Related papers: Quadrature-averaged homodyne detection for cavity …
We describe a new scheme for the measurement of mean photon flux at an arbitrary optical sideband frequency using homodyne detection. Experimental implementation of the technique requires an AOM in addition to the homodyne detector, and…
Compact interferometers, called phasemeters, make it possible to operate over a large range while ensuring a high resolution. Such performance is required for the stabilization of large instruments dedicated to experimental physics such as…
Homodyne measurement is a corner-stone of quantum optics. It measures the fundamental variables of quantum electrodynamics - the quadratures of light, which represent the cosine-wave and sine-wave components of an optical field and…
High precision metrology systems based on heterodyne interferometry can measure position and attitude of objects to accuracies of picometer and nanorad, respectively. A frequently found feature of the general system design is the…
Using only elementary calculus we prove that the balanced homodyne detector measures the quadrature phase amplitude of a signal. More precisely, after the measurement of photon numbers $l$, the collapse of the composite state of a strong…
This letter presents a dual quadrature phasemeter, an implementation of a phase-locked loop designed to track the phase of homodyne and heterodyne inter-satellite laser links. The dual quadrature phasemeters use dual quadrature optical…
A general one-dimensional quantum optical mode is described by a shape in the time or frequency domain. A fundamental problem is to measure a quadrature operator of such a mode. If the shape is narrow in frequency this can be done by pulsed…
The two output signals of quadrature phase interferometers allow to benefit both from the high sensitivity of interferometry (working inside a fringe) and from an extended input range (counting fringes). Their calibration to reach a linear…
Homodyne detection is one of the ways to circumvent the standard quantum limit for a gravitational wave detector. In this paper it will be shown that the same quantum-non-demolition effect using homodyne detection can be realized by…
We have developed a method to equip homodyne interferometers with the capability to operate with constant high sensitivity over many fringes for continuous real-time tracking. The method can be considered as an extension of the "J_1...J_4"…
We suggest an interferometric scheme assisted by squeezing and linear feedback to realize the whole class of field-quadrature quantum nondemolition measurements, from Von Neumann projective measurement to fully non-destructive…
Phase diffusion represents a crucial obstacle towards the implementation of high precision interferometric measurements and phase shift based communication channels. Here we present a nearly optimal interferometric scheme based on homodyne…
We present an analytical derivation of the coupling parameter relating the angle between two interfering beams in a heterodyne interferometer to the differential phase-signals detected by a quadrant photo-diode. This technique, also…
Discrete-modulated continuous-variable quantum key distribution with homodyne detection is widely recognized for its ease of implementation, efficiency with respect to error correction, and its compatibility with modern optical…
The extraordinary sensitivity of the output field of an optical cavity to small quantum-scale displacements has led to breakthroughs such as the first detection of gravitational waves \cite{LIGO,LIGODC} and of the motions of quantum…
We obtain the standard quadrature-phase positive operator-valued measure (POVM) for homodyne detection directly and rigorously from the POVM for photon counting without directly employing the mean field approximation for the local…
We present an electrically tunable terahertz two dimensional plasmonic interferometer with an integrated detection element that down converts the terahertz fields to a DC signal. The integrated detector utilizes a resonant plasmonic…
We present measurement schemes that do not rely on photon-number resolving detectors, but that are nevertheless optimal for estimating a differential phase shift in interferometry with either an entangled coherent state or a…
We discuss a balanced homodyne detection scheme with imperfect detectors in the framework of the operational approach to quantum measurement. We show that a realistic homodyne measurement is described by a family of operational observables…
We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and…