English
Related papers

Related papers: PIP-II SSR2 Cavities Fabrication and Processing Ex…

200 papers

Surface preparation of niobium superconducting RF cavities is a critical step for achieving good RF performance under the superconducting state. Surface defect, roughness, and contamination affect the accelerating gradient and quality…

Accelerator Physics · Physics 2023-07-21 V. Chouhan , D. Bice , D. Burk , M. K. Ng , G. Wu

A prototype cryomodule containing eight Single Spoke Resonators type-1 (SSR1) operating at 325 MHz and four superconducting focusing lenses was successfully assembled, cold tested, and accelerated beam in the framework of the PIP-II project…

PIP-II is the Fermilab's flagship project for providing powerful, high-intensity proton beams to the laboratory's experiments. The heart of PIP-II is an 800-MeV superconducting linac accelerator. It will be located in a new tunnel with new…

Accelerator Physics · Physics 2018-06-18 L. Lari , F. Cerutti , L. S. Esposito , C. Baffes , S. J. Dixon , N. V. Mokhov , I. Rakhno , I. S. Tropin

PIP-II is an essential upgrade of the Fermilab complex that will enable the worlds most intense high-energy beam of neutrinos for the international Deep Underground Neutrino Experiment at LBNF and support a broad physics program at…

Accelerator Physics · Physics 2022-09-07 Abhishek Pathak , Eduard Pozdeyev

The Proton Improvement Plan - II (PIP-II) is a new linear accelerator (LINAC) complex being built at Fermilab. It is based on superconducting radiofrequency cavities and will accelerate H- ions to 800 MeV kinetic energy before injection…

Accelerator Physics · Physics 2023-10-05 R. Thurman-Keup , M. El Baz , V. Scarpine

The central part of PIP-II program of upgrades pro-posed for the Fermilab injection complex is an 800 MeV, 2 mA, CW-compatible SRF linac. Acceleration in super-conducting cavities begins from a low energy of 2.1 MeV, so that the first…

Accelerator Physics · Physics 2019-12-09 A. Chen , R. Andrews , C. Baffes , D. Lambert , L. Prost , A. Shemyakin , T. Zuchnik

The U.S. Particle Physics Project Prioritization Panel (P5) report encouraged the realization of Fermilab's Proton Improvement Plan II (PIP-II) to support future neutrino programs in the United States. PIP-II aims at enhancing the…

Accelerator Physics · Physics 2017-01-05 A. Vivoli

Titanium and niobium are the main materials used for the fabrication of Superconducting Radio Frequency (SRF) cavities. These two metals are usually joined , using various welding techniques, using a third material in between. This…

Accelerator Physics · Physics 2022-09-07 M. Parise , D. Passarelli , J. Bernardini

A CW-compatible, pulsed H- superconducting linac "PIP-II" is being planned to upgrade Fermilab's injection complex. To validate the front-end concept, a test accelerator (The PIP-II Injector Test, formerly known as "PXIE") is under…

The PIP-II linac is an international collaboration project with in kind contributions of key subsystems from multiple countries including India (DAE). In the research and development phase of the project, the LLRF and resonance control…

Accelerator Physics · Physics 2025-10-21 R. Nasery , P. Varghese , S. Raman , M. Guran , L. Reyes , A. Agashe

The PIP-II accelerator is a proposed upgrade to the Fermilab accelerator complex that will replace the existing, 400 MeV room temperature LINAC with an 800 MeV superconducting LINAC. Part of this upgrade includes a new injection scheme into…

A single gap, 352 MHz superconducting reentrant cavity for 5-100 MeV beams has been designed and it is presently under construction. This development is being done in the framework of a 30 mA proton linac project for nuclear waste…

Accelerator Physics · Physics 2009-10-05 A. Facco , M. Pasini , V. Zviagintsev

There are many stages in the LLRF and RF system development process for any new accelerator that can take advantage of hardware emulation of the high-power RF system and RF cavities. LLRF development, bench testing, control system…

Accelerator Physics · Physics 2022-10-20 Ahmed Syed , Brian Chase , Philip Varghese , Sana Begum

In order to update the beam power from 100 kW to 250 kW in China spallation neutron source (CSNS) Phase II, one of the important measures is to replace the 80 meters long beam transport line between the present 80 MeV linac injector and the…

Accelerator Physics · Physics 2015-07-14 LI Zhi-Hui , FU Shi-Nian

The Proton Improvement Plan II (PIP-II) at Fermilab is a program of upgrades to the injection complex. At its core is the design and construction of a CW-compatible, pulsed H- superconducting RF linac. To validate the concept of the…

Accelerator Physics · Physics 2015-11-05 L. Prost , M. Alvarez , R. Andrews , J. -P. Carneiro , B. Hanna , V. Scarpine , A. Shemyakin , R. D'Arcy , C. Wiesner

Fermilab is developing a Proton Improvement Plan (PIP) to increase throughput of its proton source. The plan addresses hardware modifications to increase repetition rate and improve beam loss while ensuring viable operation of the proton…

The LCLS-II HE superconducting linac can produce multi-energy beams by supporting multiple undulator lines simultaneously. This could be achieved by using the cavity SRF tuner in the off-frequency detune mode. This off-frequency operation…

The injector (Scheme-I) of the C-ADS linac is a 10-mA 10-MeV proton linac working in CW mode. It is mainly comprised of a 3.2-MeV room-temperature 4-vane RFQ and twelve superconducting single-spoke cavities housed in a long cryostat. Error…

Accelerator Physics · Physics 2015-06-16 Cai Meng , Zhihui Li , Jingyu Tang

The Proton Improvement Plan, Stage Two (PIP-II) is a program of upgrades proposed for the Fermilab injection complex, which central part is an 800 MeV, 2 mA CW SRF linac. A prototype of the PIP-II linac front end called PIP-II Injector Test…

Accelerator Physics · Physics 2018-08-28 A. Shemyakin , J. -P. Carneiro , B. Hanna , V. Lebedev , L. Prost , A. Saini , V. Scarpine , V. L. S. Sista , C. Richard

After shipment to the Daresbury Lab and return to Fermilab, the prototype HB650 cryomodule underwent another phase of 2K RF testing to ascertain any performance issues that may have arisen from the transport of the cryomodule. While…