English
Related papers

Related papers: Dynamic Change of Amplitude for OCT Functional Ima…

200 papers

Based on high-throughput dark-field full-field optical coherence tomography, we designed and built an OCT system that can measure a variety of samples with different scattered light intensities, such as materials with multi-layer…

Optics · Physics 2024-01-30 Youlong Fan , Qingye Hu , Zhongping Wang , Xiantao Wei , Zengming Zhang

Optical coherence tomography offers astounding opportunities to image the complex structure of living tissue, but lacks functional information. We present dynamic full-field optical coherence tomography to image living human induced…

Clinical tracking systems are popular but typically require specific tracking markers. During the last years, scanning speed of optical coherence tomography (OCT) has increased to A-scan rates above 1 MHz allowing to acquire volume scans of…

Medical Physics · Physics 2019-01-15 Matthias Schlüter , Christoph Otte , Thore Saathoff , Nils Gessert , Alexander Schlaefer

Transmission optical coherence tomography (OCT) enables analysis of biological specimens in vitro through detection of forward scattered light. Up to now, transmission OCT was considered as a technique that cannot directly retrieve…

Optics · Physics 2024-05-24 Wojciech Krauze , Martyna Mazur , Arkadiusz Kuś

Optical diffraction tomography (ODT) is a three-dimensional (3D) label-free imaging technique. The 3D refractive index distribution of a sample can be reconstructed from multiple two-dimensional optical field images via ODT. Herein, we…

Optics · Physics 2021-02-03 Chansuk Park , Kyeoreh Lee , Yoonseok Baek , Yongkeun Park

Optical coherence tomography angiography (OCTA) is a non-invasive imaging technique widely used to study vascular structures and micro-circulation dynamics in the retina and choroid. OCTA has been widely used in clinics for diagnosing…

Image and Video Processing · Electrical Eng. & Systems 2025-08-26 Kejie Chen , Guanbing Gao , Xiaochun Yang , Wenbo Wang , Jing Na

The measurement of three-dimensional (3D) images and the analysis of subcellular organelles are crucial for the study of the pathophysiology of cells and tissues. Optical diffraction tomography (ODT) facilitates label-free and quantitative…

Image and Video Processing · Electrical Eng. & Systems 2019-10-08 Taean Chang , Seungwoo Shin , Moosung Lee , YongKeun Park

Optoacoustic tomography (OAT), also known as photoacoustic tomography, is a rapidly emerging hybrid imaging technique that possesses great potential for a wide range of biomedical imaging applications. In OAT, a laser is employed to…

Medical Physics · Physics 2016-12-21 Yang Lou , Kun Wang , Alexander. A. Oraevsky , Mark. A. Anastasio

Full-field optical coherence tomography (FF-OCT) offers label-free, high-resolution imaging of biological samples but remains limited by slow acquisition due to piezoelectric mirror modulation. We present a continuous-scanning FF-OCT method…

Optics · Physics 2025-09-11 Charlie Kersuzan , Anirban Jana , Amaury Badon

Optical coherence tomography (OCT) has proven to be a powerful technique for studying tissue morphology in ophthalmology, cardiology, and endomicroscopy. Its performance is limited by the fundamental trade-off between the imaging…

Optics · Physics 2008-02-27 Keisuke Goda , Daniel R. Solli , Bahram Jalali

Modern optical coherence tomography (OCT) devices provide volumetric images with micrometer-scale spatial resolution and a temporal resolution beyond video rate. In this work, we analyze an OCT-based prototypical tracking system which…

Image and Video Processing · Electrical Eng. & Systems 2020-01-22 Matthias Schlüter , Lukas Glandorf , Johanna Sprenger , Martin Gromniak , Maximilian Neidhardt , Thore Saathoff , Alexander Schlaefer

Optical Coherence Tomography (OCT) is a key 3D imaging technology that provides micron scale depth resolution for bio-imaging. This resolution substantially surpasses what it typically achieved in Light Detection and Ranging (LiDAR) which…

Optics · Physics 2022-07-27 Robbie Murray , Ashley Lyons

Optical diffraction tomography (ODT) has emerged as an important label-free tool in biomedicine to measure the three-dimensional (3D) structure of a biological sample. In this paper, we describe ODT using second-harmonic generation (SHG)…

Optics · Physics 2024-05-21 Amirhossein Saba , Carlo Gigli , Ye Pu , Demetri Psaltis

Optical coherence tomography (OCT) and confocal microscopy are pivotal in retinal imaging, offering distinct advantages and limitations. In vivo OCT offers rapid, non-invasive imaging but can suffer from clarity issues and motion artifacts,…

Image and Video Processing · Electrical Eng. & Systems 2024-12-18 Xin Tian , Nantheera Anantrasirichai , Lindsay Nicholson , Alin Achim

Optical coherence tomography (OCT) is a non-invasive volumetric imaging modality with high spatial and temporal resolution. For imaging larger tissue structures, OCT probes need to be moved to scan the respective area. For handheld…

Computer Vision and Pattern Recognition · Computer Science 2026-03-24 Suresh Guttikonda , Maximilian Neidhardt , Vidas Raudonis , Alexander Schlaefer

Optical coherence tomography (OCT) is a powerful technology for rapid volumetric imaging in biomedicine. The bright field imaging approach of conventional OCT systems is based on the detection of directly backscattered light, thereby…

A new formulation of lateral imaging process of point-scanning optical coherence tomography (OCT) and a new differential contrast method designed by using this formulation are presented. The formulation is based on a mathematical sample…

Since the introduction of optical coherence tomography (OCT), it has been possible to study the complex 3D morphological changes of the optic nerve head (ONH) tissues that occur along with the progression of glaucoma. Although several deep…

Optical Coherence Tomography (OCT) is an emerging medical imaging modality for luminal organ diagnosis. The non-constant rotation speed of optical components in the OCT catheter tip causes rotational distortion in OCT volumetric scanning.…

Optical Coherence Tomography (OCT) was originally conceived as a volumetric imaging method. Quickly, OCT images went beyond structural data and started to provide functional information about an object enabling for example visualization of…