Electromagnetic interference (EMI) is a significant challenge for low-field MRI systems operating without conventional Faraday-shielded rooms. Traditional EMI mitigation approaches include external shields, subject grounding via electrodes,…

Medical Physics · Physics 2026-05-26 Julia Pfitzer , Martin Uecker , Hermann Scharfetter

Ultra-low field magnetic resonance imaging(ULF-MRI) systems operating in open environments are highly susceptible to composite electromagnetic interference(EMI). Different imaging channels respond non-uniformly to EMI owing to their…

Signal Processing · Electrical Eng. & Systems 2025-09-09 Jiali He , Sheng Shen , Jiamin Wu , Xiaohan Kong , Yamei Dai , Liang Tan , Zheng Xu

A volume coil with squared slots-end ring was developed to attain improved sensitivity for imaging of rat's brain at 7 T. The principles of the high cavity resonator for the low-pass case and the law of Biot-Savart were used to derive a…

Medical Physics · Physics 2020-08-14 S. Solis-Najera , R. Martin , F. Vazquez , O. Marrufo , A. O. Rodriguez

Over the past years, rapid progress has been made on soft-matter electronics for wearable and implantable devices, for bioelectronics and optogenetics. Liquid Metal (LM) based electronics were especially popular, due to their long-term…

Medical Physics · Physics 2025-01-22 Denis Rocha , Pedro Lopes , Paulo Peixoto , Anibal de Almeida , Mahmoud Tavakoli

Magnetic Resonance Imaging (MRI) stands as a powerful modality in clinical diagnosis. However, it is known that MRI faces challenges such as long acquisition time and vulnerability to motion-induced artifacts. Despite the success of many…

Image and Video Processing · Electrical Eng. & Systems 2023-10-17 Lixuan Chen , Xuanyu Tian , Jiangjie Wu , Ruimin Feng , Guoyan Lao , Yuyao Zhang , Hongjiang Wei

Conventional MRI reconstruction methods treat images and coil sensitivities as discrete objects, leading to high memory demands and limited structural awareness that hamper effective regularization. These limitations hinder accurate…

Image and Video Processing · Electrical Eng. & Systems 2026-05-12 Ray Sheombarsing , Max van Riel , David Heesterbeek , Nico van den Berg , Alessandro Sbrizzi

The travelling-wave MRI approach is an alternative to overcome the B1 inhomogeneity at UHF MRI for human applications. More recently, this concept has been also used with animal MR imagers. We used a parallel-plate waveguide and a…

Medical Physics · Physics 2018-03-15 F. Vazquez , S. E. Solis-Najera , J. Lazovic , L. M. Zopf , R. Martin , L. Medina , O. Marrufo , A. O. Rodriguez

We looked for a biological analogy to developed an improved surface coil to acquire magnetic resonance images. Nature offers engineering solutions that can be exploited to improve the performance of devices, such as MRI RF coils. In this…

Medical Physics · Physics 2017-11-13 S. E. Solis-Najera , F. Vazquez , J. Lazovic , L. M. Zopf , R. Martin , L. Medina , O. Marrufo , A. O. Rodriguez

Using oscillating magnetic fields for indoor positioning is a robust way to resist dynamic environments. This work presents the hard- and software-related optimizations of an induced magnetic field positioning system. We describe a new coil…

Signal Processing · Electrical Eng. & Systems 2025-03-11 Sizhen Bian , Gerald Pirkl , Jingyuan Cheng , Paul Lukowicz

Magnetic Resonance Imaging (MRI) of hard biological tissues is challenging due to the fleeting lifetime and low strength of their response to resonant stimuli, especially at low magnetic fields. Consequently, the impact of MRI on some…

We recently published an approach named ROVir (Region-Optimized Virtual coils) that uses the beamforming capabilities of a multichannel magnetic resonance imaging (MRI) receiver array to achieve coil compression (reducing an original set of…

Signal Processing · Electrical Eng. & Systems 2023-07-24 Justin P. Haldar

Purpose: Low-field MRI systems operate at single MHz-range frequencies, where signal losses are primarily dominated by thermal noise from the radio-frequency (RF) receive coils. Achieving operation close to this limit is essential for…

Medical Physics · Physics 2026-03-09 Teresa Guallart-Naval , José M. Algarín , Joseba Alonso

Planar spirals offer a highly scalable geometry appropriate for wireless power transfer via strongly coupled inductive resonators. We numerically derive a set of geometric scale and material independent coupling terms, and analyze a simple…

Optics · Physics 2011-11-23 Avraham Klein , Nadav Katz

Nuclear magnetic resonance (NMR) spectroscopy is a powerful technique to study local magnetism in a variety of materials. However, the inherently low sensitivity of conventional inductively detected solid state NMR typically requires a…

Mesoscale and Nanoscale Physics · Physics 2025-12-16 Louis Beaudoin , Aimé Verrier , Youcef A. Bioud , Mathieu Massicotte , Bertrand Reulet , Jeffrey A. Quilliam

Magnetic Resonance Imaging (MRI) is a widely utilized diagnostic tool in clinical settings, but its application is limited by the relatively long acquisition time. As a result, fast MRI reconstruction has become a significant area of…

Image and Video Processing · Electrical Eng. & Systems 2025-06-09 Lixuan Rao , Xinlin Zhang , Yiman Huang , Tao Tan , Tong Tong

The growing use of wearable devices for activity tracking, healthcare, and haptics faces challenges due to the bulkiness and short lifespan of batteries. Integration of a textile-based wireless charging and readout system into everyday…

Human-Computer Interaction · Computer Science 2025-03-18 Ryo Takahashi , Yoshihiro Kawahara

Magnetic Resonance Imaging (MRI) is one of the most flexible and powerful medical imaging modalities. This flexibility does however come at a cost; MRI images acquired at different sites and with different parameters exhibit significant…

Transmitter arrays play a critical role in ultra high field Magnetic Resonance Imaging (MRI), especially given the advantages made possible via parallel transmission (pTx) techniques. One of the challenges in design and construction of…

A two-coil wearable system is proposed for wireless communication and powering between a transmitter coil in a necklace and a receiver coil in a smart contact lens, where the necklace is invisible in contrast to coils embedded in wearables…

Signal Processing · Electrical Eng. & Systems 2024-06-13 Sukriti Shaw , Mayukh Nath , Arunashish Datta , Shreyas Sen

This paper proposes an inductive coupled wireless power transfer system that analyses the relationship between induced voltage and distance of resonating inductance in a printed circuit spiral coils. The resonant frequency produced by the…

Signal Processing · Electrical Eng. & Systems 2018-10-25 Mohammad Haerinia , Ebrahim S. Afjei