This paper investigates power swing characteristics of grid-forming voltage source converter (GFM-VSC) systems considering the current limitation mode in both non-inertial and inertial GFM-VSC systems. Following grid faults, non-inertial…

Systems and Control · Electrical Eng. & Systems 2025-04-17 Yongxin Xiong , Heng Wu , Yifei Li , Xiongfei Wang

Transients of a grid-synchronized voltage source converter (VSC) are closely related to over- currents and voltages occurred under large disturbances (e.g. a grid fault). Previous analysis in evaluating these transients usually neglect the…

Systems and Control · Computer Science 2018-07-02 Chen Zhang , Marta Molinas , Xu Cai , Atle Rygg

Differing from synchronous generators, there are lack of physical laws governing the synchronization dynamics of voltage-source converters (VSCs). The widely used phase-locked loop (PLL) plays a critical role in maintaining the synchronism…

Systems and Control · Computer Science 2019-09-04 Heng Wu , Xiongfei Wang

Integrating grid-forming converters (GFMCs) into grid-following converter (GFLC)-dominated power systems enhances the grid strength, but GFMCs' current-limiting characteristic triggers dynamic switching between constant voltage control…

Systems and Control · Electrical Eng. & Systems 2026-04-22 Bingfang Li , Songhao Yang , Pu Cheng , Zhiguo Hao

The renewable energy is connected to the power grid through power electronic converters, which are lack of make the inertia of synchronous generator/machine (SM) be lost. The increasing penetration of renewable energy in power system…

Systems and Control · Electrical Eng. & Systems 2020-09-15 Yuan Gao , Hai-Peng Ren , Jie Li

Grid-forming (GFM) inverter-based resources (IBRs) can emulate the external characteristics of synchronous generators (SGs) through appropriate control loop design. However, in systems with GFM IBRs, the apparent impedance trajectory under…

Systems and Control · Electrical Eng. & Systems 2025-03-18 Yanshu Niu , Zhe Yang , Bikash C. Pal

Low-frequency oscillations (LFOs) present a significant challenge to the stability and reliability of power systems, especially in grids with a high penetration of renewable energy sources. Traditional grid-following (GFL) inverters have…

Systems and Control · Electrical Eng. & Systems 2025-06-02 Tamojit Chakraborty , Anamitra Pal , Sam Maleki

In scenarios where synchronous generators (SGs) and grid-following renewable energy sources (GFLR) are co-located, existing research, which mainly focuses on the first-swing stability of SGs, often overlooks ongoing dynamic interactions…

Systems and Control · Electrical Eng. & Systems 2026-03-27 Bingfang Li , Songhao Yang , Guosong Wang , Yiwen Hu , Xu Zhang , Zhiguo Hao , Dongxu Chang , Baohui Zhang

Fluctuations in phase angle and frequency under large disturbances can lead to loss of synchronism (LOS) in grid-following (GFL) converters. The power angle and frequency of synchronous generators (SGs) correspond to rotor position and…

Systems and Control · Electrical Eng. & Systems 2025-09-03 Fangyuan Sun , Ruisheng Diao , Ruiyuan Zeng , Junjie Li , Wangqianyun Tang

Under asymmetrical faults, analyzing the transient stability of grid-forming voltage-source converters (GFM-VSCs) becomes essential because their behavior fundamentally differs from that under symmetrical faults. When current limiting is…

Systems and Control · Electrical Eng. & Systems 2025-11-20 Seongyeon Kim , Ki-Hyun Kim , Shenghui Cui , Jae-Jung Jung

The MMC-HVDC connected offshore wind farms (OWFs) could suffer short circuit fault (SCF), whereas their transient stability is not well analysed. In this paper, the mechanism of the loss of synchronization (LOS) of this system is analysed…

Systems and Control · Electrical Eng. & Systems 2021-10-26 Yu Zhang , Chen Zhang , Renxin Yang , Jing Lyu , Li Liu , Xu Cai

The oscillation phenomena associated with the control of voltage source converters (VSCs) are widely concerning, and locating the source of these oscillations is crucial to suppressing them; therefore, this paper presents a locating scheme,…

Systems and Control · Electrical Eng. & Systems 2023-02-20 Zetian Zheng , Shaowei Huang , Jun Yan , Qiangsheng Bu , Chen Shen , Mingzhong Zheng , Ye Liu

The power synchronization control (PSC) has been increasingly used with voltage-source converters (VSCs) connected to the weak ac grid. This paper presents an in-depth analysis on the transient stability of the PSC-VSC by means of the phase…

Systems and Control · Computer Science 2018-10-30 Heng Wu , Xiongfei Wang

We consider a grid-connected voltage source converter (VSC) and address the problem of estimating the grid angle and frequency, information that is essential for an appropriate operation of the converter. We design phase-locked loop (PLL)…

Systems and Control · Electrical Eng. & Systems 2022-07-19 Daniele Zonetti , Oriol Gomis-Bellmunt , Eduardo Prieto-Araujo , Marc Cheah-Mane

This letter presents a comprehensive analysis of the stability phenomenon related to the ability of generators to remain in synchronism when subjected to small or large disturbances, in power systems with both synchronous machines and…

Systems and Control · Electrical Eng. & Systems 2026-05-20 Régulo E. Ávila-Martínez , Javier Renedo , Luis Rouco , Aurelio Garcia-Cerrada , Lukas Sigrist

This paper presents a novel strategy for the synchronization of grid-following Voltage Source Converters (VSCs) in power systems with low rotational inertia. The proposed synchronization unit is based on emulating the physical properties of…

Systems and Control · Electrical Eng. & Systems 2022-06-30 Ognjen Stanojev , Uros Markovic , Petros Aristidou , Gabriela Hug

Phase-locked loops (PLL), Costas loops and other synchronizing circuits are featured by the presence of a nonlinear phase detector, described by a periodic nonlinearity. In general, nonlinearities can cause complex behavior of the system…

Systems and Control · Computer Science 2015-08-21 Vera Smirnova , Anton Proskurnikov , Natalia V. Utina

Grid-forming voltage source converters (GFM-VSCs) play a crucial role in the stability of power systems with large amounts of converter-based generation. Transient stability (angle stability under large disturbances) is a critical limiting…

Systems and Control · Electrical Eng. & Systems 2026-03-24 Régulo E. Ávila-Martínez , Luis Rouco , Javier Renedo , Lukas Sigrist , Aurelio Garcia-Cerrada

The converter control functions to provide the capabilities similar to synchronous generators are referred to as grid forming converters (GFC). Identical to a synchronous machine, a grid forming converter is expected to behave as a voltage…

Systems and Control · Electrical Eng. & Systems 2021-06-21 Kanakesh Vatta Kkuni , Sibin Mohan , Guangya Yang , Wilsun Xu

Power dissipation in sequential circuits is due to increased toggling count of Circuit under Test, which depends upon test vectors applied. If successive test vectors sequences have more toggling nature then it is sure that toggling rate of…

Neural and Evolutionary Computing · Computer Science 2011-11-08 Balwnder Singh , Sukhleen Bindra Narang , Arun Khosla