Related papers: Plasma-Based Etching Approach for GEM Detector Mic…
Gas Electron Multiplier (GEM) detectors, typically featuring a standard pitch size of 140 $\mu$m and an inner hole diameter of 50 $\mu$m, are extensively utilized in high-energy physics experiments for tracking, triggering, and timing…
Gas detectors are one of the pillars of the research in fundamental physics. Since many years, a new concept of detectors, the Micro Pattern Gas Detectors, allows to overcome many of the problems of other types of commonly used detectors,…
Micro-pattern gas detectors, such as the Gas Electron Multiplier (GEM) and the Micromegas need narrow high density anode readout elements to achieve good spatial resolution. A high-density anode readout would require an unmanageable number…
We report on the results of a new, sealed, Gas Pixel Detector. The very compact design and the absence of the gas flow system, make this detector substantially ready for use as focal plane detector for future X-ray space telescopes. The…
A high-efficiency fast neutron detector prototype based on a triple Gas Electron Multiplier (GEM) detector, which coupled with a novel multi-layered High-Density PolyEthylene (HDPE) as a neutron-to-proton converter for improving the neutron…
The characterization of the electronic structure and chemical states of gases, solids, and liquids can be effectively performed using ambient pressure X-ray photoelectron spectroscopy (AP-XPS). However, the acquisition of electronic and…
An X-ray photoelectric polarimeter based on the Gas Pixel Detector has been proposed to be included in many upcoming space missions to fill the gap of about 30 years from the first (and to date only) positive measurement of polarized X-ray…
IXPE (Imaging X-ray Polarimetry Explorer) is a NASA Small Explorer mission -- in partnership with the Italian Space Agency (ASI) -- dedicated to X-ray polarimetry in the 2--8 keV energy band. The IXPE telescope comprises three grazing…
To solve the discharge of the standard Bulk Micromegas and GEM detector, the GEM-Micromegas detector was developed in Institute of High Energy Physics. Taking into account the advantages of the two detectors, one GEM foil was set as a…
In this work we characterized a X-ray position sensitive gaseous detector based in a triple stack of gas electron multipliers (GEM). The readout circuit is divided in 256 strips for each dimension and using a resistive chain interconnecting…
A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure…
The world's leading directional dark matter experiments currently all utilize low-pressure gas Time Projection Chamber (TPC) technologies. We discuss some of the challenges for this technology, for which balancing the goal of achieving the…
Imaging X-ray polarimetry with IXPE has demonstrated the scientific potential of the technique but also revealed the need for significant detector upgrades, particularly with the read-out ASIC that images photoelectron tracks and possibly…
The Gas Electron Multiplier (GEM) technology is based on thin polymer foils cladded with copper on both the sides with a regular matrix of holes. Due to the limited manufacturing capacity of CERN, these GEM foils are now commercially…
This document contains the pre-design of the beam diagnostics components Tracking Detectors for the Super-FRS. A GEM-TPC detector has been suggested as suitable tracking detector for the ion/fragment beams produced at the in-flight…
It is well known and has been shown that the gain performance of Gaseous Electron Multipliers (GEM) depends on the size of the holes. With an optical scanner it is possible to measure the dimensions of the holes, and to predict the…
In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron and the number of pixels is large (above 1000) it is virtually impossible to use the conventional PCB read-out approach to bring the signal charge from the…
The third generation of the Beijing Electron Spectrometer, BESIII, is an apparatus for high energy physics research. The hunting of new particles and the measurement of their properties or the research of rare processes are sought to…
This work aims to demonstrate that two arrays of Lumped Element Kinetic Inductance Detectors (LEKIDs), when employed in filled array configuration and separated by an external linear polarizer oriented at 45 degrees, can achieve the…
The development of micropixel gas detectors, capable to image tracks produced in a gas by photoelectrons, makes possible to perform polarimetry of X-ray celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a mission…