English
Related papers

Related papers: The trigger system for the CSR external-target exp…

200 papers

CLIC is a proposed linear $e^{+}e^{-}$ collider with center-of-mass energies of up to $3\,\textrm{TeV}$. Its main objectives are precise top quark and Higgs boson measurements, as well as searches for Beyond Standard Model physics. To meet…

Instrumentation and Detectors · Physics 2018-12-07 Simon Spannagel

Since May 1999 the BABAR detector has been taking data at the PEP-II asymmetric electron-positron collider at the Stanford Linear Accelerator Center, California. This experiment requires a very large data sample and the PEP-II accelerator…

High Energy Physics - Experiment · Physics 2014-11-17 P. D. Dauncey

We give an overview of the main features of the CMS trigger and data acquisition (DAQ) system. Then, we illustrate the strategies and trigger configurations (trigger tables) developed for the detector calibration and physics program of the…

Instrumentation and Detectors · Physics 2019-08-13 Marta Felcini

Coherent elastic neutrino-nucleus scattering (CE$\nu$NS) offers a valuable approach in searching for physics beyond the Standard Model. The Ricochet experiment aims to perform a precision measurement of the CE$\nu$NS spectrum at the…

Instrumentation and Detectors · Physics 2022-12-21 R. Chen , H. Douglas Pinckney , E. Figueroa-Feliciano , Z. Hong , B. Schmidt

Energy constraint long-range wireless sensor/ actuator based solutions are theoretically the perfect choice to support the next generation of city-scale cyber-physical systems. Traditional systems adopt periodic control which increases…

Systems and Control · Computer Science 2016-11-15 Sokratis Kartakis , Anqi Fu , Manuel Mazo , Julie A. McCann

The CMS experiment has been designed with a two-level trigger system: the Level 1 (L1) Trigger, implemented on custom-designed electronics, and the High Level Trigger (HLT), a streamlined version of the CMS reconstruction and analysis…

Instrumentation and Detectors · Physics 2014-09-16 Zeynep Demiragli

The CDF experiment's Silicon Vertex Trigger is a system of 150 custom 9U VME boards that reconstructs axial tracks in the CDF silicon strip detector in a 15 microsecond pipeline. SVT's 35 micron impact parameter resolution enables CDF's…

Instrumentation and Detectors · Physics 2012-08-27 CDF Collaboration

In balancing safety with the nominal control objectives, e.g., stabilization, it is desirable to reduce the time period when safety filters are in effect. Inspired by traditional spacecraft maneuvers, and with the ultimate goal of reducing…

Systems and Control · Electrical Eng. & Systems 2023-04-19 Pio Ong , Aaron D. Ames

We present a method for the evaluation, at the first level of trigger, of logical conditions with high time resolution, using the digitized times of fast signals delivered in the detectors of high rate experiments. We describe a…

Instrumentation and Detectors · Physics 2010-05-12 E. Imbergamo , A. Nappi , A. Papi , A. Riccini , M. Valdata

The ICARUS liquid argon TPC detector is taking data on the Booster (BNB) and Main Injector (NuMI) Neutrino beam lines at Fermilab with a trigger system based on the scintillation light produced by charged particles in coincidence with the…

High Energy Physics - Experiment · Physics 2026-02-19 ICARUS collaboration , F. Abd Alrahman , P. Abratenko , N. Abrego-Martinez , A. Aduszkiewicz , F. Akbar , L. Aliaga Soplin , M. Artero Pons , J. Asaadi , W. F. Badgett , B. Baibussinov , F. Battisti , V. Bellini , R. Benocci , J. Berger , S. Berkman , S. Bertolucci , M. Betancourt , A. Blanchet , F. Boffelli , M. Bonesini , T. Boone , B. Bottino , A. Braggiotti , D. Brailsford , S. J. Brice , V. Brio , C. Brizzolari , H. S. Budd , A. Campani , A. Campos , D. Carber , M. Carneiro , I. Caro Terrazas , H. Carranza , F. Castillo Fernandez , S. Centro , G. Cerati , A. Chatterjee , D. Cherdack , S. Cherubini , N. Chithirasreemadam , M. Cicerchia , T. E. Coan , A. Cocco , M. R. Convery , L. Cooper-Troendle , S. Copello , H. Da Motta , M. Dallolio , A. A. Dange , A. de Roeck , S. Di Domizio , D. Di Ferdinando , L. Di Noto , M. Diwan , S. Dolan , L. Domine , S. Donati , F. Drielsma , J. Dyer , S. Dytman , A. Falcone , C. Farnese , A. Fava , N. Gallice , F. G. Garcia , C. Gatto , D. Gibin , A. Gioiosa , W. Gu , A. Guglielmi , G. Gurung , K. Hassinin , H. Hausner , A. Heggestuen , B. Howard , R. Howell , Z. Hulcher , I. Ingratta , C. James , W. Jang , Y. -J. Jwa , L. Kashur , W. Ketchum , J. S. Kim , D. -H. Koh , T. Krishnan , J. Larkin , Y. Li , C. Mariani , C. M. Marshall , S. Martynenko , N. Mauri , K. S. McFarland , A. Menegolli , G. Meng , O. G. Miranda , A. Mogan , N. Moggi , E. Montagna , A. Montanari , C. Montanari , M. Mooney , G. Moreno-Granados , J. Mueller , M. Murphy , D. P. Méndez , D. Naples , S. Palestini , M. Pallavicini , V. Paolone , L. Pasqualini , L. Patrizii , L. Paudel , G. Petrillo , C. Petta , V. Pia , F. Pietropaolo , F. Poppi , M. Pozzato , M. L. Pumo , G. Putnam , X. Qian , A. Rappoldi , G. L. Raselli , S. Repetto , F. Resnati , A. M. Ricci , E. Richards , M. Rosenberg , M. Rossella , N. Rowe , P. Roy , C. Rubbia , M. Saad , S. Saha , G. Salmoria , S. Samanta , A. Scaramelli , D. Schmitz , A. Schukraft , D. Senadheera , S-H. Seo , F. Sergiampietri , G. Sirri , J. S. Smedley , J. Smith , M. Sotgia , L. Stanco , J. Stewart , H. A. Tanaka , M. Tenti , K. Terao , F. Terranova , V. Togo , D. Torretta , M. Torti , F. Tortorici , D. Totani , R. Triozzi , Y. -T. Tsai , K. V. Tsang , T. Usher , F. Varanini , N. Vardy , S. Ventura , M. Vicenzi , C. Vignoli , B. Viren , F. A. Wieler , Z. Williams , P. Wilson , R. J. Wilson , J. Wolfs , T. Wongjirad , A. Wood , E. Worcester , M. Worcester , M. Wospakrik , J. Xia , S. Yadav , H. Yu , J. Yu , A. Zani , J. Zennamo , J. Zettlemoyer , C. Zhang , S. Zucchelli

