English
Related papers

Related papers: Cryogenic resonant amplifier for electron-on-heliu…

200 papers

Accurate detection of quantum states is a vital step in the development of quantum computing. Image-charge detection of quantum states of electrons on liquid helium can potentially be used for the readout of a single-electron qubit;…

Quantum Physics · Physics 2021-01-12 Asem Elarabi , Erika Kawakami , Denis Konstantinov

To search for dark matter candidates with masses below $\mathcal{O}$(MeV), the SPLENDOR (Search for Particles of Light dark mattEr with Narrow-gap semiconDuctORs) experiment is developing novel narrow-bandgap semiconductors with electronic…

The SPLENDOR Collaboration studies novel narrow-gap semiconductors and engineered a substrate agnostic detector platform to achieve $\mathcal{O}$(meV) energy sensitivity designed for low mass dark matter searches. This was achieved using…

Instrumentation and Detectors · Physics 2025-10-03 Jadyn Anczarski , Owen Andrews , Taylor Aralis , Caleb Fink , Noah Kurinsky , Arran Phipps , Aditi Pradeep , Betty A. Young

We employ a cryogenic High Electron Mobility Transistor (HEMT) amplifier to increase the bandwidth of a charge detection setup with a quantum point contact (QPC) charge sensor. The HEMT is operating at 1K and the circuit has a bandwidth of…

Mesoscale and Nanoscale Physics · Physics 2009-11-13 I. T. Vink , T. Nooitgedagt , R. N. Schouten , W. Wegscheider , L. M. K. Vandersypen

The photon detection system of the first far detector (FD1-HD) of the DUNE experiment will detect scintillation photons produced by particle interactions in a kiloton-scale liquid Argon time projection chamber. The photon detectors of…

We show that a cryogenic amplifier composed of a homemade GaAs high-electron-mobility transistor (HEMT) is suitable for current-noise measurements in a mesoscopic device at dilution-refrigerator temperatures. The lower noise characteristics…

Mesoscale and Nanoscale Physics · Physics 2021-02-25 Sanghyun Lee , Masayuki Hashisaka , Takafumi Akiho , Kensuke Kobayashi , Koji Muraki

Fault-tolerant spin-based quantum computers will require fast and accurate qubit readout. This can be achieved using radio-frequency reflectometry given sufficient sensitivity to the change in quantum capacitance associated with the qubit…

Electrons trapped on the surface of superfluid helium have been thought of as a useful resource for quantum computing. Such electrons show long coherence of their surface-bound (Rydberg) states combined with their easy electrostatic…

Mesoscale and Nanoscale Physics · Physics 2025-01-07 Mikhail Belianchikov , Natalia Morais , Denis Konstantinov

This paper presents a low noise amplifier for large arrays of silicon photomultipliers (SiPMs) operated in cryogenic environments, especially liquid argon (87 K) and liquid nitrogen (77 K). The goal is for one amplifier to read out a total…

Instrumentation and Detectors · Physics 2020-01-15 P. Carniti , A. Falcone , C. Gotti , A. Lucchini , G. Pessina , S. Riboldi , F. Terranova

The quest to enhance the sensitivity of electron spin resonance (ESR) is an ongoing challenge. One potential strategy involves increasing the frequency, for instance, moving from Q-band (approximately 35 GHz) to W-band (approximately 94…

Chemical Physics · Physics 2024-11-22 Moamen Jbara , Oleg Zgadzai , Wolfgang Harneit , Aharon Blank

We propose a new type of cryogenic current amplifiers, in which low-frequency power spectrum of current can be measured through a measurement of microwave response of a superconducting resonant circuit shunted by a series array of Josephson…

Instrumentation and Detectors · Physics 2015-08-14 Yuma Okazaki , Nobu-hisa Kaneko

The image-charge detection provides a new direct method for the detection of the Rydberg transition in electrons trapped on the surface of liquid helium. The interest in this method is motivated by the possibility to accomplish the spin…

Mesoscale and Nanoscale Physics · Physics 2022-07-11 Shan Zou , Denis Konstantinov

We propose a Rydberg-atom-based single-photon detector for signal readout in dark matter haloscope experiments between 40 ${\mu}$eV and 200 ${\mu}$eV (10 GHz and 50 GHz). At these frequencies, standard haloscope readout using linear…

We have designed and characterized a cryogenic amplifier for use in $^3$He NMR spectrometry. The amplifier, with a power consumption of $\sim 2.5$ mW, works at temperatures down to 4~K. It has a hi-impedance input for measuring a signal…

Instrumentation and Detectors · Physics 2019-04-24 V. V. Zavjalov , A. M. Savin , P. J. Hakonen

In this study, we present the design and analysis of a Low Noise Amplifier tailored specifically for quantum applications. We selected the HEMT for its unique noise reduction properties, crucial for quantum engineering. The main goal is to…

Quantum Physics · Physics 2024-08-16 Ahmad Salmanogli

We present a cryogenic microwave noise source with a characteristic impedance of 50 $\Omega$, which can be installed in a coaxial line of a cryostat. The bath temperature of the noise source is continuously variable between 0.1 K and 5 K…

We examine a silicon-germanium heterojunction bipolar transistor (HBT) for cryogenic pre-amplification of a single electron transistor (SET). The SET current modulates the base current of the HBT directly. The HBT-SET circuit is immersed in…

Mesoscale and Nanoscale Physics · Physics 2015-09-29 M. J. Curry , T. D. England , N. C. Bishop , G. Ten-Eyck , J. R. Wendt , T. Pluym , M. P. Lilly , S. M. Carr , M. S. Carroll

Large-scale superconducting quantum computers require massive numbers of high-performance cryogenic low-noise amplifiers (cryo-LNA) for qubit readout. Here we present a C-Band monolithic microwave integrated circuit (MMIC) cryo-LNA for this…

Large-scale cryogenic quantum systems are constrained by an input-output bottleneck between room-temperature electronics and millikelvin stages, particularly in superconducting qubit platforms. This bottleneck is most acute for output…

A superconducting flux qubit is inductively coupled to a Superconducting QUantum Interference Device (SQUID) magnetometer, capacitively shunted to form a 1.294-GHz resonator. The qubit-state-dependent resonator frequency is weakly probed…

Superconductivity · Physics 2012-03-07 J. E. Johnson , E. M. Hoskinson , C. Macklin , D. H. Slichter , I. Siddiqi , John Clarke
‹ Prev 1 2 3 10 Next ›