Related papers: Noise Suppression with Cryogenic Resonators
This article shows the first measurement of three 100 MHz signals exhibiting fluctuations from 2E-16 to parts in 1E-15 for integration time tau between 1 s and 1 day. Such stable signals are provided by three Cryogenic Sapphire Oscillators…
A vacuum compatible cryogenic accelerometer is presented which will reach $<0.5$ p$g$ Hz$^{-1/2}$ sensitivity from 1 mHz to 10 Hz with a maximum sensitivity of 10 f$g$ Hz$^{-1/2}$ around 10 Hz. This figure can be translated to a…
We report in this letter the outstanding frequency stability performances of an autonomous cryogenique sapphire oscillator presenting a flicker frequency noise floor below 2e-16 near 1,000 s of integration time and a long term Allan…
Microwave circuit electrodynamics of disordered superconductors is a very active research topic spawning a wide range of experiments and applications. For compact superconducting circuit elements, the transition to an insulating state poses…
Progress in the emerging field of engineered quantum systems requires the development of devices that can act as quantum memories. The realisation of such devices by doping solid state cavities with paramagnetic ions imposes a trade-off…
Under negative feedback, the quality factor Q of a radio-frequency magnetometer can be decreased by more than two orders of magnitude, so that any initial perturbation of the polarized spin system can be rapidly damped, preparing the…
We present our first experimental determination of the magnetic noise of a superspinglass made of < 1 pico-liter frozen ferrofluid. The measurements were performed with a local magnetic field sensor based on Hall microprobes operated with…
We report pulsed electron-spin resonance (ESR) measurements on an ensemble of Bismuth donors in Silicon cooled at 10mK in a dilution refrigerator. Using a Josephson parametric microwave amplifier combined with high-quality factor…
We measure the current noise of several cryogenic cables in a pulse tube based dilution refrigerator at frequencies between about 1~mHz and 50~kHz. We show that vibration-induced noise can be efficiently suppressed by using vacuum-insulated…
We test the fluctuation-dissipation relation (FDR) in spin ice materials Dy$_2$Ti$_2$O$_7$ and Ho$_2$Ti$_2$O$_7$ by measuring both the magnetic noise and the out-of-phase part of the susceptibility and comparing their ratio. We show that it…
We have measured the low frequency (1mHz<f<10Hz) resistance fluctuations in metallic nanowires (diameter 15nm to 200nm) in the temperature range 77K to 400K. The nanowires were grown electrochemically in polycarbonate membranes and the…
Here, we study the paramagnetic ions behavior in presence of a strong microwave electromagnetic field sustained inside a cryogenic sapphire whispering gallery mode resonator. The high frequency measurement resolution that can be now…
Vacuum fluctuations of the electromagnetic field set a fundamental limit to the sensitivity of a variety of measurements, including magnetic resonance spectroscopy. We report the use of squeezed microwave fields, which are engineered…
Nano- and micromechanical oscillators with high quality (Q) factors have gained much attention for their potential application as ultrasensitive detectors. In contrast to micro-fabricated devices, optically trapped nanoparticles in vacuum…
We have developed a low temperature, high-resolution microwave surface impedance probe that is able to operate in high static magnetic fields. Surface impedance is measured by cavity perturbation of dielectric resonators, with sufficient…
Carbon nanotube mechanical resonators have attracted considerable interest because of their small mass, the high quality of their surface, and the pristine electronic states they host. However, their small dimensions result in fragile…
This article reports the design, the breadboarding and the validation of an ultra-stable Cryogenic Sapphire Oscillator operated in an autonomous cryocooler. The objective of this project was to demonstrate the feasibility of a frequency…
The accuracy of microwave measurements is not only critical for applications in telecommunication and radar, but also for future quantum computers. Qubit technologies such as superconducting qubits or spin qubits require detecting minuscule…
We describe the measurement and modeling of amplitude noise and phase noise in ultra-high Q nanomechanical resonators made from stoichiometric silicon nitride. With quality factors exceeding 2 million, the resonators' noise performance is…
KAGRA uses cryogenics to cool its sapphire test masses down to 20 K to reduce the thermal noise. However, cryocooler vibration and structural resonances of the cryostat couple to test mass and can contaminate the detector sensitivity. We…