Related papers: Noise And Artifacts Elimination In ECG Signals Usi…

200 papers

Electrocardiogram (ECG) signal is an important physiological signal which contains cardiac information and is the basis to diagnosis cardiac related diseases. In this paper, several innovative and efficient methods based on adaptive filter…

Signal Processing · Electrical Eng. & Systems 2021-08-20 Bingze Dai , Wen Bai

Electroencephalogram (EEG) signals may get easily contaminated by muscle artifacts, which may lead to wrong interpretation in the brain--computer interface (BCI) system as well as in various medical diagnoses. The main objective of this…

Signal Processing · Electrical Eng. & Systems 2022-04-15 Souvik Phadikar , Nidul Sinha , Rajdeep Ghosh , Ebrahim Ghaderpour

ECG signals are usually corrupted by baseline wander, power-line interference, muscle noise, etc. and numerous methods have been proposed to remove these noises. However, in case of wireless recording of the ECG signal it gets corrupted by…

Applications · Statistics 2016-11-11 Santosh Kumar Yadav , Rohit Sinha , Prabin Kumar Bora

We propose a novel deep learning based denoising filter selection algorithm for noisy Electrocardiograph (ECG) signal preprocessing. ECG signals measured under clinical conditions, such as those acquired using skin contact devices in…

Signal Processing · Electrical Eng. & Systems 2022-02-02 Chandresh Pravin , Varun Ojha

Wearable electrocardiogram (ECG) measurement using dry electrodes has a problem with high-intensity noise distortion. Hence, a robust noise reduction method is required. However, overlapping frequency bands of ECG and noise make noise…

Signal Processing · Electrical Eng. & Systems 2025-01-14 Takamasa Terada , Masahiro Toyoura

Electroencephalogram (EEG) signals are often corrupted with unintended artifacts which need to be removed for extracting meaningful clinical information from them. Typically a priori knowledge of the nature of the artifacts is needed for…

Medical Physics · Physics 2018-03-02 Valentina Bono , Saptarshi Das , Wasifa Jamal , Koushik Maharatna

Varieties of noises are major problem in recognition of Electromyography (EMG) signal. Hence, methods to remove noise become most significant in EMG signal analysis. White Gaussian noise (WGN) is used to represent interference in this…

Computer Vision and Pattern Recognition · Computer Science 2009-12-26 Angkoon Phinyomark , Chusak Limsakul , Pornchai Phukpattaranont

Electrocardiograms (ECGs) are vital for monitoring cardiac health, enabling the assessment of heart rate variability (HRV), detection of arrhythmias, and diagnosis of cardiovascular conditions. However, ECG signals recorded from wearable…

Machine Learning · Computer Science 2025-12-17 Sharmad Kalpande , Nilesh Kumar Sahu , Haroon Lone

Electrocardiogram (ECG) artifact contamination often occurs in surface electromyography (sEMG) applications when the measured muscles are in proximity to the heart. Previous studies have developed and proposed various methods, such as…

Signal Processing · Electrical Eng. & Systems 2022-10-25 Kuan-Chen Wang , Kai-Chun Liu , Sheng-Yu Peng , Yu Tsao

In order to reduce the muscle artifacts in multi-channel pervasive Electroencephalogram (EEG) signals, we here propose and compare two hybrid algorithms by combining the concept of wavelet packet transform (WPT), empirical mode…

Medical Physics · Physics 2014-10-22 Valentina Bono , Wasifa Jamal , Saptarshi Das , Koushik Maharatna

Electrocardiogram (ECG) signals are frequently corrupted by noise, such as baseline wander (BW), muscle artifacts (MA), and electrode motion (EM), which significantly degrade their diagnostic utility. To address this issue, we propose…

Signal Processing · Electrical Eng. & Systems 2025-05-12 Sainan xiao , Wangdong Yang , Buwen Cao , Jintao Wu

Wavelet quantile normalization (WQN) is a nonparametric algorithm designed to efficiently remove transient artifacts from single-channel EEG in real-time clinical monitoring. Today, EEG monitoring machines suspend their output when…

Methodology · Statistics 2022-08-04 Matteo Dora , Stéphane Jaffard , David Holcman

Electroencephalogram (EEG) artifact detection in real-world settings faces significant challenges such as computational inefficiency in multi-channel methods, poor robustness to simultaneous noise, and trade-offs between accuracy and…

Machine Learning · Computer Science 2025-10-10 Hossein Enshaei , Pariya Jebreili , Sayed Mahmoud Sakhaei

Introduction: Electroencephalogram (EEG) signals have gained significant popularity in various applications due to their rich information content. However, these signals are prone to contamination from various sources of artifacts, notably…

Signal Processing · Electrical Eng. & Systems 2023-08-28 Behrad TaghiBeyglou , Fatemeh Bagheri

Electrocardiography (ECG) signals are frequently degraded by noise, limiting their clinical reliability in both conventional and wearable settings. Existing methods for addressing ECG noise, relying on artifact classification or denoising,…

Signal Processing · Electrical Eng. & Systems 2025-07-23 Tae-Seong Han , Jae-Wook Heo , Hakseung Kim , Cheol-Hui Lee , Hyub Huh , Eue-Keun Choi , Hye Jin Kim , Dong-Joo Kim

Electroencephalographic (EEG) signals are fundamental to neuroscience research and clinical applications such as brain-computer interfaces and neurological disorder diagnosis. These signals are typically a combination of neurological…

Machine Learning · Computer Science 2023-10-27 Matteo Gabardi , Aurora Saibene , Francesca Gasparini , Daniele Rizzo , Fabio Antonio Stella

Electrohysterography (EHG) enables non-invasive monitoring of uterine contractions but can be contaminated by electrocardiogram (ECG) artifacts. This work presents an ECG removal method using algebraic differentiators, a control-theoretic…

Systems and Control · Electrical Eng. & Systems 2026-03-20 Amine Othmane , Maria Camila Bustos Vivas , Johannes Steuer , Jana Hutter

Electroencephalogram (EEG) recordings are often contaminated with artifacts. Various methods have been developed to eliminate or weaken the influence of artifacts. However, most of them rely on prior experience for analysis. Here, we…

Machine Learning · Computer Science 2022-02-22 Junjie Yu , Chenyi Li , Kexin Lou , Chen Wei , Quanying Liu

There are many sources of interference encountered in the electroencephalogram (EEG) recordings, specifically ocular, muscular, and cardiac artifacts. Rejection of EEG artifacts is an essential process in EEG analysis since such artifacts…

Image and Video Processing · Electrical Eng. & Systems 2020-09-21 Najmeh Mashhadi , Abolfazl Zargari Khuzani , Morteza Heidari , Donya Khaledyan

Nowadays, the electrocardiogram (ECG) is still the most widely used signal for the diagnosis of cardiac pathologies. However, this recording is often disturbed by the powerline interference (PLI), its removal being mandatory to avoid…

Signal Processing · Electrical Eng. & Systems 2024-01-22 Juan Rodenas , Manuel Garcia , Jose J. Rieta , Raul Alcaraz