English
Related papers

Related papers: A Sub-Electron-Noise Multi-Channel Cryogenic Skipp…

200 papers

The aim of this study is to design and evaluate a simple free running Analog-Digital Converter (ADC) based on the Field Programmable Gate Array (FPGA) device to accomplish the energy and position readout of the silicon photomultiplier…

Instrumentation and Detectors · Physics 2021-08-19 Cong Ma , Xue Dong , Li Yu , Wubin Wang , Xiaokun Zhao , Xing Li , Zhenqing Huang , Guocheng Wu , Lei Lu , Hansheng Chen

We describe a novel GaAs/AlGaAs double-quantum-well device for the infrared photon detection, called Charge-Sensitive Infrared Phototransistor (CSIP). The principle of CSIP detector is the photo-excitation of an intersubband transition in a…

Instrumentation and Methods for Astrophysics · Physics 2015-05-14 Y. Doi , Z. Wang , T. Ueda , P. Nickels , S. Komiyama , M. Patrashin , I. Hosako , S. Matsuura , M. Shirahata , Y. Sawayama , M. Kawada

Scandium-doped aluminum nitride has recently emerged as a promising material for quantum photonic integrated circuits (PICs) due to its unique combination of strong second-order nonlinearity, ferroelectricity, piezoelectricity, and…

For the upgrade of the inner tracker of the BESIII spectrometer, planned for 2018, a lightweight tracker based on an innovative Cylindrical Gas Electron Multiplier (CGEM) detector is now under development. The analogue readout of the CGEM…

All-digital millimeter-wave (mmWave) massive multi-user multiple-input multiple-output (MU-MIMO) receivers enable extreme data rates but require high power consumption. In order to reduce power consumption, this paper presents the first…

Signal Processing · Electrical Eng. & Systems 2021-07-26 Oscar Castañeda , Zachariah Boynton , Seyed Hadi Mirfarshbafan , Shimin Huang , Jamie C. Ye , Alyosha Molnar , Christoph Studer

To face the higher levels of radiation due to the 10-fold increase in integrated luminosity during the High-Luminosity LHC, the CMS detector will replace the current Calorimeter Endcap (CE) using the High-Granularity Calorimeter (HGCAL)…

Accurate temperature regulation is critical for amperometric DNA analysis to achieve high fidelity, reliability, and throughput. In this work, a 9x6 cell array of mixed-signal CMOS distributed temperature regulators for on-CMOS multi-modal…

Systems and Control · Electrical Eng. & Systems 2022-08-02 Hamed M. Jafari , Xilin Liu , Roman Genov

Future strategic X-ray astronomy missions will require unprecedentedly sensitive wide-field imagers providing high frame rates, low readout noise and excellent soft energy response. To meet these needs, our team is employing a multi-pronged…

The Front End Driver, FED, is a 9U 400mm VME64x card designed for reading out the Compact Muon Solenoid, CMS, silicon tracker signals transmitted by the APV25 analogue pipeline Application Specific Integrated Circuits. The FED receives the…

Large power consumption of silicon CMOS electronics is a challenge in very-large-scale integrated circuits and a major roadblock to fault-tolerant quantum computation. Matching the power dissipation of Si-MOSFETs to the thermal budget at…

Recent progress in the 4H-silicon-carbide-on-insulator (4H-SiCOI) platform has resulted in the demonstration of essential building blocks such as low-loss waveguides and microresonators. In this work, we add tunability to the 4H-SiCOI…

Optics · Physics 2025-06-19 Wenhan Sun , Ruixuan Wang , Jingwei Li , Haipeng Zhang , Zhensheng Jia , Qing Li

Fault-tolerant spin-based quantum computers will require fast and accurate qubit readout. This can be achieved using radio-frequency reflectometry given sufficient sensitivity to the change in quantum capacitance associated with the qubit…

Amorphous silicon carbide (a-SiC) has emerged as a compelling candidate for applications in integrated photonics, known for its high refractive index, high optical quality, high thermo-optic coefficient, and strong third-order…

Low-noise temperature measurements at frequencies in the milli-Hertz range are needed in the LISA and LISA PathFinder (LPF). The required temperature stability for LISA is around 10 uK/sqrt(Hz) at frequencies down to 0.1 mHz. In this paper…

General Relativity and Quantum Cosmology · Physics 2010-02-25 J. Sanjuan , A. Lobo , J. Ramos-Castro

We present RF-ICE, a novel readout platform for microwave kinetic inductance detectors (MKIDs), optimized for use on millimeter-wavelength telescopes. The RF-ICE system extends ICE, a versatile, mature signal processing platform currently…

Instrumentation and Methods for Astrophysics · Physics 2023-10-12 M. Rouble , G. Smecher , A. Anderson , P. S. Barry , K. Dibert , M. Dobbs , K. S. Karkare , J. Montgomery

A microwave SQUID multiplexer ($\mu$MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design in a 1820-channel multiplexer…

We developed CdTe double-sided strip detectors (DSDs or cross strip detectors) and evaluated their spectral and imaging performance for hard X-rays and gamma-rays. Though the double-sided strip configuration is suitable for imagers with a…

Nano-electro-opto-mechanical systems enable the synergistic coexistence of electrical, mechanical, and optical signals on a chip to realize new functions. Most of the technology platforms proposed for the fabrication of these systems so far…

The realization of large-scale photonic circuit for quantum optics experiments at telecom wavelengths requires an increasing number of integrated detectors. Superconductive nanowire single photon detectors (SNSPDs) can be easily integrated…

‹ Prev 1 8 9 10 Next ›