Related papers: Parameterised Geant4 simulation for total body PET…
Parametric imaging is a compartmental approach that processes nuclear imaging data to estimate the spatial distribution of the kinetic parameters governing tracer flow. The present paper proposes a novel and efficient computational method…
Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms…
We present {\gamma} spectroscopy validation measurements for the Geant4 radioactive decay simulation for a selected range of isotopes using a simple experimental setup. Using these results we point out problems in the decay simulation and…
Geant4-based simulations of the energy deposited by electrons in various materials are quantitatively compared to high precision calorimetric measurements taken at Sandia Laboratories. The experimental data concern electron beams of energy…
Positron Emission Tomography (PET) is an imaging method that can assess physiological function rather than structural disturbances by measuring cerebral perfusion or glucose consumption. However, this imaging technique relies on injection…
Positron Emission Tomography (PET) image reconstruction is inherently challenged by Poisson noise and physical degradation factors, which are further exacerbated in limited-angle acquisitions. While deep learning methods demonstrate…
Positron Emission Tomography (PET) enables functional imaging of deep brain structures, but the bulk and weight of current systems preclude their use during many natural human activities, such as locomotion. The proposed long-term solution…
The program Simourg (Simulator of Usually Requested Geometries) is based on the Geant4 toolkit and created for Monte Carlo simulation of gamma-ray spectrometric nuclear detectors with a simple axial symmetric geometry, which is typical for…
Geant4 is a tool kit developed by a collaboration of physicists and computer professionals in the High Energy Physics field for simulation of the passage of particles through matter. The motivation for the development of the Beam Tools is…
Tumor lesion segmentation is one of the most important tasks in medical image analysis. In clinical practice, Fluorodeoxyglucose Positron-Emission Tomography~(FDG-PET) is a widely used technique to identify and quantify metabolically active…
The low cost and high resolution gas-based Multi-gap Resistive Plate Chamber (MRPC) opens a new possibility to find an efficient alternative detector for Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the…
KM2A is one of the main sub-arrays of LHAASO, working on gamma ray astronomy and cosmic ray physics at energies above 10 TeV. Detector simulation is the important foundation for estimating detector performance and data analysis. It is a big…
The construction of modern detectors used in high-energy physics experiments is typically guided by modeling with the Geant4 toolkit to evaluate detector performance in terms of geometrical acceptance and detection efficiency. Several…
The Generic Geant4 Simulation (GGS) is a package designed to speed-up the realization and deployment of Monte Carlo simulation software based on Geant4, for small- and medium-sized high-energy experiments. For many common use cases, the…
Positron Emission Tomography (PET) scanners are usually designed with the goal to obtain the best compromise between sensitivity, resolution, field-of-view size, and cost. Therefore, it is difficult to improve the resolution of a PET…
To improve the quality of cancer treatment with protons, a translation of X-ray Computed Tomography (CT) images into a map of the proton stopping powers needs to be more accurate. Proton stopping powers determined from CT images have…
A NEMA performance evaluation was conducted on the new General Electric (GE) digital Omni Legend PET-CT system with 32-cm extended field-of-view. This study marks the introduction of the first-ever commercially available clinical digital…
We compare existing segmented plastic antineutrino detectors with our new geometrically improved design for antineutrino detection and light collection efficiency. The purpose of this study is to determine the most suitable design style for…
The imaging performance of a high-resolution preclinical microPET system employing liquid xenon as the gamma ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection…
The present paper proposes a novel computational method for parametric imaging of nuclear medicine data. The mathematical procedure is general enough to work for compartmental models of diverse complexity and is effective in the…