Related papers: Performance of TES X-Ray Microcalorimeters Designe…
If a hypothetical elementary particle called an axion exists, to solve the strong CP problem, a 57Fe nucleus in the solar core could emit a 14.4-keV monochromatic axion through the M1 transition. If such axions are once more transformed…
Transition edge sensors (TESs) are superconducting energy-resolving microcalorimeters that have demonstrated low background rates as well as quantum efficiencies close to unity for photons at optical and near-infrared wavelengths. This…
Experimental searches for axions or dark photons that couple to the standard model photon require photosensors with low noise, broadband sensitivity, and near zero backgrounds. Here, we introduce an experimental architecture, in which a…
We have searched for 14.4 keV solar axions or more general axion-like particles (ALPs), that may be emitted in the M1 nuclear transition of 57Fe, by using the axion-to-photon conversion in the CERN Axion Solar Telescope (CAST) with…
The Transition Edge Sensor is extremely sensitive to the change of temperature, combined with the high-Z metal of a certain thickness, it can realize the high energy resolution measurement of particles such as X-rays. X-rays with energies…
The purpose of this paper is to assess the feasibility of axion detection by X-ray spectroscopy of the sun. We review the theory of axion-photon mode conversion with special attention to axions emitted in the 14.4 keV M1 decay of 57Fe at…
The CERN Axion Solar Telescope (CAST) is searching for solar axions using the 9.0 T strong and 9.26 m long transverse magnetic field of a twin aperture LHC test magnet, where axions could be converted into X-rays via reverse Primakoff…
A search for resonant absorbtion of 14.4 keV solar axions by $^{57}$Fe target was performed. The Si(Li) detector placed inside the low-background setup was used to detect the $\gamma$-quanta appearing in the deexcitation of 14.4 keV nuclear…
Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20 keV energy range. We are building a TES-based instrument for the…
The existence of the axion is a unique solution for the strong CP problem, and the axion is one of the most promising candidates of the dark matter. Investigating Solar Axion by Iron-57 (ISAI) is being prepared as a complemented table-top…
A new experimental scheme is proposed to search for almost monochromatic solar axions, whose existence has not been discussed heretofore. The axions would be produced when thermally excited $^{57}$Fe in the sun relaxes to its ground state…
We investigate the possibility of detecting 14.4 keV and 9.4 keV solar axions and axion-like particles that could be produced in the M1 nuclear transitions of $^{57}$Fe and $^{83}$Kr, respectively. To do so, we used data from soft X-ray…
The possibility of detection of 5.5 MeV and 14.4 keV solar axions by observing axion-induced nuclear and atomic transitions is investigated. The presence of nuclear transitions between spin-orbit partners can be manifested by the subsequent…
The state-of-the-art technology of X-ray microcalorimeters based on superconducting transition edge sensors (TESs), for applications in astrophysics and particle physics, is reviewed. We will show the advance in understanding the detector…
Energy resolution is an important figure of merit for TES microcalorimeter. We propose a laser system to measure the energy resolution of TES microcalorimeter with a 1550 nm laser source. Compared to method that characterizes the…
Large arrays of superconducting transition-edge sensor (TES) microcalorimeters are becoming the key technology for future space-based X-ray observatories and ground-based experiments in the fields of astrophysics, laboratory astrophysics,…
Transition-edge sensors (TESs) are capable of highly accurate single particle energy measurement. TESs have been used for a wide range of photon detection applications, particularly in astronomy, but very little consideration has been given…
We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m squared, AuBi…
The application of cryogenic single photon detectors has found great use in high precision particle physics experiments such as ALPS (Any Light Particle Search) II, which implements it for fundamental studies to search for new particles.…
Transition Edge Sensors (TES) are superconducting microcalorimeters that can be used for single-photon detection with extremely low backgrounds. When they are within their superconducting transition region, small temperature fluctuations -…