A CW-compatible, pulsed H- superconducting linac is envisaged as a possible path for upgrading Fermilab's injection complex. To validate the concept of the front- end of such a machine, a test accelerator (a.k.a. PXIE) is under…

Accelerator Physics · Physics 2015-02-06 A. Shemyakin , M. Alvarez , R. Andrews , C. Baffes , A. Chen , B. Hanna , L. Prost , G. Saewert , V. Scarpine , J. Steimel , D. Sun , D. Li , R. D'Arcy

The mostly research fasten on high emission density of injector to study electron beam's brightness in LIA. Using the injector(2MeV) was built to research brightness of multi-pulsed high current(KA) electron beam, and researchs three…

Accelerator Physics · Physics 2015-10-22 Yuan Wang , XiaoGuo Jiang , Huang Zhang , GuoJun Yang , YiDing Li , Jin Li

Within the framework of the European, project MYRTE (MYRRHA Research and Transmutation Endeavour) of the H2020 program, a 4-Rods RFQ (Radio Frequency Quadrupole) has been designed at 176.1 MHz RFQ for accelerating up to 4 mA protons in CW…

The 75-keV injector and 6.7-MeV RFQ that comprise the first portion of the cw, 100-mA proton linac for the accelerator production of tritium (APT) project have been built and operated. The LEDA RFQ has been extensively tested for pulsed and…

Accelerator Physics · Physics 2012-08-27 H. Vernon Smith, , J. David Schneider

Access to high-energy particle beams is key for testing high-energy physics (HEP) instruments. Accelerators for cancer treatment can serve as such a testing ground. However, HEP instrument tests typically require particle fluxes…

A 5-MeV RFQ designed for a proton current up to 100-mA CW is now under construction as part of the High Intensity Proton Injector project (IPHI). Its computed transmission is greater than 99 %. The main goals of the project are to verify…

The interest in plasma-based accelerators as drivers of user facilities is growing worldwide thanks to its compactness and reduced costs. In this context the EuPRAXIA collaboration is preparing a conceptual design report for a multi-GeV…

A microwave ion source is used as an ion source of 100-MeV proton accelerator at Korea Multipurpose Accelerator Complex (KOMAC). The specifications of the ion source are 50 keV in energy and 20 mA in peak current. The plasma is operated in…

Accelerator Physics · Physics 2016-11-03 Hyeok-Jung Kwon

Typical front-ends of modern light-ion high-intensity accelerators typically consist of an ion source, a Low Energy Beam Transport (LEBT), a Radiofrequency Quadrupole (RFQ) and a Medium Energy Beam Transport (MEBT), which is followed by the…

Accelerator Physics · Physics 2017-04-17 L. Prost , A. Shemyakin

A compact beam-profile monitor was constructed using a linear contact image sensor attached to a plastic scintillator and tested using a 230 MeV proton beam. The results indicate that the beam distribution can be obtained in real-time, and…

Medical Physics · Physics 2019-12-23 Tung-Yuan Hsiao , Tzung-Yuang Chen , Huan Niu , Chien-Hsu Chen

An ion beam cooler and buncher has been developed for the manipulation of radioactive ion beams. The gas-filled linear radiofrequency ion trap system is installed at the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. Its purpose is…

The development of instrumentation for operation in high-radiation environments represents a challenge in various research fields, particularly in particle physics experiments and space missions, and drives an ever-increasing demand for…

The Fermilab Booster uses multi-turn beam injection with all its cavities phased such that beam sees a net zero RF voltage even when each station is at the same maxi-mum voltage. During beam capture the RF voltage is increased slowly by…

A radially-coupled coaxial fast Faraday cup design was presented in [1] for high-intensity non-relativistic proton beams. In this work, we discuss a modification of that design in the context of a relatively lower intensity ion beam for…

Accelerator Physics · Physics 2024-06-19 K. Mal , S. Kumar , G. Rodrigues , R. Singh

We present an innovative charge detector with high resolution and wide dynamic range designed to fulfill the requirements of a monitoring system for a high energy ion beam. The detector prototype, constructed using Si photodiodes and a…

A RadioFrequency Quadrupole (RFQ) cooler-buncher system has been developed and implemented in a collinear laser spectroscopy setup. This system is dedicated to convert a continuous ion beam into short bunches, while enhancing beam quality…

This work describes the architecture of a digital LLRF system for heavy-ion acceleration developed under the specification of the projected future heavy-ion accelerator facility in Huelva, Spain. A prototype LLRF test bench operating at…

Accelerator Physics · Physics 2014-06-17 I. Badillo J. Jugo , J. Portilla , J. Feutchwanger , C. San Vicente , V. Etxebarria

The FLASHForward experimental facility is a high-performance test-bed for precision plasma-wakefield research, aiming to accelerate high-quality electron beams to GeV-levels in a few centimetres of ionised gas. The plasma is created by…

The FLASH L-band (1.3 GHz) superconducting accelerator facility at DESY has a Low Level RF (LLRF) system that is similar to that envisioned for ILC. This system has extensive monitoring capability and was used to gather performance data…

Accelerator Physics · Physics 2009-03-10 Shilun Pei , Chris Adolphsen , John Carwardine

The UNILAC was improved for high current performance by replacing the Wideroe prestripper accelerator by an RFQ and an IH-type DTL. In addition, one of two ion source terminals was equipped with high current sources of MUCIS- and…

Accelerator Physics · Physics 2016-09-08 L. Dahl , P. Spaedtke