English
Related papers

Related papers: Mechanical Artifacts in Optical Projection Tomogra…

200 papers

Computed Tomography is a powerful imaging technique that allows non-destructive visualization of the interior of physical objects in different scientific areas. In traditional reconstruction techniques the object of interest is mostly…

Image and Video Processing · Electrical Eng. & Systems 2019-05-03 Koen Ruymbeek , Wim Vanroose

Two-photon photopolymerization (TPP) has recently become a popular method for the fabrication of three-dimensional (3D) micro- and nanostructures. The reproduction fidelity of the designed micro- and nanostructures is influenced by…

Optics · Physics 2022-07-12 Yanping He , Qi Shao , Shih-chi Chen , Renjie Zhou

Optical diffraction tomography (ODT) is an interferometric microscopy technique capable of measuring 3-D refractive index (RI) distribution of transparent samples. Multiple 2-D holograms of a sample illuminated with various angles are…

Computed tomography is a method for synthesizing volumetric or cross-sectional images of an object from a collection of projections. Popular reconstruction methods for computed tomography are based on idealized models and assumptions that…

Numerical Analysis · Mathematics 2022-03-03 Frederik H. Pedersen , Jakob S. Jørgensen , Martin S. Andersen

Computed Tomography (CT) using synchrotron radiation is a powerful technique that, compared to lab-CT techniques, boosts high spatial and temporal resolution while also providing access to a range of contrast-formation mechanisms. The…

Image and Video Processing · Electrical Eng. & Systems 2025-01-20 Jiayang Shi , Daniel M. Pelt , K. Joost Batenburg

Optical coherence tomography (OCT) is a widely used imaging technique in the micrometer regime, which gained accelerating interest in medical imaging in the last twenty years. In up-to-date OCT literature [5,6] certain simplifying…

Medical Physics · Physics 2024-02-23 Leopold Veselka , Lisa Krainz , Leonidas Mindrinos , Wolfgang Drexler , Peter Elbau

Optical diffraction tomography (ODT) is a tomographic technique that can be used to measure the three-dimensional (3D) refractive index distribution within living cells without the requirement of any marker. In principle, ODT can be…

Quantitative Methods · Quantitative Biology 2018-01-03 Paul Müller , Mirjam Schürmann , Chii J. Chan , Jochen Guck

Optical Coherence Tomography (OCT) is one of the most emerging imaging modalities that has been used widely in the field of biomedical imaging. From its emergence in 1990's, plenty of hardware and software improvements have been made. Its…

Computer Vision and Pattern Recognition · Computer Science 2014-11-18 Ahmadreza Baghaie , Roshan M. D'souza , Zeyun Yu

Significant progress in many classes of materials could be made with the availability of experimentally-derived large datasets composed of atomic identities and three-dimensional coordinates. Methods for visualizing the local atomic…

Optical Coherence Tomography (OCT) is one of the most important retinal imaging technique. However, involuntary motion artifacts still pose a major challenge in OCT imaging that compromises the quality of downstream analysis, such as…

Image and Video Processing · Electrical Eng. & Systems 2023-05-31 Yiqian Wang , Alexandra Warter , Melina Cavichini , Varsha Alex , Dirk-Uwe G. Bartsch , William R. Freeman , Truong Q. Nguyen , Cheolhong An

Spectral domain optical coherence tomography (OCT) offers high resolution multidimensional imaging, but generally suffers from defocussing, intensity falloff and shot noise, causing artifacts and image degradation along the imaging depth.…

Image and Video Processing · Electrical Eng. & Systems 2021-08-04 Jonathan H. Mason , Yvonne Reinwald , Ying Yang , Sarah Waters , Alicia El Haj , Pierre O. Bagnaninchi

Optical diffraction tomography (ODT) is a three-dimensional (3D) quantitative phase imaging technique, which enables the reconstruction of the 3D refractive index (RI) distribution of a transparent sample. Due to its fast, non-invasive, and…

Optics · Physics 2018-11-14 Chansuk Park , Seungwoo Shin , Yongkeun Park

Purpose: Optoacoustic tomography (OAT) is inherently a three-dimensional (3D) inverse problem. However, most studies of OAT image reconstruction still employ two-dimensional (2D) imaging models. One important reason is because 3D image…

Medical Physics · Physics 2013-04-09 Kun Wang , Chao Huang , Yu-Jiun Kao , Cheng-Ying Chou , Alexander A. Oraevsky , Mark A. Anastasio

Optical coherence tomography (OCT) uses low-coherence reflectometry to obtain cross-sectional images of inhomogeneous media, such as biological tissue. OCT is particularly useful in the biomedical ea, since the imaging can be performed…

Medical Physics · Physics 2018-03-01 Takahisa Mitsui , Kenichiro Aoki

This paper aims to evaluate mid-infrared (MIR) Optical Coherence Tomography (OCT) systems as a tool to penetrate different materials and detect sub-surface irregularities. This is useful for monitoring production processes, allowing…

Atomic probe tomography (APT), based on the work of Erwin Mueller, is able to generate three-dimensional chemical maps in atomic resolution. The required instruments for APT have evolved over the last 20 years from an experimental to an…

In tomographic reconstruction, the image quality of the reconstructed images can be significantly degraded by defects in the measured two-dimensional (2D) raw image data. Despite the importance of screening defective 2D images for robust…

Image and Video Processing · Electrical Eng. & Systems 2019-10-29 Donghun Ryu , Youngju Jo , Jihyeong Yoo , Taean Chang , Daewoong Ahn , Young Seo Kim , Geon Kim , Hyun-seok Min , Yongkeun Park

Metal artifact reduction (MAR) is a challenging problem in computed tomography (CT) imaging. A popular class of MAR methods replace sinogram measurements that are corrupted by metal with artificial data. While these ``projection…

Medical Physics · Physics 2021-01-27 T. Humphries , J. Wang

Motion, e.g., due to patient movement or improper device calibration, is inevitable in many imaging modalities such as photoacoustic tomography (PAT) by a rotating system and can lead to undesirable motion artifacts in image…

Numerical Analysis · Mathematics 2016-09-28 Julianne Chung , Linh Nguyen

We consider the imaging problem of the reconstruction of a three-dimensional object via optical diffraction tomography under the assumptions of the Born approximation. Our focus lies in the situation that a rigid object performs an…

Numerical Analysis · Mathematics 2024-07-11 Robert Beinert , Michael Quellmalz