English
Related papers

Related papers: Low-energy Calibration of XENON1T with an Internal…

200 papers

We present the preparation and measurement of the radioactive isotope $\rm ^{37}Ar$, which was produced using thermal neutrons from a reactor, as a calibration source for liquid xenon time projection chambers. $\rm ^{37}Ar$ is a low-energy…

Instrumentation and Detectors · Physics 2026-03-12 Xu-Nan Guo , Chang Cai , Fei Gao , Yang Lei , Kai-Hang Li , Chun-Lei Su , Ze-Peng Wu , Xiang Xiao , Ling-Feng Xie , Yi-Fei Zhao , Xiao-Peng Zhou

We describe the first demonstration of a sub-keV electron recoil energy threshold in a dual-phase liquid argon time projection chamber. This is an important step in an effort to develop a detector capable of identifying the ionization…

Instrumentation and Methods for Astrophysics · Physics 2013-07-23 S. Sangiorgio , T. H. Joshi , A. Bernstein , J. Coleman , M. Foxe , C. Hagmann , I. Jovanovic , K. Kazkaz , K. Mavrokoridis , V. Mozin , S. Pereverzev , P. Sorensen

Characterizing low-energy, keV-range nuclear recoils near the detector threshold is one of the major challenges for large direct dark matter detectors. To that end, we have successfully used a Yttrium-Beryllium photoneutron source that…

Instrumentation and Detectors · Physics 2026-05-01 XENON Collaboration , E. Aprile , J. Aalbers , K. Abe , S. Ahmed Maouloud , L. Althueser , B. Andrieu , E. Angelino , D. Antón Martin , F. Arneodo , L. Baudis , M. Bazyk , L. Bellagamba , R. Biondi , A. Bismark , K. Boese , A. Brown , G. Bruno , R. Budnik , C. Cai , C. Capelli , J. M. R. Cardoso , A. P. Cimental Chávez , A. P. Colijn , J. Conrad , J. J. Cuenca-García , V. D'Andrea , L. C. Daniel Garcia , M. P. Decowski , A. Deisting , C. Di Donato , P. Di Gangi , S. Diglio , K. Eitel , S. el Morabit , A. Elykov , A. D. Ferella , C. Ferrari , H. Fischer , T. Flehmke , M. Flierman , W. Fulgione , C. Fuselli , P. Gaemers , R. Gaior , M. Galloway , F. Gao , S. Ghosh , R. Giacomobono , R. Glade-Beucke , L. Grandi , J. Grigat , H. Guan , M. Guida , P. Gyorgy , R. Hammann , A. Higuera , C. Hils , L. Hoetzsch , N. F. Hood , M. Iacovacci , Y. Itow , J. Jakob , F. Joerg , Y. Kaminaga , M. Kara , P. Kavrigin , S. Kazama , P. Kharbanda , M. Kobayashi , D. Koke , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Li , S. Liang , Z. Liang , Y. T. Lin , S. Lindemann , M. Lindner , K. Liu , M. Liu , J. Loizeau , F. Lombardi , J. Long , J. A. M. Lopes , T. Luce , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , E. Masson , S. Mastroianni , A. Melchiorre , J. Merz , M. Messina , A. Michael , K. Miuchi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , J. Müller , K. Ni , U. Oberlack , B. Paetsch , Y. Pan , Q. Pellegrini , R. Peres , C. Peters , J. Pienaar , M. Pierre , G. Plante , T. R. Pollmann , L. Principe , J. Qi , J. Qin , D. Ramírez García , M. Rajado , R. Singh , L. Sanchez , J. M. F. dos Santos , I. Sarnoff , G. Sartorelli , J. Schreiner , P. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , S. Shi , J. Shi , M. Silva , H. Simgen , C. Szyszka , A. Takeda , Y. Takeuchi , P. L. Tan , D. Thers , F. Toschi , G. Trinchero , C. D. Tunnell , F. Tönnies , K. Valerius , S. Vecchi , S. Vetter , F. I. Villazon Solar , G. Volta , C. Weinheimer , M. Weiss , D. Wenz , C. Wittweg , V. H. S. Wu , Y. Xing , D. Xu , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , M. Zhong

We calibrate a two-phase xenon detector at 0.27 keV in the charge channel and at 2.8 keV in both the light and charge channels using a $^{37}$Ar source that is directly released into the detector. We map the light and charge yields as a…

Instrumentation and Detectors · Physics 2017-09-13 E. M. Boulton , E. Bernard , N. Destefano , B. N. V. Edwards , M. Gai , S. A. Hertel , M. Horn , N. A. Larsen , B. P. Tennyson , C. Wahl , D. N. McKinsey

We present the results of the first experimental study of ionization yield of electron recoils with energies below 100 keV produced in liquid xenon by the isotopes: 37Ar, 83mKr, 241Am, 129Xe, 131Xe. It is confirmed by a direct measurement…

For the first time, a small dual-phase (liquid/gas) xenon time projection chamber was equipped with a top array of silicon photomultipliers for light and charge readout. Here we describe the instrument in detail, as well as the data…

