English
Related papers

Related papers: A Four-channel Optically Pumped Magnetometer for a…

200 papers

This work presents an industrially scalable, power-efficient and high-performance quantum magnetometer chip based on proprietary 4H-silicon carbide (SiC) technology, leveraging wafer-scale fabrication techniques to optimize V2 silicon…

We study a resonant interaction of an elliptically polarized light wave with $^{87}$Rb vapor (D$_1$ line) exposed to a transverse magnetic field. A $5$$\times$$5$$\times$$5$~mm$^3$ glass vapor cell is used for the experiments. The wave…

We present a performance analysis of compact monolithic optomechanical inertial sensors that describes their key fundamental limits and overall acceleration noise floor. Performance simulations for low frequency gravity-sensitive inertial…

Instrumentation and Detectors · Physics 2020-07-15 Adam Hines , Logan Richardson , Hayden Wisniewski , Felipe Guzman

In recent years, a two-dimensional (2D) coronal seismology technique applied to spectral-imaging data from the Coronal Multi-channel Polarimeter (CoMP) and UCoMP has enabled routine measurement of the global coronal magnetic field. The…

Solar and Stellar Astrophysics · Physics 2026-01-16 Zihao Yang , Sarah Gibson , Matthias Rempel , Giuliana de Toma

Chip-scale multimode optomechanical systems have unique benefits for sensing, metrology and quantum technologies relative to their single-mode counterparts. Slot-mode optomechanical crystals enable sideband resolution and large…

Magnetic field sensors with high sensitivity and spatial resolution have profoundly impacted diverse applications ranging from geo-positioning and navigation to medical imaging, materials science, and space exploration. However, the use of…

In this work, we report optomechanical coupling, resolved sidebands and phonon lasing in a solid-core microbottle resonator fabricated on a single mode optical fiber. Mechanical modes with quality factors (Q_m) as high as 1.57*10^4 and…

We demonstrate optical pump/THz probe (OPTP) spectroscopy with a variable external magnetic field (0-9 T) in which the time-dependent THz signal is measured by echelon-based single-shot detection at a 1 kHz repetition rate. The method…

We report the performance of a magnetically silent optically pumped cesium magnetometer with a statistical sensitivity of 3.5 pT/rtHz at 1~Hz and a stability of 90 fT over 150 seconds of measurement. Optical pumping with coherent,…

High-frequency atomic force microscopy has enabled extraordinary new science through large bandwidth, high speed measurements of atomic and molecular structures. However, traditional optical detection schemes restrict the dimensions, and…

Mesoscale and Nanoscale Physics · Physics 2014-03-11 C. Doolin , P. H. Kim , B. D. Hauer , A. J. R MacDonald , J. P Davis

Magnetic resonance of sodium fluorescence is studied with varying laser intensity, duty cycle, and field strength. A magnetometer based on sodium vapor cell filled with He buffer gas is demonstrated, which uses a single amplitude-modulated…

Optics · Physics 2018-02-14 Tingwei Fan , Lei Zhang , Xuezong Yang , Shuzhen Cui , Tianhua Zhou , Yan Feng

Optomechanical crystals (OMCs) enable coherent interactions between optical photons and microwave acoustic phonons, and represent a platform for implementing quantum transduction between microwave and optical signals. Optical…

A custom-developed magneto-mechanical resonator (MMR) for wireless pressure measurement is investigated for potential applications in process engineering. The MMR sensor utilises changes in the resonance frequency caused by pressure on a…

A free-induction-decay (FID) type optically-pumped rubidium atomic magnetometer driven by a radio-frequency (RF) magnetic field is presented in this paper. Influences of parameters, such as the temperature of rubidium vapor cell, the power…

Atomic Physics · Physics 2023-01-23 Lulu Zhang , Yongbiao Yang , Ni Zhao , Jun He , Junmin Wang

A new pathway to nuclear magnetic resonance spectroscopy in high pressure diamond anvil cells is introduced, using inductively coupled broadband passive electro-magnetic lenses to locally amplify the magnetic flux at the isolated sample,…

Instrumentation and Detectors · Physics 2017-06-02 Thomas Meier , Nan Wang , Dario Mager , Jan G. Korvink , Sylvain Petigirard , Leonid Dubrovinsky

We report on the design, fabrication, and implementation of ultrasensitive micromechanical oscillators. Our ultrathin single-crystal silicon cantilevers with integrated magnetic structures are the first of their kind: They are fabricated…

Mesoscale and Nanoscale Physics · Physics 2007-05-23 Michelle D. Chabot , John M. Moreland , Lan Gao , Sy-Hwang Liou , Casey W. Miller

An automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on Coherent Population Trapping (CPT) produced by a multi-frequency excitation.…

Atomic Physics · Physics 2014-11-13 J. Belfi , G. Bevilacqua , V. Biancalana , Y. Dancheva , L. Moi

Incorporating functional molecules into sensor devices is an emerging field in molecular electronics that aims at exploiting the sensitivity of different molecules to their environment and turning it into an electrical signal. Among the…

We demonstrate an optically pumped $^{87}$Rb magnetometer in a microfabricated vapor cell based on a zero-field dispersive resonance generated by optical modulation of the $^{87}$Rb ground state energy levels. The magnetometer is operated…

Instrumentation and Detectors · Physics 2015-06-19 Ricardo Jimenez-Martinez , Svenja Knappe , John Kitching

We demonstrate a novel concept for operating graphene-based Hall sensors using an alternating current (AC) modulated gate voltage, which provides three important advantages compared to Hall sensors under static operation: 1) The sensor…

Applied Physics · Physics 2020-02-26 Burkay Uzlu , Zhenxing Wang , Sebastian Lukas , Martin Otto , Max C. Lemme , Daniel Neumaier