Related papers: Background Rates in Several Hard X-Ray Photon Coun…
We characterize single- and few-electron backgrounds that are observed in dual-phase liquid xenon time projection chambers at timescales greatly exceeding a maximum drift time after an interaction. These instrumental backgrounds limit a…
We report results of an experiment conducted in May 1997 to measure CdZnTe background and background reduction schemes in space flight conditions similar to those of proposed hard X-ray astrophysics missions. A 1 cm^2 CdZnTe detector was…
Small-pitch 3D silicon pixel detectors have been investigated as radiation-hard candidates for the innermost layers of the HL-LHC pixel detector upgrades. Prototype 3D sensors with pixel sizes of 50$\times$50 and 25$\times$100 $\mu$m$^{2}$…
NICER has a comparatively low background rate, but it is highly variable, and its spectrum must be predicted using measurements unaffected by the science target. We describe an empirical, three-parameter model based on observations of seven…
Suzaku Hard X-ray Detector (HXD) achieved the lowest background level than any other previously or currently operational missions sensitive in the energy range of 10--600 keV, by utilizing PIN photodiodes and GSO scintillators mounted in…
We present the operation with moderate radiation shield in a surface laboratory of BULLKID (BULky and Low-threshold Kinetic Inductance Detector), a cryogenic detector for searches of light Dark Matter or Coherent Elastic Neutrino-Nucleus…
Understanding a background is crucial in particular for a study of low surface brightness objects. In order to establish the background subtraction method, we have studied properties of the EPIC background. Count rates of the background…
The imaging and spectral performance of CdTe double-sided strip detectors (CdTe-DSDs) was evaluated for the ASTRO-H mission. The charcterized CdTe-DSDs have a strip pitch of 0.25 mm, an imaging area of 3.2 cm$\times$3.2 cm and a thickness…
In low activity gamma spectrometric measurements of large, dense samples, the bulk sample material shields the HPGe crystal from external background sources. If not accounted for in studies that utilise background-subtraction methods, this…
We propose the idea of "Earth Shielding" to reject cosmic-ray backgrounds, in the search for boosted dark matter at surface neutrino detectors, resulting in the enhancement of the signal-to-background ratio. The identification of…
In recent years, scientific Complementary Metal Oxide Semiconductor (sCMOS) devices have been increasingly applied in X-ray detection, thanks to their attributes such as high frame rate, low dark current, high radiation tolerance and low…
The sensitivity of astronomical X-ray detectors is limited by the instrumental background. The background is especially important when observing low surface brightness sources that are critical for many of the science cases targeted by…
Naturally occurring background radiation is a source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. To characterize the radiation environment in an unshielded laboratory, we…
PandaX-4T is a ton-scale dark matter direct detection experiment using a dual-phase TPC technique at the China Jinping Underground Laboratory. Various ultra-low background technologies have been developed and applied to material screening…
Low noise CCDs fully-depleted up to 675 micrometers have been identified as a unique tool for Dark Matter searches and low energy neutrino physics. The charge collection efficiency (CCE) for these detectors is a critical parameter for the…
We present an X-ray spectrum of the diffuse X-ray background (DXRB) between 1.5 and 120 keV, as measured with the Low-Energy Detector (LE) and the High-Energy Detector (HE) aboard the Insight-HXMT satellite, based on 'blank-sky'…
Micromegas detectors, thanks to the good spatial and temporal discrimination capabilities, are good candidates for rare event search experiments. Recent X-ray background levels achieved by these detectors in the CAST experiment have…
The CRESST experiment monitors 300g CaWO_4 crystals as targets for particle interactions in an ultra low background environment. In this paper, we analyze the background spectra that are recorded by three detectors over many weeks of data…
Pixel detectors are used in the innermost part of multi purpose experiments at the Large Hadron Collider (LHC) and are therefore exposed to the highest fluences of ionising radiation, which in this part of the detectors consists mainly of…
One of the key aspects of a detector material for space-borne hard X-ray and gamma-ray telescopes is the rate of prompt and delayed background events generated inside the material by charged and neutral particles striking the detector.…