Related papers: Sharp dose profiles for high precision proton ther…
Purpose: To quantitatively compare the dosimetric and biologic differences in treatment plans from flattened and flattening-filter-free (FFF) beam for three anatomic cancer sites. Methods and Materials: Treatment plans with static…
An efficient scheme of generating ultra-tightly focused proton bunch with radius in nanometer scale is proposed. A needlelike proton filament of transverse size in nanometer scale with the density of and charge quantity is obtained based on…
Objective. Prompt-gamma imaging encompasses several approaches for online monitoring of beam range or deposited dose distribution in proton therapy. We test one of the imaging techniques - a coded mask approach - both experimentally and via…
Temporally modulated pulsed radiotherapy (TMPRT) delivers conventional fraction doses of radiation using temporally separated pulses of low doses (<30 cGy) yielding fraction-effective dose rates of around 6.7 cGy/min with the goal to…
With the advancement of treatment modalities in radiation therapy for cancer patients, outcomes have improved, but at the cost of increased treatment plan complexity and planning time. The accurate prediction of dose distributions would…
This work addresses computing techniques for dose calculations in treatment planning with proton and ion beams, based on an efficient kernel-convolution method referred to as grid-dose spreading (GDS) and accurate heterogeneity-correction…
We theoretically investigate high energy, collimated proton beam with three dimensional particle in cell simulations of ultrashort petawatt laser interaction with cryogenic hydrogen target of various shapes. Here we show that under…
Purpose: To demonstrate a proton imaging system based on well-established fast scintillator technology to achieve high performance with low cost and complexity, with the potential of a straightforward translation into clinical use. Methods:…
We used the GEANT4 Monte Carlo MC Toolkit to simulate carbon ion beams incident on water, tissue, and bone, taking into account nuclear fragmentation reactions. Upon increasing the energy of the primary beam, the position of the Bragg-Peak…
We summarize recent results and ongoing activities in mathematical algorithms and computer science methods related to proton computed tomography (pCT) and intensity-modulated particle therapy (IMPT) treatment planning. Proton therapy…
We developed a novel method of creating intensity modulated proton arc therapy (IMPAT) plans that uses computing resources efficiently and may offer a dosimetric benefit for patients with ependymoma or similar tumor geometries. Our IMPAT…
Stereotactic body radiotherapy (SBRT) is characterized by delivering a high amount of dose in a short period of time. In SBRT the dose is delivered using open fields (e.g., beam's-eye-view) known as "apertures". Mathematical methods can be…
Laser-driven proton sources have long been developed with an eye on their potential for medical application to radiation therapy. These sources are compact, versatile, and show peculiar characteristics such as extreme instantaneous dose…
Objective: To assess the accuracy and computational performance of a stochastic differential equation (SDE)--based model for proton beam dose calculation by benchmarking against Geant4 in simplified phantom geometries. Approach: Building on…
Purpose: In treatment planning of charged-particle radiotherapy, patient heterogeneity is conventionally modeled as variable-density water converted from CT images to best reproduce the stopping power, which may lead to inaccuracies in the…
Heavy ions have varying effects on the target. The most important factor in comparing this effect is Linear Energy Transfer (LET). Protons and carbons are heavy ions with high LET. Since these ions lose energy through collisions as they…
Intense laser-driven proton pulses, inherently broadband and highly divergent, pose a challenge to established beamline concepts on the path to application-adapted irradiation field formation, particularly for 3D. Here we experimentally…
In this work, the standard CsI(Tl) scintillator was used to determine the characteristics of a proton beam. By irradiating the scintillator with a proton beam, it was able to subsequently measure the emitted light using a spectrometer. This…
Purpose: Highlight the distinctions, both in terms of concept and numerical values, of the various definitions that can be established for the dose rate in PBS proton therapy. Methods: In an in silico study, five definitions of the dose…
We propose to develop deep learning models that can predict Pareto optimal dose distributions by using any given set of beam angles, along with patient anatomy, as input to train the deep neural networks. We implement and compare two deep…