English
Related papers

Related papers: Precision measurement of an electron pump at 2 GHz

200 papers

Bioimpedance measurements are a non-invasive method to determine the composition of organic tissue. For measuring the complex bioimpedance between two electrodes, an alternating current with a constant amplitude is injected into the tissue.…

Instrumentation and Detectors · Physics 2020-08-07 Roman Kusche , Steffen Kaufmann , Martin Ryschka

We report a method to derive the potential barrier profile shape in a dynamic quantum dot and show the loading statistics, and hence accuracy of electron transfer, depend significantly on the shape of the barrier. This method takes a…

Mesoscale and Nanoscale Physics · Physics 2019-07-22 Nathan Johnson , Gento Yamahata , Akira Fujiwara

A simple, low-cost millimeter-wave (70 GHz) interferometer with a phase accuracy better than plus or minur 2 degrees, and a response time of 10 ns is described. The simplicity of this interferometer makes it ideal for measurement of…

Instrumentation and Detectors · Physics 2020-02-27 M. Gilmore , W. Gekelman , K. Reiling , W. A. Peebles

We present a prescription for generating pure spin current or spin selective current, based on adiabatic quantum pumping in a tight-binding model of a one dimensional conductor. A formula for the instantaneous pumped current is derived…

Mesoscale and Nanoscale Physics · Physics 2007-05-23 Sungjun Kim , Kunal K. Das , Ari Mizel

This study demonstrates the feasibility of using smaller capillary emitters to achieve higher specific impulse ($I_\text{sp}$) in electrospray propulsion. Four ionic liquids were characterized using capillary emitters with tip diameters…

Fluid Dynamics · Physics 2026-04-07 Manel Caballero-Pérez , Marc Galobardes-Esteban , Manuel Gamero-Castaño

A circuit-simulation-based method is used to determine the thermally-induced bit error rate of superconducting logic circuits. Simulations are used to evaluate the multidimensional Gaussian integral across noise current sources attached to…

Applied Physics · Physics 2023-06-14 Quentin Herr , Alex Braun , Andrew Brownfield , Ed Rudman , Dan Dosch , Trent Josephsen , Anna Herr

In this study, using only a single pulse, pump-probe measurement with a large time window of more than 100 ps is implemented. A commercial grating is used to encode a time window of ~ 56 ps in a single pulse; therefore, there is no need for…

Optics · Physics 2023-12-29 Tianchen Yu , Junyi Yang , Zhongguo Li , Xingzhi Wu , Yu Fang , Yong Yang , Yinglin Song

An AC susceptometer operating in the range of 10 Hz to 100 kHz and at room temperature is designed, built, calibrated and used to characterize the magnetic behaviour of coated magnetic nanoparticles. Other weakly magnetic materials (in…

Instrumentation and Detectors · Physics 2013-12-18 M. Alderighi , G. Bevilacqua , V. Biancalana , Y. Dancheva , A. Khanbekyan , L. Moi

Experimental characterization of blood flow in living organisms is crucial for understanding the development and function of cardiovascular systems, but there have been no techniques reported for snapshot imaging of thick samples in large…

We present a method for measurements of electric dipole moments on (sub)-mm size (basalt) particles levitated in an acoustic trap and centered within a plate capacitor. If an electric field is applied the particles oscillate with specific…

Instrumentation and Detectors · Physics 2022-02-07 F. Chioma Onyeagusi , Jens Teiser , Niclas Schneider , Gerhard Wurm

We propose a method to perform accurate and fast charge pumping in superconducting nanocircuits. Combining topological properties and quantum control techniques based on shortcuts to adiabaticity, we show that it is theoretically possible…

Mesoscale and Nanoscale Physics · Physics 2019-12-24 Paolo Andrea Erdman , Fabio Taddei , Joonas T. Peltonen , Rosario Fazio , Jukka P. Pekola

This paper describes the realization of a two terminal-pair digital impedance bridge and the test measurements performed with it. The bridge, with a very simple architecture, is based on a commercial two-channel digital signal synthesizer…

Instrumentation and Detectors · Physics 2014-08-13 Luca Callegaro , Vincenzo D'Elia , Marian Kampik , Dan Bee Kim , Massimo Ortolano , Faranak Pourdanesh

We present a measurement of the hydrogen $2$S$_{1/2}-8$D$_{5/2}$ transition performed with a cryogenic atomic beam. The measured resonance frequency is $\nu=770649561570.9(2.0)$ kHz, which corresponds to a relative uncertainty of…

Atomic Physics · Physics 2022-01-26 A. D. Brandt , S. F. Cooper , C. Rasor , Z. Burkley , D. C. Yost , A. Matveev

We describe the construction and operation of a segmented linear Paul trap, fabricated in printed-circuit-board technology with an electrode segment width of 500 microns. We prove the applicability of this technology to reliable ion…

Quantum Physics · Physics 2007-11-20 G. Huber , T. Deuschle , W. Schnitzler , R. Reichle , K. Singer , F. Schmidt-Kaler

Many modern electronic devices utilize linear Hall sensors to measure current and the magnetic field, as well as to perform switching and latching operations. Smartphones, laptops, and e-readers all work with very low (sub-mA) currents. To…

Instrumentation and Detectors · Physics 2018-02-09 Yossi Sharon , Bagrat Khachatryan , Dima Cheskis

We report a highly sensitive all-fiber hydrogen sensor based on continuous-wave stimulated Raman gain spectroscopy with a hollow-core photonic crystal fiber operating around 1550 nm. A pump-probe configuration is used, in which the…

Instrumentation and Detectors · Physics 2016-11-30 Fan Yang , Wei Jin

This proceeding summarizes recent measurements of electroweak boson and diboson production. The results, based on data from LHC Run 2 at $\sqrt{s}=13\,\mathrm{TeV}$ and Run 3 at $\sqrt{s}=13.6\,\mathrm{TeV}$, probe the Standard Model with…

High Energy Physics - Experiment · Physics 2025-07-16 Francesco Giuli

A low noise constant current source used for measuring the $1/f$ noise in disordered systems in ohmic as well as non-ohmic regime is described. The source can supply low noise constant current starting from as low as 1 $\mu$A to a few tens…

Disordered Systems and Neural Networks · Physics 2015-05-20 D. Talukdar , R. K. Chakraborty , Suvendu Bose , K. K. Bardhan

This paper describes the results of the most recent measurement of the permanent electric dipole moment (EDM) of neutral $^{199}$Hg atoms. Fused silica vapor cells containing enriched $^{199}$Hg are arranged in a stack in a common magnetic…

Atomic Physics · Physics 2017-08-21 B. Graner , Y. Chen , E. G. Lindahl , B. R. Heckel

The state of charge (SoC) and the rate of charging/discharging current are the vital parameters associated with a battery by which its accurate runtime can be estimated. This paper aims to design a controller which comprises of a…

Signal Processing · Electrical Eng. & Systems 2020-05-26 P. Dinesh , K. Kumar Teja , Shashank Singh , Selvan M. P. , Moorthi S
‹ Prev 1 8 9 10 Next ›