Related papers: Generalized Method for the Optimization of Pulse S…
A first comparison has been made between the pulse-shape discrimination characteristics of a novel $^{4}$He-based pressurized scintillation detector and a NE-213 liquid-scintillator reference detector using an Am/Be mixed-field neutron and…
A new and simple technique has been developed using plastic scintillator detectors for gamma ray and cosmic ray spectroscopy without single channel analyzer (SCA) or multichannel analyzer (MCA). In these experiments only a leading edge…
The basic principles of detection of fast neutrons with liquid scintillator detectors are reviewed, together with a real example in the form of the Neutron Wall array. Two of the challenges in neutron detection, discrimination of neutrons…
New experimental research programs in the field of neutrino physics are calling for new detectors with large masses, high energy resolution and good background rejection capabilities. This paper presents a novel hybrid organic/inorganic…
Large-scale particle physics detectors often contain millions of repeated components, making precise and efficient quality control essential. We have developed a semiautomatic system for dimensional screening of 1 cm$^3$ plastic…
For an empirical signed measure $\mu = \frac{1}{N} \left(\sum_{i=1}^P \delta_{x_i} - \sum_{i=1}^M \delta_{y_i}\right)$, particle annihilation (PA) removes $N_A$ particles from both $\{x_i\}_{i=1}^P$ and $\{y_i\}_{i=1}^M$ simultaneously,…
Pulsars have been primarily detected by their narrow pulses or periodicity in time domain data. Interferometric surveys for pulsars are challenging due to the trade-off between beam sensitivity and beam size and the corresponding tradeoff…
In this work, we present results for discrimination of neutron and $\gamma$ events using a plastic scintillator detector with pulse shape discrimination capabilities. Machine learning (ML) algorithms are used to improve the discriminatory…
Previous RGB-D salient object detection (SOD) methods have widely adopted deep learning tools to automatically strike a trade-off between RGB and D (depth), whose key rationale is to take full advantage of their complementary nature, aiming…
Background: Spectral shaping is a computed tomography (CT) dose optimization technique that adjusts source voltage and filtration to reduce patient radiation exposure without compromising image quality. Traditionally, radiation dose has…
Proportional scintillation counters (PSCs), both single- and dual-phase, can measure the scintillation (S1) and ionization (S2) channels from particle interactions within the detector volume. The signal obtained from these detectors depends…
Plastic scintillation detectors are increasingly used to measure dose distributions in the context of radiotherapy treatments. Their water-equivalence, real-time response and high spatial resolution distinguish them from traditional…
We propose a hierarchical Bayesian model and state-of-art Monte Carlo sampling method to solve the unfolding problem, i.e., to estimate the spectrum of an unknown neutron source from the data detected by an organic scintillator. Inferring…
Scintillators capable of detecting both neutrons and gamma-rays have generated considerable interest. In particular, the use of such scintillators with silicon photomultipliers (SiPMs) enables low-power and compact-geometry applications.…
A novel composite, scintillating material intended for neutron detection and composed of small (1.5 mm) cubes of KG2-type lithium glass embedded in a matrix of scintillating plastic has been developed in the form of a 2.2 in.-diameter, 3.1…
This work reports on the performance of a novel neutron-sensitive scintillating detector fabricated using Fused-Deposition Modelling (FDM) additive manufacturing. FDM is a cost-effective 3D-printing method employing flexible plastic…
We propose an analytical framework based on stochastic geometry (SG) formulations to estimate a radar's detection performance under generalized discrete clutter conditions. We model the spatial distribution of discrete clutter scatterers as…
The light output, $\alpha/\beta$ ratio, and pulse shape have been investigated at $-25^\circ$ C with PbWO$_4$ crystal scintillators undoped, and doped by F, Eu, Mo, Gd and S. The fast $0.01-0.06 \mu$s and middle $0.1-0.5 \mu$s components of…
A novel data-processing method was developed to facilitate scintillation detector characterization. Combined with fan-beam calibration, this method can be used to quickly and conveniently calibrate gamma-ray detectors for SPECT, PET,…
The publicly accessible dataset includes neutron and gamma-ray pulse signals for conducting pulse shape discrimination experiments. Several traditional and recently proposed pulse shape discrimination algorithms are utilized to evaluate the…