Instrumentation and Methods for Astrophysics · Physics 2021-11-02 L. Baudis , Y. Biondi , M. Galloway , F. Girard , S. Hochrein , S. Reichard , P. Sanchez-Lucas , K. Thieme , J. Wulf

A small-scale, two-phase (liquid/gas) xenon time projection chamber (Xurich II) was designed, constructed and is under operation at the University of Zurich. Its main purpose is to investigate the microphysics of particle interactions in…

Instrumentation and Methods for Astrophysics · Physics 2018-05-23 Laura Baudis , Yanina Biondi , Chiara Capelli , Michelle Galloway , Shingo Kazama , Alexander Kish , Payam Pakarha , Francesco Piastra , Julien Wulf

We report on the response of liquid xenon to low energy electronic recoils below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method based on…

Instrumentation and Methods for Astrophysics · Physics 2018-05-30 E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , F. D. Amaro , M. Anthony , F. Arneodo , P. Barrow , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , L. Bütikofer , J. Calvén , J. M. R. Cardoso , M. Cervantes , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , C. Geis , L. W. Goetzke , L. Grandi , Z. Greene , C. Grignon , C. Hasterok , E. Hogenbirk , R. Itay , B. Kaminsky , S. Kazama , G. Kessler , A. Kish , H. Landsman , R. F. Lang , D. Lellouch , L. Levinson , Q. Lin , S. Lindemann , M. Lindner , F. Lombardi , J. A. M. Lopes , A. Manfredini , I. Maris , T. Marrodán Undagoitia , J. Masbou , F. V. Massoli , D. Masson , D. Mayani , M. Messina , K. Micheneau , A. Molinario , K. Morå , M. Murra , J. Naganoma , K. Ni , U. Oberlack , P. Pakarha , B. Pelssers , R. Persiani , F. Piastra , J. Pienaar , V. Pizzella , M. -C. Piro , G. Plante , N. Priel , D. Ramírez García , L. Rauch , S. Reichard , C. Reuter , A. Rizzo , N. Rupp , R. Saldanha , J. M. F. dos Santos , G. Sartorelli , M. Scheibelhut , S. Schindler , J. Schreiner , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , M. v. Sivers , A. Stein , D. Thers , A. Tiseni , G. Trinchero , C. Tunnell , M. Vargas , H. Wang , Z. Wang , Y. Wei , C. Weinheimer , J. Wulf , J. Ye , Y. Zhang

Low-background liquid xenon detectors are utilized in the investigation of rare events, including dark matter and neutrinoless double beta decay. For their calibration, gaseous $^{220}$Rn can be used. After being introduced into the xenon,…

Instrumentation and Detectors · Physics 2023-11-15 Florian Jörg , Shengchao Li , Jochen Schreiner , Hardy Simgen , Rafael F. Lang

A dual-phase xenon time-projection chamber was built at Nikhef in Amsterdam as a direct dark matter detection R&D facility. In this paper, the setup is presented and the first results from a calibration with a $^{22}$Na gamma-ray source are…

Instrumentation and Detectors · Physics 2016-11-23 E. Hogenbirk , J. Aalbers , M. Bader , P. A. Breur , A. Brown , M. P. Decowski , C. Tunnell , R. Walet , A. P. Colijn

We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0\nu\beta\beta$) that will use a 5-tonne, monolithic liquid…

Instrumentation and Detectors · Physics 2022-08-03 B. G. Lenardo , C. A. Hardy , R. H. M. Tsang , J. C. Nzobadila Ondze , A. Piepke , S. Triambak , A. Jamil , G. Adhikari , S. Al Kharusi , E. Angelico , I. J. Arnquist , V. Belov , E. P. Bernard , A. Bhat , T. Bhatta , A. Bolotnikov , P. A. Breur , J. P. Brodsky , E. Brown , T. Brunner , E. Caden , G. F. Cao , L. Cao , B. Chana , S. A. Charlebois , D. Chernyak , M. Chiu , J. R. Cohen , R. Collister , J. Dalmasson , T. Daniels , L. Darroch , R. DeVoe , M. L. di Vacri , Y. Y. Ding , M. J. Dolinski , J. Echevers , B. Eckert , M. Elbeltagi , L. Fabris , D. Fairbank , W. Fairbank , J. Farine , Y. S. Fu , G. Gallina , P. Gautam , G. Giacomini , W. Gillis , C. Gingras , R. Gornea , G. Gratta , K. Harouaka , M. Heffner , E. Hein , J. Hößl , A. House , A. Iverson , X. S. Jiang , A. Karelin , L. J. Kaufman , R. Krücken , A. Kuchenkov , K. S. Kumar , A. Larson , K. G. Leach , D. S. Leonard , G. Li , S. Li , Z. Li , C. Licciardi , R. Lindsay , R. MacLellan , J. Masbou , K. McMichael , M. Medina Peregrina , B. Mong , D. C. Moore , K. Murray , J. Nattress , C. R. Natzke , X. E. Ngwadla , K. Ni , Z. Ning , J. L. Orrell , G. S. Ortega , I. Ostrovskiy , C. T. Overman , A. Perna , T. Pinto Franco , A. Pocar , J. F. Pratte , N. Priel , E. Raguzin , G. J. Ramonnye , H. Rasiwala , K. Raymond , G. Richardson , M. Richman , J. Ringuette , P. C. Rowson , R. Saldanha , S. Sangiorgio , X. Shang , A. K. Soma , F. Spadoni , V. Stekhanov , X. L. Sun , S. Thibado , A. Tidball , J. Todd , T. Totev , O. A. Tyuka , F. Vachon , V. Veeraraghavan , S. Viel , K. Wamba , Y. Wang , Q. Wang , W. Wei , L. J. Wen , U. Wichoski , S. Wilde , W. H. Wu , W. Yan , L. Yang , O. Zeldovich , J. Zhao , T. Ziegler

