Related papers: Electromagnetic calorimeter time measurement appli…
The process $e^+e^- \to \pi^0\gamma$ is studied with the SND detector at the VEPP-2000 $e^+e^-$ collider. Basing on data with an integrated luminosity of 41 pb$^{-1}$ recorded in 2010-2012 we measure the $e^+e^- \to \pi^0\gamma$ cross…
The current status of experiments with SND detector at VEPP-2M e^+e^- collider in the energy range 2E_0=400-1400 MeV and recent results of data analysis for $\phi$, $\omega$ and $\rho$ decays and e^+e^- annihilation into hadrons are…
A silicon-tungsten (Si-W) sampling calorimeter, consisting of 19 alternate layers of silicon pad detectors (individual pad area of 1~cm$^2$) and tungsten absorbers (each of one radiation length), has been constructed for measurement of…
The paper describes a method of the charged particle identification, developed for the \mbox{CMD-3} detector, installed at the VEPP-2000 $e^{+}e^{-}$ collider. The method is based on the application of the boosted decision trees…
The electromagnetic ealorimeter (ECAL) of the CMS detector has played an important role in the physics program of the experiment, delivering outstanding performance throughout data taking. The High-Luminosity LHC will pose new challenges.…
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling…
The technique of discrimination of the $e^+e^-\to e^+e^-$ and $e^+e^-\to \pi^+\pi^-$ events in energy range $0.5 < \sqrt{s} < 1$ GeV by energy deposition in the calorimeter of SND detector was developed by applying machine learning method.…
While the CMS experiment is currently harvesting LHC collision data at CERN, the performance of its electromagnetic calorimeter (ECAL) is being constantly monitored, and work has started to assess the need for changes to the detector to…
The electromagnetic calorimeter (ECAL) of the AMS-02 experiment is a 3-dimensional sampling calorimeter, made of lead and scintillating fibers. The detector allows for a high granularity, with 18 samplings in the longitudinal direction, and…
We present a design for a high-granularity zero-degree calorimeter (ZDC) for the upcoming Electron-Ion Collider (EIC). The design uses SiPM-on-tile technology and features a novel staggered-layer arrangement that improves spatial…
In the experiment with the SND detector at the VEPP-2000 $e^+e^-$ collider, the $e^+e^-\to\eta\gamma$ cross section is measured in the energy range $E = 980 - 1060$ MeV. The measurement is carried out in the $\eta\to 2\gamma$ decay mode.…
The review of experimental results obtained with SND detector at VEPP-2M $e^+e^-$ collider in the energy region $\sqrt[]{s}=0.36$ -- 1.38 GeV is given. The presented results include the following items: studies of the light vector mesons…
We present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage…
We analyze a 37 pb$^{-1}$ data sample collected with the SND detector at the VEPP-2000 $e^+e^-$ collider in the center-of-mass energy range 1.05--2.00 GeV and present an updated measurement of the $e^+e^- \to \omega \pi^0 \to…
The COMPASS experiment at the CERN SPS is dedicated to hadron physics with a broad research programme, including the study of the nucleon spin structure using muons as a probe and a variety of issues in meson spectroscopy using hadron…
A prototype Silicon-Tungsten electromagnetic calorimeter (ECAL) for an International Linear Collider (ILC) detector was installed and tested during summer and autumn 2006 at CERN. The detector had 6480 silicon pads of dimension 1x1 cm^2.…
The cross section of the process $e^+ e^-\to\pi^+\pi^-$ has been measured in the Spherical Neutral Detector (SND) experiment at the VEPP-2000 $e^+e^-$ collider VEPP-2000 in the energy region $525 <\sqrt[]{s} <883$ MeV. The measurement is…
A novel design for a silicon-tungsten electromagnetic calorimeter is described, based on Monolithic Active Pixel Sensors (MAPS). A test sensor with a pixel size of 50x50 um2 has been fabricated in July 2007. The simulation of the physical…
In experiment with the SND detector at VEPP-2M $e^+e^-$ collider the $e^+e^-\to\eta\gamma$ cross section was measured in the energy range $E$=0.60--1.38 GeV with the integrated luminosity of 27.8 pb$^{-1}$. The measured cross section is…
The process $e^+e^- \to \pi^0\gamma$ has been studied in the experiment with the SND detector at the VEPP-2M $e^+e^-$ collider. The $e^+e^- \to \pi^0\gamma$ cross section has been measured in the center-of-mass energy range from 0.60 to…