English
Related papers

Related papers: Monitoring TES Loop Gain in Frequency Multiplexed …

200 papers

Time-Division Multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in…

We demonstrate strong negative electrothermal feedback accelerating and linearizing the response of a thermal kinetic inductance detector (TKID). TKIDs are a proposed highly multiplexable replacement to transition-edge sensors and measure…

Frequency domain multiplexing (FDM) is the baseline readout system for the X-ray Integral Field Unit (X-IFU) on board the Athena mission. Under the FDM scheme, TESs are coupled to a passive LC filter and biased with alternating current (AC…

We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum…

Detectors based on pixels with timing capabilities are gaining increasing importance in the last years. Next-to-come high-energy physics experiments at colliders require the use of time information in tracking, due to the expected levels of…

Instrumentation and Detectors · Physics 2023-01-27 Gian Matteo Cossu , Adriano Lai

Understanding the magnetic field sensitivity of Transition Edge Sensors (TESs) is vital in optimising the configuration of any magnetic shielding as well as the design of the TESs themselves. An experimental system has been developed to…

Instrumentation and Methods for Astrophysics · Physics 2023-10-03 R. C. Harwin , D. J. Goldie , C. N. Thomas , S. Withington

Transition-edge sensors (TESs) are capable of highly accurate single particle energy measurement. TESs have been used for a wide range of photon detection applications, particularly in astronomy, but very little consideration has been given…

Instrumentation and Detectors · Physics 2023-05-11 K. M. Patel , S. Withington , C. N. Thomas , A. G. Shard , D. J. Goldie

The Advanced ACTPol (AdvACT) upgrade to the Atacama Cosmology Telescope (ACT) features arrays of aluminum manganese transition-edge sensors (TESes) optimized for ground-based observations of the Cosmic Microwave Background (CMB). Array…

It has been recently demonstrated that superconducting transition edge sensors (TESs) behave as weak-links due to longitudinally induced superconductivity from the leads with higher Tc. In this work we study the implication of this…

Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a resonant…

A high accuracy and high sensitivity system architecture is proposed for the read-out circuit of electrical impedance tomography system-on-chip. The switched ratiometric technique is applied in the proposed architecture. The proposed system…

Medical Physics · Physics 2018-10-24 Hui Li , Boxiao Liu , Yongfu Li , Guoxing Wang , Yong Lian

Thermal Energy Storage (TES) devices, which leverage the constant-temperature thermal capacity of the latent heat of a Phase Change Material (PCM), provide benefits to a variety of thermal management systems by decoupling the absorption and…

Systems and Control · Electrical Eng. & Systems 2024-03-01 Trent J. Sakakini , Justin P. Koeln

This paper presents and evaluates a novel method for generating power losses on transistors avoiding high currents. These could heat up the circuit tracks, affecting the accurate thermal modeling of the system. The proposed procedure is…

Systems and Control · Electrical Eng. & Systems 2023-09-05 Jose Miguel Sanz-Alcaine , Francisco Jose Perez-Cebolla , Carlos Bernal-Ruiz , Asier Arruti , Iosu Aizpuru , Juan Sanchez

We study in this paper the problem of iterative feedback gains tuning for a class of nonlinear systems. We consider Input-Output linearizable nonlinear systems with additive uncertainties. We first design a nominal Input-Output…

Systems and Control · Computer Science 2016-11-15 Mouhacine Benosman

Transition Edge Sensor (TES) bolometers are a well-established technology with a strong track record in experimental cosmology, making them ideal for current and future radio astronomy instruments. The Tomographic Ionized-carbon Mapping…

Instrumentation and Methods for Astrophysics · Physics 2025-10-06 Victoria L. Butler , James J. Bock , Dongwoo T. Chung , Abigail T. Crites , King Lau , Ian Lowe , Dan P. Marrone , Evan C. Mayer , Benjamin J. Vaughan , Michael Zemcov

We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m squared, AuBi…

We present herein gain stabilization studies of SiPMs using a climate chamber at CERN. We present results for four detectors not tested before, three from Hamamatsu and one from KETEK. Two of the Hamamatsu SiPMs are novel sensors with…

Instrumentation and Detectors · Physics 2016-03-02 Gerald Eigen , Are Træet , Justas Zalieckas , Jaroslav Cvach , Jiri Kvasnicka , Ivo Polak

A superconducting quantum interference device (SQUID), functioning as a nonlinear response device, typically requires the incorporation of a flux-locked loop (FLL) circuit to facilitate linear amplification of the current signal transmitted…

Instrumentation and Methods for Astrophysics · Physics 2026-03-02 Nan Li , Xiang-xiang Ren , Le-peng Li , Meng-jie Song , Hao-yu Li , Shi-bo Shu , Ya-qiong Li , Yong-jie Zhang , Xu-fang Li , Yu-dong Gu , Cong-zhan Liu , Hai-feng Li , He Gao , Zheng-wei Li

We have measured and characterized the thermal crosstalk in two different arrays of transition-edge sensor (TES) X-ray micro-calorimeters with frequency-domain multiplexing (FDM) readout. The TES arrays are fabricated at SRON and are a…

We have designed a system to stabilize the gain of a submillimeter heterodyne receiver against thermal fluctuations of the mixing element. In the most sensitive heterodyne receivers, the mixer is usually cooled to 4 K using a closed-cycle…