English
Related papers

Related papers: Signal readout for Transition-Edge Sensor X-ray im…

200 papers

Time-Division Multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in…

Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20 keV energy range. We are building a TES-based instrument for the…

Instrumentation and Detectors · Physics 2020-08-26 Tejas Guruswamy , Lisa M. Gades , Antonino Miceli , Umeshkumar M. Patel , John T. Weizeorick , Orlando Quaranta

Transition Edge Sensors (TESs) are the selected technology for future spaceborne X-ray observatories, such as Athena, Lynx, and HUBS. These missions demand thousands of pixels to be operated simultaneously with high energy-resolving power.…

The next generation of space-based mm-wave telescopes, such as JAXA's LiteBIRD mission, require focal planes with thousands of detectors in order to achieve their science goals. Digital frequency-domain multiplexing (dfmux) techniques allow…

Instrumentation and Methods for Astrophysics · Physics 2022-07-26 Graeme Smecher , Peter Cameron , Jean-Francois Cliche , Matt Dobbs , Joshua Montgomery

In the past 20 years, dual-readout calorimetry has emerged as a technique for measuring the properties of high-energy hadrons and hadron jets that offers considerable advantages compared with the instruments that are currently used for this…

Instrumentation and Detectors · Physics 2018-05-23 Sehwook Lee , Michele Livan , Richard Wigmans

Spectrograph is an optical device that is used to disperse photons of different energies $E$ into distinct directions and space locations, and to take a snapshot of the whole spectrum of photon energies with a spatially sensitive photon…

Optics · Physics 2015-06-03 Yuri Shvyd'ko

We construct a low-temperature microwave waveguide interferometer for measuring high-frequency properties of two-dimensional electron gases (2DEGs). Coupled plasmon-cyclotron resonance (PCR) spectra are used to extract effective mass, bulk…

Mesoscale and Nanoscale Physics · Physics 2017-04-26 Jie Zhang , Ruiyuan Liu , Rui-Rui Du , L. N. Pfeiffer , K. W. West

Large arrays of cryogenic sensors for various imaging applications ranging across x-ray, gamma-ray, Cosmic Microwave Background (CMB), mm/sub-mm, as well as particle detection increasingly rely on superconducting microresonators for high…

We present two variants of a magnetic microcalorimeter with paramagnetic temperature sensors and integrated dc-SQUID readout for high-resolution X-ray emission spectroscopy. Each variant employs two overhanging gold absorbers with a…

Instrumentation and Detectors · Physics 2024-01-24 Matthäus Krantz , Francesco Toschi , Benedikt Maier , Greta Heine , Christian Enss , Sebastian Kempf

The flight of the Micro-X sounding rocket on July 22, 2018 marked the first operation of Transition-Edge Sensors and their SQUID readouts in space. The instrument combines the microcalorimeter array with an imaging mirror to take…

The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise…

Calorimeters will provide critical measurements at future collider detectors. As the traditional challenge of high dynamic range, high precision, and high readout rates for signal amplitudes is compounded by increasing granularity and…

Instrumentation and Detectors · Physics 2022-04-04 Timothy Andeen , Julia Gonski , James Hirschauer , James Hoff , Gabriel Matos , John Parsons

Image sensors with nondestructive charge readout provide single-photon or single-electron sensitivity, but at the cost of long readout times. We present a smart readout technique to allow the use of these sensors in visible-light and other…

Instrumentation and Methods for Astrophysics · Physics 2021-12-15 Fernando Chierchie , Guillermo Fernandez Moroni , Leandro Stefanazzi , Eduardo Paolini , Javier Tiffenberg , Juan Estrada , Gustavo Cancelo , and Sho Uemura

We introduce a frequency-multiplexed readout scheme for superconducting phase qubits. Using a quantum circuit with four phase qubits, we couple each qubit to a separate lumped-element superconducting readout resonator, with the readout…

In this paper we explore the application of cryogenic imaging spectrophotometers. Prototypes of this new class of detector, such as superconducting tunnel junctions (STJs) and transition edge sensors (TESs), currently deliver low resolution…

Astrophysics · Physics 2009-10-31 Ben A. Mazin , Robert J. Brunner

The measurement of shifts in the energy of X-ray emission lines is important for understanding the electronic structure and physical properties of materials. In this study, we demonstrate a method using a synchrotron source to introduce…

Instrumentation and Detectors · Physics 2025-02-19 Tejas Guruswamy , Orlando Quaranta , Lisa Gades , Umeshkumar Patel , Antonino Miceli

High-resolution pionic-atom x-ray spectroscopy was performed with an x-ray spectrometer based on a 240-pixel array of superconducting transition-edge-sensor (TES) microcalorimeters at the piM1 beam line of the Paul Scherrer Institute.…

We are developing the frequency domain multiplexing (FDM) read-out of transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field Unit (X-IFU) instrument on board of the future European X-Ray observatory Athena. The X-IFU…

Various chips for the silicon sensors measurements are described. These chips are based on 0.35 um and 0.18um CMOS technology. Several analog chips together with self-trigger /derandomizer one allow to measure silicon sensors designed for…

Instrumentation and Detectors · Physics 2009-10-13 E. Atkin , A. Kluev , A. Silaev , A. Fedenko , D. Karmanov , M. Merkin , A. Voronin

Transition-edge sensors (TES) are photon-number resolving calorimetric spectrometers with near unit efficiency. Their recovery time, which is on the order of microseconds, limits the number resolving ability and timing accuracy in high…

Instrumentation and Detectors · Physics 2018-12-21 Jianwei Lee , Lijiong Shen , Alessandro Cerè , Thomas Gerrits , Adriana E. Lita , Sae Woo Nam , Christian Kurtsiefer
‹ Prev 1 3 4 5 6 7 10 Next ›