The Large Underground Xenon experiment (LUX) searches for dark matter using a dual-phase xenon detector. LUX uses a custom-developed trigger system for event selection. In this paper, the trigger efficiency, which is defined as the…

The DZERO experiment, located at the Fermi National Accelerator Laboratory, has recently started the Run 2 physics program. The detector upgrade included a new Data Acquisition/Level 3 Trigger system. Part of the design for the DAQ/Trigger…

The next generation of circular high energy collider is expected to be a lepton collider, FCC-ee at CERN or CEPC in China. However, the civil engineering concepts foresee to equip these colliders with bigger detector caverns than one would…

High Energy Physics - Phenomenology · Physics 2021-06-30 Marcin Chrzaszcz , Marco Drewes , Jan Hajer

KLOE, a new state of the art detector recently commissioned for physics operation at DAFNE, has many innovative interesting features, especially in the DAQ and Trigger areas. Custom electronics assert a trigger in a 2 microseconds decision…

High Energy Physics - Experiment · Physics 2012-08-27 The KLOE Collaboration

The Zero Degree Calorimeter (ZDC) plays a crucial role in determining centrality at the Cooling-Storage-Ring External-target Experiment (CEE) in the Heavy Ion Research Facility in Lanzhou (HIRFL). A Boosted Decision Trees (BDT)…

Instrumentation and Detectors · Physics 2023-05-01 Biao Zhang , Li-Ke Liu , Hua Pei , Shusu Shi , Nu Xu , Yaping Wang

This article proposes a periodic event-triggered adaptive barrier control policy for the trajectory tracking problem of perturbed Euler-Lagrangian systems with state, input, and temporal (SIT) constraints. In particular, an…

Systems and Control · Electrical Eng. & Systems 2025-10-06 Chidre Shravista Kashyap , Karnan A , Pushpak Jagtap , Jishnu Keshavan

Confining dark sectors at the GeV scale can lead to novel collider signatures including those termed emerging jets with large numbers of displaced vertices. The triggers at the LHC experiments were not designed with this type of new physics…

High Energy Physics - Phenomenology · Physics 2021-08-25 Dylan Linthorne , Daniel Stolarski

We derive a new method to improve the statistics of identified particles at high transverse momentum (\pt) using online-triggered events by the Barrel Electro-Magnetic-Calorimeter (BEMC) detector. The BEMC is used to select hadronic…

High Energy Physics - Experiment · Physics 2011-12-20 Hongyu Da , Xiangli Cui , Gene Van Buren , J. C. Dunlop , Xin Dong , Lijuan Ruan , Anthony Timmins , Zebo Tang , Xiaolian Wang , Yichun Xu , Zhangbu Xu

This paper studies a Coded Event-triggered Control (CEC) for a class of nonlinear systems under any initial condition. To reduce communication burden, the CEC is designed from the encoding-decoding viewpoint by which only $m$-length string…

Systems and Control · Electrical Eng. & Systems 2024-05-14 Ruihang Ji , Shuzhi Sam Ge , Kai Zhao

We present a dedicated experimental setup which is currently used to search for long lived super heavy elements (SHE) implanted in catcher scintillators which were irradiated by reaction products of $^{197}$Au (7.5 A.MeV) projectile and…