English
Related papers

Related papers: Large-scale detector testing for the GAPS Si(Li) T…

200 papers

The production of flexible and robust thermal neutron detectors with improved properties as compared to the commercial ZnS:Ag based phosphors is here pursued, exploiting a siloxane binder, whose intrinsic properties as related to the…

Instrumentation and Detectors · Physics 2018-08-30 S. M. Carturan , M. Vesco , I. Bonesso , A. Quaranta , G. Maggioni , L. Stevanato , E. Zanazzi , T. Marchi , D. Fabris , M. Cinausero , F. Gramegna

New generation high-energy physics experiments demand high precision tracking and accurate measurements of a large number of particles produced in the collisions of lementary particles and heavy-ions. Silicon-tungsten (Si-W) calorimeters…

A novel modular high-resolution charged-particle tracking detector design using $250\mu m$ diameter, round, scintillating fibers and SiPM arrays for readout is presented. The fiber modules consist of 8 layers of 128 fibers, mechanically sta…

Instrumentation and Detectors · Physics 2008-11-26 Henning Gast , Thomas Kirn , Gregorio Roper Yearwood , Stefan Schael

Low mass nuclear recoil dark matter and coherent-elastic-neutrino-nucleus-scattering (CENNS) searches confront similar challenges in choosing ultra-low threshold and large-mass detectors. We report experimental results from the…

The Sub-Electron-Noise Skipper CCD Experimental Instrument (SENSEI) uses the recently developed Skipper-CCD technology to search for electron recoils from the interaction of sub-GeV dark matter particles with electrons in silicon. We report…

Research and development on alternative thermal neutron detection technologies and methods are nowadays needed as a possible replacement of 3He-based ones. Commercial solid state silicon detectors, coupled with neutron converter layers…

Instrumentation and Detectors · Physics 2017-03-07 Sergio Lo Meo , Luigi Cosentino , Paolo Bartolomei , Paolo Finocchiaro

Searches for weakly interacting massive particles(WIMP) can be based on the dete ction of nuclear recoil energy in CsI(Tl) crystals. We demonstrate that low energy gamma rays down to few keV is detected with CsI(Tl) crystal detector. A…

Instrumentation and Detectors · Physics 2019-08-17 H. J. Kim , H. J. Ahn , S. K. Kim , E. Won , T. Y. Kim , Y. D. Kim , M. H. Lee , J. S. Chai , J. H. Ha

The DarkSide-20k collaboration is preparing to equip 20 m^2 of SiPMs working in liquid argon at 86 K for the direct search of WIMPs. The collaboration had to solve many technological aspects, such as the development of SiPM optimized for…

Instrumentation and Methods for Astrophysics · Physics 2019-04-02 I. Kochanek

The EDELWEISS experiment used in 2001 a 320g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane for direct WIMP detection. This detector presents an increase of more…

A future compact and modular X and gamma-ray spectrometer (XGS) has been designed and a series of prototypes have been developed and tested. The experiment envisages the use of CsI scintillator bars read out at both ends by single-cell 25…

The ATLAS experiment, at the Large Hadron Collider, will incorporate discrete, high-resolution tracking sub-systems in the form of segmented silicon detectors with 40MHz radiation-hard readout electronics. In the region closest to the pp…

High Energy Physics - Experiment · Physics 2007-05-23 John Richardson , representing the ATLAS Pixel Project

Current interferometric gravitational wave detectors use the combination of quasi-monochromatic, continuous-wave laser light at 1064 nm and fused silica test masses at room temperature. Detectors of the third generation, such as the…

A testbeam telescope, based on ATLAS IBL silicon pixel modules, has been built. It comprises six planes of planar silicon sensors with 250 x 50 um^2 pitch, read out by ATLAS FE-I4 chips. In the CERN SPS H8 beamline (180 GeV pi+) a…

The last years have seen the first cryogenic detectors to be proposed for usage on balloon-borne missions. In such missions, the instrument will be exposed to the high radiation environment of the upper atmosphere. This radiation can induce…

Instrumentation and Detectors · Physics 2025-10-23 Merlin Kole , Kasun Wimalasena , Richard Gorby , Torsten Diesel , Zachary Greenberg , Fabian Kislat

Scintillators have long been known as radiation detectors and are still used in various applications. Recently, scintillators containing $^6$Li have been developed as neutron detectors and have attracted attention. $^6$Li absorbs thermal…

Instrumentation and Detectors · Physics 2023-01-09 Takashi Iida , Masao Yoshino , Kei Kamada , Rei Sasaki , Ryuga Yajima

Cathode electrodes of the Si(Li) detector elements of the SIXA X-ray spectrometer array are formed by gold-palladium alloy contact layers. The equivalent thickness of gold in one element was measured by observing the characteristic L-shell…

Instrumentation and Detectors · Physics 2009-10-30 T. Tikkanen , K. Hamalainen , S. Huotari

During the three years long assessment phase of the LOFT mission, candidate to the M3 launch opportunity of the ESA Cosmic Vision programme, we estimated and measured the radiation damage of the silicon drift detectors (SDDs) of the…

Instrumentation and Methods for Astrophysics · Physics 2019-08-15 E. Del Monte , P. Azzarello , E. Bozzo , S. Bugiel , S. Diebold , Y. Evangelista , E. Kendziorra , F. Muleri , E. Perinati , A. Rachevski , G. Zampa , N. Zampa , M. Feroci , M. Pohl , A. Santangelo , A. Vacchi

The presented results are part of a feasibility study of a Super- heated Superconducting Granule (SSG) device for weakly interacting massive particles (WIMPs) detection. The sensitivity of SSG to nuclear recoils has been explored…

Astrophysics · Physics 2009-09-25 A. Gabutti

In beam test experiments have been carried out for particle identification using digital pulse shape analysis in a 500~$\mu$m thick Neutron Transmutation Doped (nTD) silicon detector with an indigenously developed FPGA based 12 bit…

Instrumentation and Detectors · Physics 2018-05-09 K. Mahata , A. Shrivastava , J. A. Gore , S. K. Pandit , V. V. Parkar , K. Ramachandran , A. Kumar , S. Gupta , P. Patale

Among the top priorities for high-energy astronomy in the coming decade are sensitive surveys in the hard X-ray/soft \gamma-ray (10-600 keV) and medium-energy \gamma-ray (0.2-80 MeV) bands. Historically, observations in the soft and medium…

Instrumentation and Methods for Astrophysics · Physics 2013-02-26 Alexei Ulyanov , Lorraine Hanlon , Sheila McBreen , Suzanne Foley , David Byrne