Related papers: Electromagnetic calorimeter time measurement appli…
The $e^+e^-\to K^+K^-$ cross section is measured in the center-of-mass energy range $1.05-2.00$ GeV at the SND detector. The measurement is based on data with an integrated luminosity of 35 pb$^{-1}$ collected at the VEPP-2000…
We present a new publicly available dataset that contains simulated data of a novel calorimeter to be installed at the CERN Large Hadron Collider. This detector will have more than six-million channels with each channel capable of position,…
Calibration of the three layer NaI(Tl) spherical calorimeter of the SND detector using electron -- positron scattering events is described. Energy resolution of $5 % (FWHM/2.36)$ for 500 MeV photons was achieved.
This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is…
The fine-sampling electromagnetic calorimeter prototype has been experimentally tested using the 1-19 GeV/c tagged beams of negatively charged particles at the U70 accelerator at IHEP, Protvino. The energy resolution measured by electrons…
Regular data taking started at the VEPP2000 $e^+ e^-$ Collider with CMD3 and SND detectors. Energy scan for center-of-mass energy from 1 GeV to 2 GeV has been performed with about 20 pb$^{-1}$ per detector. We present first preliminary…
We study the photon detection efficiency and position resolution of the electromagnetic calorimeter (EMC) of the BESIII detector. The control samples of the initial-state-radiation (ISR) process of $e^+e^-\rightarrow \gamma \mu^+\mu^-$ at…
In the experiment to study the e+e->n+anti n process at the VEPP-2000 $e^+e^-$ collider, the ratio |GE|/|GM| of the neutron timelike electric and magnetic form factors has been measured. The experiment was carried out with the SND detector…
A readout electronic with high time and energy resolution performance is designed for the SDD (Silicon Drift Detector) signals readout, which is aimed for X-ray pulsar based navigation (XNAV). For time measurement, the input signal is fed…
Shashlyk-type electromagnetic calorimeter (ECal) of the Multi-Purpose Detector at heavy-ion NICA collider is optimized to provide precise spatial and energy measurements for photons and electrons in the energy range from about 40 MeV to 2-3…
The cross section of the process $e^+e^- \to K^+K^-$ was measured in the energy range $\sqrt{s}$ = 1.04--1.38 GeV in the SND experiment at the VEPP-2M $e^+e^-$ collider. The measured cross section is described by the model of vector meson…
The subject of the thesis is the study of electromagnetic transitions in charmonium with PANDA. The possible registration of the $h_c$ state in charmonium, observed recently by the E760 and E835 Fermilab experiments, is used for…
The $e^+ e^- \to K^0_{S}K^0_{L}$ and $e^+ e^- \to K^{-}K^{+}$ cross sections have been measured in the center-of-mass energy range 1004--1060 MeV for 25 energy points with about 2$\div$3\% systematic uncertainties. The analysis is based on…
The cross section for the $e^+e^-\to K_SK_L$ process is measured in the center-of-mass energy range from 1000 MeV to 1100 MeV in the experiment with the SND detector at the VEPP-2000 $e^+e^-$ collider. The measurement is carried out in the…
New results of the e+e- -> pi+pi-, K+K-, K_SK_L, pi0/gamma, eta0/gamma processes cross section measurements are presented. The results are based on the 30 pb^-1 data, accumulated by SND detector at VEPP-2M e+e- collider in the energy range…
Quantitative electron magnetic circular dichroism (EMCD) in transmission electron microscopy (TEM) enables the measurement of magnetic moments with elemental and atomic site sensitivity, but its practical application is fundamentally…
We describe the design and performance the calorimeter systems used in the ECCE detector design to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The…
The calorimeter system of LHCb is subdivided into four sub-detectors which ensure its longitudinal segmentation: a Scintillator Pad Detector (SPD) followed by a Preshower (PS) and then an electromagnetic (ECAL) an hadronic (HCAL)…
The operation and performance of the Compact Muon Solenoid (CMS) electromagnetic calorimeter (ECAL) are presented, based on data collected in pp collisions at $\sqrt{s}$ = 13 TeV at the CERN LHC, in the years from 2015 to 2018 (LHC Run 2),…
In the experiment with the SND detector at the VEPP-2000 $e^+e^-$ collider the cross section for the process $e^+e^-\to\eta\pi^+\pi^-$ has been measured in the center-of-mass energy range from 1.22 to 2.00 GeV. Obtained results are in…