Related papers: Ultra-Cold Cryogenic TEM with Liquid Helium and Hi…
Buffer gas cooling with a $^4$He gas is used to perform laser-absorption spectroscopy of the $^{12}$C$_2$H$_2$ ($\nu_1+\nu_3$) band at cryogenic temperatures. Doppler thermometry is first carried out to extract translational temperatures…
We demonstrate that the superconducting critical temperature (Tc) of thin niobium films can be electrically modulated in a liquid-gated geometry device. Tc can be suppressed and enhanced by applying positive and negative gate voltage,…
This paper presents an ultra-low noise L-band radio astronomical cryogenic receiver for FAST telescope. The development of key low noise microwave parts of Coupling-LNA and conical quad-ridge OMT and reasonable system integration achieve…
We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing…
Large arrays of superconducting transition-edge sensor (TES) microcalorimeters are becoming the key technology for future space-based X-ray observatories and ground-based experiments in the fields of astrophysics, laboratory astrophysics,…
We have investigated the possibility of measuring the electron neutrino mass with sub-eV sensitivity by studying the electron capture decay of 163-Ho with cryogenic microcalorimeters. In this paper we will introduce an experiment's concept,…
Transmission electron microscopy has undergone a revolution in recent years with the possibility to perform routine cryo-imaging of biological materials and (bio)chemical systems, as well as the possibility to image liquids via dedicated…
We demonstrate the trapping of millimeter-scale superfluid Helium drops in high vacuum. The drops are sufficiently isolated that they remain trapped indefinitely, cool by evaporation to 330 mK, and exhibit mechanical damping that is limited…
It is shown that under realistic background considerations, an improvement in Cold Dark Matter sensitivity of several orders of magnitude is expected from a detector based on superheated liquid droplets. Such devices are totally insensitive…
The vitrification of aqueous solutions through rapid cooling is a remarkable achievement that launched the field of cryo-electron microscopy (cryo-EM) and has enabled the cryopreservation of biological specimens. For judging the feasibility…
We present a superconducting microresonator thermometer based on two-level systems (TLS) that is drop-in compatible with cryogenic microwave systems. The operational temperature range is 50-1000~mK (which may be extended to 5~mK), and the…
Liquid water is one of the most studied substances, yet many of its properties are difficult to rationalize. The uniqueness of water is rooted in the dynamic network of hydrogen-bonded molecules with relaxation time constants of about one…
We developed an apparatus to couple a 50-micrometer diameter whispering-gallery silica microtoroidal resonator in a helium-4 cryostat using a straight optical tapered-fiber at 1550nm wavelength. On a top-loading probe specifically adapted…
Thermal detectors are a powerful instrument for the search of rare particle physics events. Inorganic crystals are classically used as thermal detectors held in supporting frames made of copper. In this work a novel approach to the…
Replacing the bulky cryoliquid-based cooling stages of cryoenabled instruments by chip-scale refrigeration is envisioned to disruptively reduce the system size similar to microprocessors did for computers. Electronic refrigerators based on…
We have constructed an apparatus to study DC electrical breakdown in liquid helium at temperatures as low as 0.4 K and at pressures between the saturated vapor pressure and $\sim$600 torr. The apparatus can house a set of electrodes that…
We cooled ultrathin tapered fibers to cryogenic temperatures and controllably coupled them with high-Q microsphere resonators at a wavelength close to the optical transition of diamond nitrogen vacancy centers. The 310-nm-diameter tapered…
Laser flash melting and revitrification experiments have recently improved the time resolution of cryo-electron microscopy (cryo-EM) to the microsecond timescale, making it fast enough to observe many of the protein motions that are…
We consider and compare candidate superconducting detector technologies that might be applied to the readout of cavity-axion haloscopes and similar fundamental physics experiments. We conclude that a transition edge sensor (TES) configured…
Cryogenic helium-4 has extremely small kinetic viscosity, which makes it a promising material for high Reynolds ($Re$) number turbulence research in compact laboratory apparatuses. In its superfluid phase (He II), helium has an…