English
Related papers

Related papers: Performance of the most recent Microchannel-Plate …

200 papers

The PANDA experiment at the FAIR facility at GSI will study hadron physics using a high intensity antiproton beam of up to 15 GeV/c momentum to perform high precision spectroscopy. Two DIRC detectors with their image planes residing in an…

The DIRC technology (Detection of Internally Reflected Cherenkov light) offers an excellent possibility to minimize the form factor of Cherenkov detectors in hermetic high energy detectors. The PANDA experiment at FAIR in Germany will…

The PANDA experiment at the future Facility for Antiproton and Ion Reasearch (FAIR) will address fundamental questions of hadron physics with unprecedented precision. To reach this goal excellent Particle Identification (PID) is essential…

Instrumentation and Detectors · Physics 2019-01-15 J. Schwiening

The PANDA detector at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR) addresses fundamental questions of hadron physics. An excellent hadronic particle identification (PID) will be accomplished by two…

The PANDA experiment at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR), Darmstadt, Germany, will address fundamental questions of hadron physics using $\bar{p}p$ annihilations. Excellent Particle…

Excellent particle identification (PID) will be essential for the PANDA experiment at FAIR. The Barrel DIRC will separate kaons and pions with at least 3 s.d. for momenta up to 3.5 GeV/c and polar angles between 22 and 140 deg. After…

A systematic investigation of Planacon MCP-PMTs was performed using 64 XP85002/FIT-Q photosensors. These devices are equipped with microchannel plates of reduced resistance. Results of a study of their gain stability over time and…

In this paper, we present our approach to systematically measure numerous performance parameters of MCP-PMTs. The experimental setups, the analyses and selected results are discussed. Although the techniques used may be different in other…

Instrumentation and Detectors · Physics 2024-07-08 A. Lehmann , M. Böhm , M. Götz , K. Gumbert , S. Krauss , D. Miehling , M. Pfaffinger

The innovative Barrel DIRC (Detection of Internally Reflected Cherenkov light) counter will provide hadronic particle identification (PID) in the central region of the PANDA experiment at the new Facility for Antiproton and Ion Research…

The PANDA experiment at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR) near GSI, Darmstadt, Germany will address fundamental questions of hadron physics. Excellent Particle Identification (PID) over…

Instrumentation and Detectors · Physics 2018-03-29 J. Schwiening

Silicon photomultipliers are very versatile photo detectors due to their high photon detection efficiency, fast response, single photon counting capability, high amplification, and their insensitivity to magnetic fields. At our institute we…

Nuclear Experiment · Physics 2015-05-18 G. S. M. Ahmed , P. Bühler , J. Marton , K. Suzuki

Multi Micro-Channel-Plate Photomultiplier tubes (MCP-PMT) with High Collection Efficiency (Hi-CE) MCPs are developed and characterised. With these Hi-CE MCPs more than 90% of photoelectrons emitted from the photocathode can be detected;…

Instrumentation and Detectors · Physics 2018-03-14 D. A. Orlov , T. Ruardij , S. Duarte Pinto , R. Glazenborg , E. Kernen

Jinping Neutrino Experiment plans to deploy a new type of 8-inch MCP-PMT with high photon detection efficiency for MeV-scale neutrino measurements. This work studies the performance of the MCP-PMTs, including the photon detection…

High Energy Physics - Experiment · Physics 2023-07-17 Aiqiang Zhang , Benda Xu , Jun Weng , Huiyou Chen , Wenhui Shao , Tong Xu , Ling Ren , Sen Qian , Zhe Wang , Shaomin Chen

Improving the coincidence time resolution (CTR) of time-of-flight positron emission tomography (TOF-PET) systems to achieve a higher signal-to-noise ratio (SNR) gain or even direct positron emission imaging (dPEI) is of paramount importance…

The 64-channel Multianode Photo Multiplier (MaPMT) has been evaluated as a candidate for the LHCb Ring Imaging Cherenkov (RICH) photo detectors. We present result from data taken with a 3x3 array of closely packed MaPMTs mounted onto the…

High Energy Physics - Experiment · Physics 2009-11-10 F. Muheim

The peak photon detection efficiency (PDE) of silicon photomultipliers (SiPMs) can be as good or better than the PDE of photomultiplier tubes (PMTs). There are experiments where the signal is measured in the presence of a strong, steady…

Instrumentation and Methods for Astrophysics · Physics 2024-04-23 A. Hahn , R. Mirzoyan , A. Dettlaff , D. Fink , D. Mazin , M. Teshima

The key component of the future PANDA experiment at FAIR is a fixed-target detector for collisions of antiprotons with a proton target up to a beam momentum of 15 GeV/c and is designed to address a large number of open questions in the…

Since the early days of experimental particle physics photomultipliers (PMTs) have played an important role in the detector design. Thanks to their capability of fast photon counting, PMTs are extensively used in the new-generation of…

Instrumentation and Detectors · Physics 2016-08-24 C. Bozza , T. Chiarusi , M. Costa , F. Di Capua , V. Kulikovskiy , R. Mele , P. Migliozzi , C. M. Mollo , C. Pellegrino , G. Riccobene , D. Vivolo

A novel photodetector based on a MCP-PMT vacuum tube with encapsulated CMOS ASIC has been tested at the CERN SPS high energy hadron beam, allowing single photon Cherenkov detection operating at 10$^4$ gain and with timing resolution of…

The PANDA experiment is one of the four large experiments being built at FAIR in Darmstadt. It will use a cooled antiproton beam on a fixed target within the momentum range of 1.5 to 15 GeV/c to address questions of strong QCD, where the…

‹ Prev 1 2 3 10 Next ›