Dual-phase xenon TPC detectors are a highly scalable and widely used technology to search for low-energy nuclear recoil signals from WIMP dark matter or coherent nuclear scattering of $\sim$MeV neutrinos. Such experiments expect to measure…

We measure the liquid argon scintillation response to electronic recoils in the energy range of $2.82$ to $1274.6~{\rm keV}$ at null electric field. The single-phase detector with a large optical coverage used in this measurement yields…

Instrumentation and Detectors · Physics 2020-11-25 M. Kimura , K. Aoyama , M. Tanaka , K. Yorita

Liquid xenon-based direct detection dark matter experiments have recently expanded their searches to include high-energy nuclear recoil events as motivated by effective field theory dark matter and inelastic dark matter interaction models,…

We present new measurements of the scintillation and ionization yields in liquid xenon for low energy electronic (about 3--7 keV$_{ee}$) and nuclear recoils (about 8--20 keV$_{nr}$) at different drift fields from 236 V/cm to 3.93 kV/cm,…

Instrumentation and Detectors · Physics 2015-08-19 Qing Lin , Jialing Fei , Fei Gao , Jie Hu , Yuehuan Wei , Xiang Xiao , Hongwei Wang , Kaixuan Ni

This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and light…

Instrumentation and Detectors · Physics 2017-01-25 D. S. Akerib , S. Alsum , H. M. Araújo , X. Bai , A. J. Bailey , J. Balajthy , P. Beltrame , E. P. Bernard , A. Bernstein , T. P. Biesiadzinski , E. M. Boulton , R. Bramante , P. Brás , D. Byram , S. B. Cahn , M. C. Carmona-Benitez , C. Chan , A. A. Chiller , C. Chiller , A. Currie , J. E. Cutter , T. J. R. Davison , A. Dobi , J. E. Y. Dobson , E. Druszkiewicz , B. N. Edwards , C. H. Faham , S. Fiorucci , R. J. Gaitskell , V. M. Gehman , C. Ghag , K. R. Gibson , M. G. D. Gilchriese , C. R. Hall , M. Hanhardt , S. J. Haselschwardt , S. A. Hertel , D. P. Hogan , M. Horn , D. Q. Huang , C. M. Ignarra , M. Ihm , R. G. Jacobsen , W. Ji , K. Kamdin , K. Kazkaz , D. Khaitan , R. Knoche , N. A. Larsen , C. Lee , B. G. Lenardo , K. T. Lesko , A. Lindote , M. I. Lopes , A. Manalaysay , R. L. Mannino , M. F. Marzioni , D. N. McKinsey , D. -M. Mei , J. Mock , M. Moongweluwan , J. A. Morad , A. St. J. Murphy , C. Nehrkorn , H. N. Nelson , F. Neves , K. O'Sullivan , K. C. Oliver-Mallory , K. J. Palladino , E. K. Pease , P. Phelps , L. Reichhart , C. Rhyne , S. Shaw , T. A. Shutt , C. Silva , M. Solmaz , V. N. Solovov , P. Sorensen , S. Stephenson , T. J. Sumner , M. Szydagis , D. J. Taylor , W. C. Taylor , B. P. Tennyson , P. A. Terman , D. R. Tiedt , W. H. To , M. Tripathi , L. Tvrznikova , S. Uvarov , J. R. Verbus , R. C. Webb , J. T. White , T. J. Whitis , M. S. Witherell , F. L. H. Wolfs , J. Xu , K. Yazdani , S. K. Young , C. Zhang

The dependence of the light and charge yield of liquid xenon on the applied electric field and recoil energy is important for dark matter detectors using liquid xenon time projections chambers. Few measurements have been made of this field…

Instrumentation and Methods for Astrophysics · Physics 2017-11-22 L. W. Goetzke , E. Aprile , M. Anthony , G. Plante , M. Weber

We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the…

The energy calibration of nuclear recoil detectors is of primary importance to rare-event experiments such as those of direct dark matter search and coherent neutrino-nucleus scattering. In particular, such a calibration is performed by…

Instrumentation and Detectors · Physics 2014-10-06 A. Bondar , A. Buzulutskov , A. Dolgov , E. Grishnyaev , S. Polosatkin , L. Shekhtman , E. Shemyakina , A. Sokolov
‹ Prev 1 2 3 10 Next ›