Related papers: A Method of Measuring TES Complex ETF Response in …
We present an experimental instrument that performs laboratory-based gas-phase Terahertz Desorption Emission Spectroscopy (THz-DES) experiments in support of astrochemistry. The measurement system combines a terahertz heterodyne radiometer…
We develop a compact transmon emitter/detector (TED) superconducting circuit and demonstrate its dual functionality as a single-photon source and detector. In our setup, photons emitted by a source TED are transmitted via a meter-long…
We describe an FPGA based Front-End Data Acquisition Module (FEDAM) for implementing Time-over-Threshold (ToT) Time-to-Digital conversion (TDC) of pulses obtained from the COSMICi astroparticle telescope detector system photomultiplier…
The electric dipole moment of the electron (eEDM) can be measured with high precision using heavy polar molecules. In this paper, we report on a series of new techniques that have improved the statistical sensitivity of the YbF eEDM…
We present an efficient and systematically convergent approach to all-electron real-time time-dependent density functional theory (TDDFT) calculations using a mixed basis, termed as enriched finite element (EFE) basis. The EFE basis…
The readout of transition-edge sensor (TES) bolometers with a large multiplexing factor is key for the next generation Cosmic Microwave Background (CMB) experiment, Polarbear-2, having 7,588 TES bolometers. To enable the large arrays, we…
The dynamical mean-field theory (DMFT) combined with the fluctuation exchange (FLEX) method, namely FLEX+DMFT, is an approach for correlated electron systems to incorporate both local and non-local long-range correlations in a…
This work is proposing and exploring the use of multichannel readout electronics, already used in quality assurance for gain uniformity studies, to measure the uniformity of the induction gap in GEM based detectors. The measurement will…
Ambulatory electrocardiogram (ECG) readings are prone to mixed noise from physical activities, including baseline wander (BW), muscle artifact (MA), and electrode motion artifact (EM). Developing a method to remove such complex noise and…
Transition-edge sensors are a type of superconducting detector that offers high energy resolution based on their sharp resistance-temperature feature in the superconducting-to-normal transition. TES X-ray microcalorimeters have typically…
We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m squared, AuBi…
We propose and demonstrate wide-band capacitance measurements on a semiconductor double-quantum dot (DQD) to study tunneling dynamics. By applying phase-tunable high-frequency signals independently to the DQD and a nearby…
In this work, we demonstrate the generation of sidebands in electromagnetically induced transparency (EIT) signal due to frequency modulation of Rydberg states in $^{87}\text{Rb}$ thermal vapor. An oscillating radio-frequency (RF) electric…
We show that the sensitivity of antenna-coupled field-effect transistors (FETs) to terahertz (THz) radiation improves continuously with decreasing temperature. The noise-equivalent power (NEP) of 540 GHz patch-antenna-coupled FETs decreases…
An important desired ingredient of superconducting quantum circuits is a readout scheme whose complexity does not increase with the number of qubits involved in the measurement. Here, we present a readout scheme employing a single microwave…
The influence of temperature is a major problem in Structural Health Monitoring diagnosis using guided waves. In this article, two methods for temperature compensation are used to evaluate the temperature of a structure monitored by…
SRON (Netherlands Institute for Space Research) is developing the Focal Plane Assembly (FPA) for Athena X-IFU, whose Demonstration Model (DM) will use for the first time a time domain multiplexing (TDM)-based readout system for the on-board…
In this study, a time-domain reflectometry (TDR) system based on a baseband version of the orthogonal chirp-division multiplexing (OCDM) scheme, which is relies on a modified discrete Fresnel transform (DFnT), is proposed for power line…
We present measurements of the ac response of a single-electron box (SEB). We apply an rf signal with a frequency larger than the tunneling rate and drive the system out of equilibrium. We observe much more dissipation in the SEB then one…
We are developing large TES arrays in combination with FDM readout for the next generation of X-ray space observatories. For operation under AC-bias, the TESs have to be carefully designed and optimized. In particular, the use of high…