English
Related papers

Related papers: Microstructured Plastic Scintillators For Beam Pro…

200 papers

Plastic scintillator detectors are widely used in particle physics thanks to the very good particle identification, tracking capabilities and time resolution. However, new experimental challenges and the need for enhanced performance…

Instrumentation and Detectors · Physics 2020-11-20 S. Berns , A. Boyarintsev , S. Hugon , U. Kose , D. Sgalaberna , A. De Roeck , A. Lebedynskiy , T. Sibilieva , P. Zhmurin

Laser beam profilometry is an important scientific task with well-established solutions for beams propagating in air. It has, however, remained an open challenge to measure beam profiles of high-power lasers in ultra-high vacuum and in…

Instrumentation and Detectors · Physics 2020-04-08 Christian Brand , Ksenija Simonović , Filip Kiałka , Stephan Troyer , Philipp Geyer , Markus Arndt

To investigate the 1.6 GeV high-energy proton beam detector utilized in the CSNS Phase-II upgrade project, a plastic scintillator detector presents a viable option due to its superior radiation hardness. This study investigates the effects…

Instrumentation and Detectors · Physics 2023-09-11 Yue Zhang , Ruirui Fan , Yuhong Yu , Hantao Jing , Zhixin Tan , Yuhang Guo , You Lv

We present a new conceptual radiation detector, the Architected Multimaterial Scintillator System, that utilizes a scintillator composed of multiple materials arranged in architected structures to enable new capabilities. By structuring…

Instrumentation and Detectors · Physics 2021-03-11 Xianyi Zhang , Jason Philip Brodsky , Elaine Lee , Andrew Neil Mabe , Dominique Porcincula

Fast procedures for the beam quality assessment and for the monitoring of beam energy modulations during the irradiation are among the most urgent improvements in particle therapy. Indeed, the online measurement of the particle beam energy…

Organic scintillators using a solid polyurethane (PU) matrix have been introduced to combine the robustness of a construction material with scintillating properties that allow gamma rays and fast neutrons to be detected efficiently and at…

Instrumentation and Detectors · Physics 2026-01-27 Olga Maiatska , Torsten Dünnebacke , Martin Kreuels , Guntram Pausch , Falko Scherwinski , Jürgen R. Stein

Thin film detectors which incorporate semiconductor materials other than silicon have the potential to build upon their unique material properties and offer advantages such as faster response times, operation at room temperature, and…

Instrumentation and Detectors · Physics 2024-04-22 Sungjoon Kim , Manoj B. Jadhav , Vikas Berry , Jessica E. Metcalfe , Anirudha V. Sumant

This paper describes a novel idea of a fine-grained fully-active plastic scintillator detector made of many optically independent $1\times1\times1~\text{cm}^3$ cubes with readout on three orthogonal projections by wavelength shifting…

A novel composite, scintillating material intended for neutron detection and composed of small (1.5 mm) cubes of KG2-type lithium glass embedded in a matrix of scintillating plastic has been developed in the form of a 2.2 in.-diameter, 3.1…

Instrumentation and Detectors · Physics 2015-05-27 G. C. Rich , K. Kazkaz , H. P. Martinez , T. Gushue

Plastic-scintillator detectors are devices used for the detection of elementary particles. They provide good particle identification with excellent time resolution, whilst being inexpensive due to the affordability of plastic materials.…

Introduction: Real-time dosimetry of surface doses in electron beams has not been widely established yet. Plastic scintillation detectors (PSD) promise high spatial resolution and real-time dosimetry with minimum perturbation of the…

Inorganic scintillators are widely used for scientific, industrial and medical applications. The development of 3D printing with inorganic scintillators would allow fast creation of detector prototypes for registration of ionizing…

A plastic scintillator bar with dimensions 300 cm x 2.5 cm x 11 cm was exposed to a focused muon beam to study its light yield and timing characteristics as a function of position and angle of incidence. The scintillating light was read out…

Instrumentation and Detectors · Physics 2017-08-07 A. Blondel , D. Breton , A. Dubreuil , A. Khotyantsev , A. Korzenev , J. Maalmi , A. Mefodev , P. Mermod , E. Noah

A radio-guided surgery technique exploiting $\beta^-$ emitters is under development. It aims at a higher target-to-background activity ratio implying both a smaller radiopharmaceutical activity and the possibility of extending the technique…

The performance of scintillator counters with embedded wavelength-shifting fibers has been measured in the Fermilab Meson Test Beam Facility using 120 GeV protons. The counters were extruded with a titanium dioxide surface coating and two…

This work reports on the performance of a novel neutron-sensitive scintillating detector fabricated using Fused-Deposition Modelling (FDM) additive manufacturing. FDM is a cost-effective 3D-printing method employing flexible plastic…

Instrumentation and Detectors · Physics 2025-10-07 Adam Barr , Cinzia da Vià , Mosst Tasnim Binte Shawkat , Stephen Watts , John Allison , Gabriele D'Amen , Tianqi Gao

We have studied the possibility of using Geiger mode multi-pixel photodiodes to read out long scintillator bars with a single wavelength-shifting fiber embedded along the bar. This detector configuration can be used in large volume…

Instrumentation and Detectors · Physics 2015-05-30 O. Mineev , Yu. Kudenko , Yu. Musienko , I. Polyansky , N. Yershov

Large-scale particle physics detectors often contain millions of repeated components, making precise and efficient quality control essential. We have developed a semiautomatic system for dimensional screening of 1 cm$^3$ plastic…

Instrumentation and Detectors · Physics 2026-03-31 Tatsuya Kikawa , Mao Tani , Atsuko K. Ichikawa , Tsunayuki Matsubara , Tsuyoshi Nakaya , Tomohisa Ogawa

We demonstrate, for the first time, the applicability of 3D printing technique to the manufacture of scintillation detectors. We report of a formulation, usable in stereolithographic printing, that exhibits scintillation efficiency on the…

Materials Science · Physics 2014-06-20 Y. Mishnayot , M. Layani , I. Cooperstein , S. Magdassi , G. Ron

We present prototype modules for a tracking detector consisting of multiple layers of 0.25 mm diameter scintillating fibers that are read out by linear arrays of silicon photomultipliers. The module production process is described and…