 - 300 keV…

The gamma-ray energy range from a few hundred keV to a few hundred MeV has remained largely unexplored, mainly due to the challenging nature of the measurements, since the pi- oneering, but limited, observations by COMPTEL on the Compton…

Photon attenuation and scatter are the two main physical factors affecting the diagnostic quality of SPECT in its applications in brain imaging. In this work, we present a novel Bayesian Optimization approach for Attenuation Correction…

Medical Physics · Physics 2021-09-27 Loizos Koutsantonis , Ayman Makki , Tiago Carneiro , Emmanuel Kieffer , Pascal Bouvry

Calibration of the absolute energy scale at high-energy photon (gamma-gamma, gamma-electron) colliders is discussed. The luminosity spectrum at photon colliders is broad and has a rather sharp high-energy edge, which can be used, for…

Accelerator Physics · Physics 2015-06-22 V. I. Telnov

PET imaging is a non-invasive technique for particle range verification in proton therapy. It is based on measuring the beta+ annihilations caused by nuclear interactions of the protons in the patient. In this work we present measurements…

We have been developing a semiconductor Compton telescope to explore the universe in the energy band from several tens of keV to a few MeV. We use a Si strip and CdTe pixel detector for the Compton telescope to cover an energy range from 60…

LXeGRIT is a balloon-borne Compton telescope based on a liquid xenon time projection chamber (LXeTPC) for imaging cosmic \g-rays in the energy band of 0.2-20 MeV. The detector, with 400 cm$^2$ area and 7 cm drift gap, is filled with high…

The methods to measure the polarization of the x-rays from highly charged heavy ions with a significantly higher accuracy than the existing technology is needed to explore relativistic and quantum electrodynamics (QED) effects including the…

Range uncertainties in proton therapy hamper treatment precision. Prompt gamma-rays were suggested 16 years ago for real-time range verification, and have already shown promising results in clinical studies with collimated cameras.…

Medical Physics · Physics 2021-12-07 F. Hueso-González , T. Bortfeld

Active Target Time Projection Chambers (AT-TPCs) are state-of-the-art tools in the field of low-energy nuclear physics, particularly suitable for experiments using low-intensity radioactive ion beams or gamma rays. The Fudan Multi-purpose…

SPECT provides a mechanism to perform absorbed-dose quantification tasks for $\alpha$-particle radiopharmaceutical therapies ($\alpha$-RPTs). However, quantitative SPECT for $\alpha$-RPT is challenging due to the low number of detected…

Study of high energy cosmic events in the MeV range requires detector with high efficiency and energy resolution to be constructed. The present setup consisting of scintillator crystals CeBr3 with different thickness, each coupled with 12 x…

Instrumentation and Detectors · Physics 2025-12-10 Veronika Asova , Galin Bistrev , Simeon Ivanov

Objective: To propose a CBCT dose optimization method using readily available measurement equipment in radiation oncology departments. Approach: A 0.6cc air kerma (Kair) calibrated Farmer chamber measured Kair at isocenter for five default…

Medical Physics · Physics 2025-02-04 S. Gros , J. Bian , J. Jackson , M. Delafuente , H. Kang , W. Small , M. Mahesh

We developed a novel gamma-ray detection system (TIARA) for range monitoring in Particle Therapy. The system employs Cherenkov-based gamma-ray detection modules arranged around the target or patient, operated in time coincidence with a fast…

The Soft Gamma-ray Detector (SGD), to be deployed onboard the {\it ASTRO-H} satellite, has been developed to provide the highest sensitivity observations of celestial sources in the energy band of 60-600~keV by employing a detector concept…

Thorium-227-based alpha-particle radiopharmaceutical therapies ({\alpha}-RPTs) are being investigated in several clinical and pre-clinical studies. After administration, Thorium-227 decays to Radium-223, another alpha-particle-emitting…

‹ Prev 1 4 5 6 7 8 10 Next ›