English
Related papers

Related papers: Dual-sided Charge-Coupled Devices

200 papers

The current understanding of charge transfer dynamics in Charge-Coupled Devices (CCDs) is that charge is moved so quickly from one phase to the next in a clocking sequence and with a density so low that trapping of charge in the inter-phase…

Instrumentation and Methods for Astrophysics · Physics 2018-01-04 Jesper Skottfelt , David J. Hall , Ben Dryer , Nathan Bush , Jason Gow , Andrew Holland

Charge-Coupled Device (CCD) detectors, widely used to obtain digital imaging, can be damaged by high energy radiation. Degraded images appear blurred, because of an effect known as Charge Transfer Inefficiency (CTI), which trails bright…

Instrumentation and Methods for Astrophysics · Physics 2014-03-05 Richard Massey , Tim Schrabback , Oliver Cordes , Ole Marggraf , Holger Israel , Lance Miller , David Hall , Mark Cropper , Thibaut Prod'homme , Sami-Matias Niemi

In this work, we will present a physical model and measurements of the transport of small charge packets in the bulk of thick high resistivity CCD before being collected by the pixel potential wells. A new technique to measure the lateral…

Instrumentation and Detectors · Physics 2019-06-28 Miguel Sofo Haro , Guillermo Fernandez Moroni , Javier Tiffenberg

Position-sensitive detectors for cold and ultra-cold neutrons (UCN) are in use in fundamental research. In particular, measuring the properties of the quantum states of bouncing neutrons requires micro-metric spatial resolution. To this…

Instrumentation and Detectors · Physics 2017-11-16 O. Bourrion , B. Clement , D. Tourres , G. Pignol , Y. Xi , D. Rebreyend , V. V. Nesvizhevsky

Charge-coupled devices (CCDs) are a leading technology in direct dark matter searches because of their eV-scale energy threshold and high spatial resolution. The sensitivity of future CCD experiments could be enhanced by distinguishing…

We characterize the response of a novel 250 $\mu$m thick, fully-depleted Skipper Charged-Coupled Device (CCD) to visible/near-infrared light with a focus on potential applications for astronomical observations. We achieve stable,…

We present the two kinds of experimental results. One is a continuous variable dense coding experiment, and the other is a photon number detector with high linearity response, the so called charge integration photon detector (CIPD). They…

Quantum Physics · Physics 2007-05-23 M. Sasaki , K. Wakui , J. Mizuno , M. Fujiwara , M. Akiba

A dedicated simulator, Poisson_CCD, has been constructed which models astronomical CCDs by solving Poisson's equation numerically and simulating charge transport within the CCD. The potentials and free carrier densities within the CCD are…

Instrumentation and Methods for Astrophysics · Physics 2021-11-10 Craig Lage , Andrew K. Bradshaw , J. Anthony Tyson

This paper presents the design and results of detailed tests of a CMOS active pixel chip for charged particle detection with in-pixel charge storage for correlated double sampling and readout in rolling shutter mode at frequencies up to 25…

Instrumentation and Detectors · Physics 2016-11-17 Marco Battaglia , Jean-Marie Bussat , Devis Contarato , Peter Denes , Piero Giubilato , Lindsay E. Glesener

Multiple-Amplifier Sensing (MAS) charge-coupled devices (CCDs) have recently been shown to be promising silicon detectors that meet noise sensitivity requirements for next generation Stage-5 spectroscopic surveys and potentially, future…

Instrumentation and Methods for Astrophysics · Physics 2025-04-30 Kenneth W. Lin , Abby Bault , Armin Karcher , Julien Guy , Stephen E. Holland , William F. Kolbe , Peter E. Nugent

This paper presents the development of a new technology of registration of ionizing radiation and a new type of detectors - single-cathode multiwire porous detector with neither a gaseous nor semiconductor, but a porous dielectric…

Instrumentation and Detectors · Physics 2015-06-26 M. P. Lorikyan

Electron Multiplying CCDs (EMCCDs) are used much less often than they might be because of the challenges they offer camera designers more comfortable with the design of slow-scan detector systems. However they offer an entirely new range of…

Instrumentation and Methods for Astrophysics · Physics 2015-06-05 Craig Mackay , Keith Weller , Frank Suess

We have designed and built a new type of CCD that we call an orthogonal transfer CCD (OTCCD), which permits parallel clocking horizontally as well as vertically. The device has been used successfully to remove image motion caused by…

Astrophysics · Physics 2007-05-23 John L. Tonry , Barry E. Burke , Paul L. Schechter

We introduce the fully-depleted charge-coupled device (CCD) as a particle detector. We demonstrate its low energy threshold operation, capable of detecting ionizing energy depositions in a single pixel down to 50 eVee. We present results of…

A pixel detector with a CVD diamond sensor has been studied in a 180 GeV/c pion beam. The charge collection properties of the diamond sensor were studied as a function of the track position, which was measured with a silicon microstrip…

Instrumentation and Detectors · Physics 2009-11-10 T. Lari , A. Oh , N. Wermes , H. Kagan , M. Keil , W. Trischuk

We demonstrate the application of two-photon absorption transient current technique to wide bandgap semiconductors. We utilize it to probe charge transport properties of single-crystal Chemical Vapor Deposition (scCVD) diamond. The charge…

Instrumentation and Detectors · Physics 2021-01-22 C. Dorfer , D. Hits , L. Kasmi , G. Kramberger , M. Lucchini , M. Mikuz , R. Wallny

A Scintillator Deposited CCD (SDCCD) is a wide-band X-ray detector consisting of a CCD and a scintillator directly attached to each other. We assembled the newly developed SDCCD that the scintillator CsI(Tl) is below the fully depleted CCD.…

Instrumentation and Methods for Astrophysics · Physics 2010-10-01 Hiroshi Tsunemi , Shutaro Ueda , Kazuo Shigeyama , Koji Mori , Shoichi Aoyama , Shin'ichiro Takagi

We have constructed and tested a 2d position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position dependent charge…

Instrumentation and Detectors · Physics 2009-11-10 F. Gomez , A. Iglesias , R. Lobato , J. Mosquera , J. Pardo , J. Pena , A. Pazos , M. Pombar , A. Rodriguez

Skipper Charge-Coupled Devices (skipper-CCDs) are pixelated silicon detectors with deep sub-electron resolution. Their radiation hardness and capability to reconstruct energy deposits with unprecedented precision make them a promising…

Instrumentation and Methods for Astrophysics · Physics 2026-05-11 Ana M. Botti , Yikai Wu , Brenda Cervantes , Claudio Chavez , Juan Estrada , Stephen E. Holland , Nathan Saffold , Javier Tiffenberg , Sho Uemura

Digital correlated double sampling (DCDS), a readout technique for charge-coupled devices (CCD), is gaining popularity in astronomical applications. By using an oversampling ADC and a digital filter, a DCDS system can achieve a better…

Instrumentation and Methods for Astrophysics · Physics 2015-11-23 Cristobal Alessandri , Angel Abusleme , Dani Guzman , Ignacio Passalacqua , Enrique Alvarez-Fontecilla , Marcelo Guarini